Arm Type Blood Pressure Monitor Model: BPM82 INSTRUCTION MANUAL PLEASE READ THIS INSTRUCTION MANUAL COMPLETELY BEFORE OPERATING THIS UNIT RoHS REACH MDSS GmbH Schiffgraben 41 30175 Hannover Germany AViTA Corporation 9F., No. 78, Sec. 1, Kwang Fu Rd., San Chung Dist., New Taipei City 24158, Taiwan...
Contents Intended Use........................1 Type of Use/ Reuse ......................1 Intended User ........................1 Important Information before Use ................3 Product Identification ..................... 5 Description of LCD Display ................... 6 Battery Installation ......................7 Setting the Date and Time .................... 8 Placement of the Pressure Sleeve................
Intended Use The BPM82 automatically measures human begins Systolic, Diastolic blood pressure and pulse rate by oscillometric method. The measurement results are displayed on the LCD. Measurement position is at human being's upper arm. The intended use of this over-the-counter device is for adults with upper arm circumference ranging from 220 mm to 420 mm (Approx.
Page 4
Warnings • Do not use with pregnant or pre-eclamptic patients • Regarding the effect of blood flow interference and resulting harmful injury to the patient caused by continuous cuff pressure due to connection tubing kinking. • Regarding the information that pressurization of the cuff can temporarily cause loss of function of simultaneously used monitoring ME equipment on the same limb.
Important Information before Use 1. Blood pressure measurements should only be interpreted by a physician or a trained health care professional who is familiar with your medical history. Through regular use of this device and recording of your measurements, you can keep your physician informed of the changes in your blood pressure.
Page 6
For Customer Service, It is recommended that the accuracy should be checked by manufacture every 2 years. To obtain the service please contact AViTA Corp. for the address of the repair location. Enclose the Proof of Purchase. Include $10.00 USD for the return shipping and handling.
Description of LCD Display Low battery indicator WHO indicator Date & Time Irregular Heartbeat Symbol AF Symbol Memory Symbol Memory Set Heartbeat Symbol Pulse rate Release air Systolic Pressure Diastolic Pressure...
Battery Installation Low battery warning: It is necessary to replace the batteries when the Low Battery symbol “ ” appears on the display, or when the display does not turn on after the POWER key is pressed. Replacing the Battery:: 1.
Setting the Date and Time It is necessary to set the date and time for the unit every time batteries are initially installed or replaced. To set the date and time, proceed as follows: • While in power off mode, press and hold the “+” key for at least 3 seconds to enter Date and Time setting procedure and the Year value will begin to flash.
Placement of the Pressure Sleeve It is important to avoid smoking, eating, taking medication, alcohol consumption or physical activity 30 minutes prior to taking a reading. If for any reason you are unable to or should not use your left arm, please modify the instructions for cuff application to your right arm.
Page 12
6. Insert your left arm into the created cuff cylinder. 7. The bottom edge of the cuff should be positioned approximately one inch above the elbow joint. 8. Reaching underneath your left arm with your right hand, pull the end of the cuff towards your body to tighten the cuff.
Measurement of Pulse Rate and Blood Pressure To set the user and memory zone, proceed as follows: While in power off mode, press the “+” key or “-” key to select user. Confirm your selection with the Power key to turn the power on and start to measure your blood pressure.
5. To detect the heartbeat, the heartbeat symbol will appear and continuous flashes on the LCD display. 6. Your blood pressure measurement and pulse will display simultaneously on the screen. 7. The Hypertension Indicator will indicate your reading range on the display separately.
Irregular Heartbeat Detector Your digital blood pressure monitor features an Irregular Heartbeat Detector. This feature allows users to accurately monitor blood pressure even if an irregular heartbeat should occur. When an irregular heartbeat “ ”is detected, the icon will appear on the display. Note: Please consult with your physician or trained healthcare professional for further information regarding an irregular heartbeat and if this symbol...
Atrial Fibrillation (AFIB) This device is a blood pressure monitor that also analyses heart rate variability during measurement. While in power off mode, switch the “AF” key to select AF mode “ON” or “OFF”. After measurement mode setting, press the “+” key or “-”...
Memory Function Recalling Measurements in Memory: You can recall up to 100 measurements for each user, plus those average values stored measurements in memory to share with your physician or trained healthcare professional. If you press the M key, the unit will first display the average of last 3 currently stored measurements.
Page 18
stored measurements Clearing Measurements from Memory: From the memory mode, press and hold down the M key until the display shows CLr. This indicates that all measurements have been erased.
Error Codes Err Code Meaning Corrective Action No pulse or detect Take off heavy clothes and Err 00 pulses not enough. retry again. The Arm cuff is not fastened The cuff is not properly. Re- apply the cuff, Err 01 fastened correctly and take a measurement again.
Troubleshooting Problem Probable Cause Recommended Action Nothing appears in Batteries are drained. Replace all batteries with the display even new ones. when the power is Battery are not correctly Reinsert batteries in the turned on. aligned with terminals. correct position. Low Battery Batteries are drained.
Cleaning and Disinfecting • Clean your blood pressure monitor carefully using a slightly damp cloth only. • Do not use any detergents or solvents. • Never hold the instrument under water as otherwise liquid can penetrate and damage the instrument •...
EMC Tables BPM82 is intended for use in the electromagnetic environment specified below. The customer or the user of BPM82 must make sure that it is used in such an environment. Guidance and manufacturer’s declaration - Electromagnetic emissions Professional healthcare...
Page 24
requested from supplier using the contact information provided in this manual. However, it is advisable to keep the electromechanical aerosol equipment at an adequate distance of, at least, 0.5 m from mobile phones or other RF communications transmitters to minimise possible interference.
Explanation of Symbols Symbol Definition The CE marking with the Registration Number of the Notified Body. This denotes the compliance of Regulation (EU) 2017/745 Medical Device Manufacturer Authorized representative in the European Community Date of manufacture (YYYY-MM-DD or YYYY-MM) Batch code (YYMMWWWW) Serial number (YYMWWWXXXXX)
Page 26
Humidity limitation Atmospheric pressure limitation Caution Consult the instruction for use Disposal information: Should you wish to dispose of the article, do so in accordance with current regulations. Details are available from your local authority. WEEE 2012/19/EU Directives This product fulfilling the requirements of the RoHS Directive RoHS 2011/65/EU.
Page 27
This product meets the basic safety and essential performance requirements indicated in the IP22 conditioning test (protection against solid foreign objects of 12.5mm ∅ and greater and against vertically falling water drops when enclosure tiled up to 15°) The empty, completely flat batteries must be disposed of through specially designated collection boxes, recycling points or electronics retailers.