Please isolate mains prior to installation or maintenance
Check the total load on the circuit (including when this luminaire is fitted) d
the circuit cable, fuse or circuit breaker
Please note the IP (Ingress Protection) rating of this product when decidin
This product is Class I and must be earthed
This product is IP54 rated

INSTALLATION

Note - If this luminaire is being used in conjunction with an external PIR or sensor,
manufacturer of the sensors that they are compatible with the lamps being used
Provide power to the required point of installation. Suitable IP rated junctio
where required
Round cable should be used for the mains supply. The use of flat cable wi
fitting
Remove the baseplate from the luminaire by loosening the screws on eithe
Using the baseplate as a template, mark the location for, and drill the fixing
infringe with any gas/water pipes or electrical cables
Feed the mains cable through the rubber grommet to retain IP rating
Fix the baseplate using the screws and wall plugs provided (see Fig. 1)