  • Page 1 CLGOGUIT4 3663602842170 V10617 TRAG10583 - 200000009 - Cooke and Lewis 4 Burner Gas on Glass v3b Rv2.indd 1 13/06/2017 16:17...
  • Page 2 IMPORTANT - Please read carefully the separate safety guide before use. [02] x1 [03] x2 [04] x1 [05] x2 [06] x1 [07] x4 [01] x1 [08] x1 [09] x4 [10] x4 [11] x4 [12] x4 (G2.350 13 mbar) (G30 37 mbar) (G31 37 mbar) (4 x 25mm) TRAG10583 - 200000009 - Cooke and Lewis 4 Burner Gas on Glass v3b Rv2.indd 2...
  • Page 3 Installation TRAG10583 - 200000009 - Cooke and Lewis 4 Burner Gas on Glass v3b Rv2.indd 3 13/06/2017 16:17...
  • Page 4 Installation Caution: The connection of the hob to the gas network or gas cylinder must be made by means of a rigid copper or steel pipe with fittings complying with local regulations. These fittings are NOT supplied. THIS OPERATION MUST BE MADE BY A QUALIFIED GAS INSTALLER NOTE: •...
  • Page 5 ≥760mm ≥150mm >55mm ≥150mm Warning: Good ventilation is required around the appliance for easier dissipation of heat and low power consumption. Sufficient clearance is required around the appliance as shown in the diagrams above. The gap between the hob and any cupboard or extractor above it must be at least 760mm. TRAG10583 - 200000009 - Cooke and Lewis 4 Burner Gas on Glass v3b Rv2.indd 5 13/06/2017 16:17...
  • Page 6 [08] x1 Cut an aperture in the worktop using a jigsaw as shown. The worktop should be at least 30mm thick and made of a heat resistant material. TRAG10583 - 200000009 - Cooke and Lewis 4 Burner Gas on Glass v3b Rv2.indd 6 13/06/2017 16:17...
  • Page 7 Seal the cut edge of the worktop using silicone sealant or PVA adhesive. IMPORTANT: ensure that either product is fully cured as per the manufacturer’s instructions before you commence installation of the hob. This hob MUST NOT be sealed or bonded into the worktop. TRAG10583 - 200000009 - Cooke and Lewis 4 Burner Gas on Glass v3b Rv2.indd 7 13/06/2017 16:17...
  • Page 8 [06] x1 [06] Stretch out the supplied seal along the underside edge of the hob, ensuring the ends overlap. TRAG10583 - 200000009 - Cooke and Lewis 4 Burner Gas on Glass v3b Rv2.indd 8 13/06/2017 16:17...
  • Page 9 [01] [01] x1 Once the worktop edge has cured, and the tape is fitted, position the hob into the cutout in the worktop. TRAG10583 - 200000009 - Cooke and Lewis 4 Burner Gas on Glass v3b Rv2.indd 9 13/06/2017 16:17...
  • Page 10: Connection To The Gas Supply

    +45mm 20-45mm [07] x4 [07] [07] [12] [12] x4 Secure the hob to the worktop by attaching the brackets as shown. Connection to the gas supply THE CONNECTION TO THE GAS SUPPLY MUST ONLY BE MADE BY A QUALIFIED GAS INSTALLER •...
  • Page 11 Adjustment to a different type of gas Caution: replacement of gas jets must only be carried out by a qualified gas installer. Note: Extra gas jets are supplied to enable conversion for use with different gas types including liquid petroleum gas (LPG) butane and propane. Details of the extra jets supplied and their applications can be found in the Injector Table printed later in this manual.
  • Page 12: Connecting To The Electrical Supply

    Connecting to the electrical supply All installation must be carried out by a qualified electrician. Before connecting the mains supply ensure that the mains voltage corresponds to the voltage on the rating plate. Direct Connection The appliance must be connected directly to the mains using an omnipolar circuit breaker with a minimum opening of 3 mm between the contacts.
  • Page 13: Before You Start

    Before you start Switch on the appliance at the switched fused connection unit. The appliance is ready for use. WARNING: Read the instructions before using the appliance. Functions and settings • Flame safety device (FSD): Stops the gas supply to the gas hob when the flame goes out. •...
  • Page 14: Operation

    Type of gas used Model Rated thermal Total rated configuration flowrate consumption 4 BURNERS (kW) G20 20 mbar 1AUX – 2SR – 1R 7.35 701 lt/h G30 28-30 mbar 1AUX – 2SR – 1R 7.10 516 g/h G31 37 mbar 1AUX –...
  • Page 15 Care & maintenance Warning: Always switch off the electricity and gas supply before performing maintenance work. In the event of a fault, contact customer services at the end of the care and maintenance section. Caution: • Use soapy water and a cloth for cleaning. Never use abrasive powders. •...
  • Page 16 Manufacturer: Kingfisher International Products Limited, 3 Sheldon Square, London, W2 6PX, United Kingdom Distributor: B&Q plc, Chandlers Ford, Hants, SO53 3LE United Kingdom www.diy.com SFD Limited, Trade House, Mead Avenue, Yeovil, BA22 8RT, United Kingdom TRAG10583 - 200000009 - Cooke and Lewis 4 Burner Gas on Glass v3b Rv2.indd 16 13/06/2017 16:17...
  • Page 17 TRAG10583 - 200000009 - Cooke and Lewis 4 Burner Gas on Glass v3b Rv2.indd 17 13/06/2017 16:17...
  • Page 18 TRAG10583 - 200000009 - Cooke and Lewis 4 Burner Gas on Glass v3b Rv2.indd 18 13/06/2017 16:17...
  • Page 19 TRAG10583 - 200000009 - Cooke and Lewis 4 Burner Gas on Glass v3b Rv2.indd 19 13/06/2017 16:17...
  • Page 20 TRAG10583 - 200000009 - Cooke and Lewis 4 Burner Gas on Glass v3b Rv2.indd 20 13/06/2017 16:17...

This manual is also suitable for:

Clgoguit4

Table of Contents