Arbitrary Waveform Generators
Declassification and Security
071-2086-00
Revision B
www.tektronix.com
071208600
071208600

Advertisement

loading
Need help?

Need help?

Do you have a question about the AWG5012 and is the answer not in the manual?

Questions and answers

Summary of Contents for Tektronix AWG5012

  • Page 1 Instructions AWG5000 Series Arbitrary Waveform Generators Declassification and Security 071-2086-00 Revision B www.tektronix.com 071208600 071208600...
  • Page 2 Copyright © Tektronix. All rights reserved. Licensed software products are owned by Tektronix or its subsidiaries or suppliers, and are protected by national copyright laws and international treaty provisions. Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supercedes that in all previously published material.
  • Page 3: Table Of Contents

    Table of Contents Preface ............. Clear and Sanitize Procedures .
  • Page 4 Table of Contents AWG5000 Series Declassification and Security...
  • Page 5: Preface

    AWG5004 and all options AWG5000 Series Arbitrary Waveform Generators Service Manual, Tektronix Related Documents part number 071-2083-XX, available on the Tektronix Web site at www.tektronix.com/manuals AWG5000 Series Arbitrary Waveform Generators Hard Disk Drive Assembly Installation Instructions, Tektronix part number 075-0927-XX, available on the Tektronix Web site at www.tektronix.com/manuals...
  • Page 6 Preface The following terms may be used in this document: Terms Clear. This removes data on media/memory before reusing it in a secured area. All reusable memory is cleared to deny access to previously stored information by standard means of access. Erase.
  • Page 7: Clear And Sanitize Procedures

    Clear and Sanitize Procedures Memory Devices The following tables list the volatile and nonvolatile memory devices. Table 1: Volatile memory devices Type and User minimum size Function modifiable Data input method Location Process to clear DDR2 SRAM Microprocessor Written by processor Micro-ATX board Remove the power source 64 M x 64 bits...
  • Page 8 Clear and Sanitize Procedures The following instructions give a method to disable the built-in USB and CD-RW Disabling USB and CD-RW capability. Using the BIOS disables the devices for DOS programs, while the Capability Windows Device Manager disables the devices for Windows programs. These procedures disable both USB and the CD-RW to prevent their use.
  • Page 9 Clear and Sanitize Procedures 1. Press F2 during instrument Boot Up to go to the BIOS configuration menu. To Disable LAN Ethernet Connectivity Using the 2. Go to Advanced > Peripheral Configuration. BIOS 3. Set Onboard LAN to Disabled. 4. Press Esc one time to return to the main BIOS configuration menu. 5.
  • Page 10 Removable Hard Drive instrument user online help (AWG Reference > Removable Hard Disk). You can also refer to the AWG5000 Series HDD Installation Instructions, Tektronix part number 075-0927-XX. All user-storable data is stored on the rear-panel removable hard drive. There are DOD-approved scrubbing software packages available for the hard drive.
  • Page 11: Media Storage And Data Export Devices

    Table 2. Additional removable hard drives (Tektronix part number 065-0768-00) can be purchased from Tektronix. If the hard drive has been removed and a new hard drive is installed, you need to install the operating system and instrument application software.
  • Page 12: Troubleshooting

    If your instrument is not functioning, proceed as follows. Refer to your organization’s policies regarding storage or disposal of any removed items. Remove the hard disk drive before returning the instrument to Tektronix for repair. Hard Disk Drive Remove all CDs and DVDs.