Page 1
Stanley Part Number 204066 REV D2 10.21.2015 Copyright 2015, Stanley Security Solutions. Prohibition on Copying: Any unauthorized reproduction, disclosure or distribution of copies by any person of any portion of this work may be a violation of copyright law of the United States of America and other countries, could result in the awarding of statutory damages of up to $250,000 (17 USC 504) for infringement, and may result in further civil and criminal penalties.
MC521 PRO Control Box : If a solenoid lock is installed with no lock circuit board (new style), set Lock Logic to the actual Solenoid Lock lock type (Fail Safe or Fail Secure). If a Fail Safe or Fail Secure Lock is being installed with a lock circuit board (old style), the Lock Logic must be set to Fail Secure.
Page 6
MC521 PRO Control Box Step 4 : Select applicable Switch Type Motor Step 3 : Select Duraglide , and Setup Motor Handing Step 6 Step 5 : If additional configuration is needed, : Configure additional settings and press press after each setting has been UPDATE CONFIGURE DOOR changed.
Page 7
MC521 PRO Control Box Step 10 : For all doors except cart doors press Step 9 : Put door fuction switch to Hold Open to operate and have door(s) MOTOR 1 then immediately back to . The Closed move. For cart doors, press MOTOR 2 same function can be done remotely when configuring the second door.
MC521 PRO Control Box Step 16 Step 15 : Press to view all current : Review the information on the SUMMARY settings. listing. Summary Tuning In the MC521 Pro Controller Using the Controller Pushbuttons NOTE: 1. To change the INDEX Hold switch while pressing to get to desired...
Page 9
MC521 PRO Control Box Table 1. FIS Procedure using Pushbuttons Step Description Display Index Value Status Code Set Function switch to Closed Turn power on. Unlock keypad. Restart Select door type: Slide, 01 single motor or 02 dual motor. 01 (single) 02 (dual) Select handing: 00 Right or 01 Left.
Page 10
MC521 PRO Control Box Table 3. Settings Index Min. Description Defaults Value Value Single Dual Open speed, increment by 1. Close speed, revolutions per second. Check speed, revolutions per second. Open check length. Close check length. Reduced open position, percent of full opening (00=full open, 99=full close). Hold open delay (0 to 25 sec.).
Page 11
MC521 PRO Control Box Table 4. Status Codes Status Code Description Remediation IF Necessary Normal operation—All OK Obstruction Breakout System error See attachment 7 Internal Communication Error – Type 1 See attachment 7 Motor Drive Failure Replace Controller Internal Communication Error – Type 2 See attachment 7 First installation sequence (FIS) Auto-configuration sequence...
Threshold Sensor Installation and Operation,” and TUNE-IN Stanguard threshold sensor. 3. IF SU-100 motion sensor(s) are installed, refer to Stanley Access Technologies document No. 203957, “SU-100 Motion Sensor Installation and Operation,” and TUNE-IN SU-100 motion sensor(s). 4. IF OA-203C presence sensor(s) are installed, refer to manufacturer’s instructions and TUNE-IN OA-203C presence sensor(s).
MC521 PRO Control Box Table 6. Spare Parts List Description Part Number MC521 Pro Controller, includes 4 terminal blocks 314117 MC521 Pro Controller Manual 204066 Harness, Rocker Switch to Control Box, 98 inches 414098 Harness, Rocker Switch to Control Box, 180 inches 414099 Harness, Holding Beam to Control Box, 24 inches 414106...
MC521 PRO Control Box Attachment 1 MC521 Pro Controls and Indicators (Sheet 1 of 2) SEE DETAIL A DETAIL A NOTE: See next page for indicators and descriptions Document # 204066 REV D2 • www.stanleyaccesstechnologies.com • 1.800.7.ACCESS...
Page 15
MC521 PRO Control Box Attachment 1 MC521 Pro Controls and Indicators (Sheet 2 of 2) ITEM CONTROL/INDICATOR DESCRIPTION Motor 2 Connector P402 Motor No. 2 connector. Connection point for incoming line, neutral, and common Power Connector J500 power wiring. Fuse F500 Controller fuse-- 5 Amp, 250V Motor 1 Connector P401 Motor No.
MC521 PRO Control Box Attachment 2 MC521 Pro System Wiring Diagram (Sheet 1 of 6) Document # 204066 REV D2 • www.stanleyaccesstechnologies.com • 1.800.7.ACCESS...
Page 17
MC521 PRO Control Box Attachment 2 MC521 Pro System Wiring Diagram (Sheet 2 of 6) 1.800.7.ACCESS • www.stanleyaccesstechnologies.com • Document # 204066 REV D2...
Page 18
MC521 PRO Control Box MC521 PRO Control Box Attachment 2 MC521 Pro System Wiring Diagram (Sheet 3 of 6) Document # 204066 REV D2 • www.stanleyaccesstechnologies.com • 1.800.7.ACCESS Document # 204066 REV D • www.stanleyaccesstechnologies.com • 1.800.7.ACCESS...
Page 19
MC521 PRO Control Box Attachment 2 MC521 Pro System Wiring Diagram (Sheet 4 of 6) 1.800.7.ACCESS • www.stanleyaccesstechnologies.com • Document # 204066 REV D2...
Page 20
MC521 PRO Control Box Attachment 2 MC521 Pro System Wiring Diagram (Sheet 5 of 6) COLOR DUAL HOLDING BEAM WIRING OUTPUT UPPER RECEIVER (-) UPPER RECEIVER OUTPUT LOWER RECEIVER (-) LOWER RECEIVER TRANSMITTER CONTROL LOWER AND UPPER NO CONNECTION NO CONNECTION (+) ALL RECEIVERS AND TRANSMITTERS (-) LOWER AND UPPER TRANSMITTERS, JUMPER TO TB6-10 JUMPER FROM TB6-9...
Page 21
MC521 PRO Control Box Attachment 2 MC521 Pro System Wiring Diagram (Sheet 6 of 6) COLOR DUAL HOLDING BEAM WIRING JUMPER FROM TB6-3 NO CONNECTION YL, WH OUTPUT RECEIVER, JUMPER FROM TB6-1 (-) RECEIVER TRANSMITTER CONTROL NO CONNECTION NO CONNECTION (+) RECEIVER AND TRANSMITTER (-) TRANSMITTER, JUMPER TO TB6-10 JUMPER FROM TB6-9...
MC521 PRO Control Box Attachment 3 MC521 Pro Terminal Block Connections -- TB1 through TB7 (Sheet 1 of 1) Document # 204066 REV D2 • www.stanleyaccesstechnologies.com • 1.800.7.ACCESS...
Page 23
MC521 PRO Control Box Attachment 4 ANSI/BHMA and UL Compliance Requirements for Sliding Doors (Sheet 1 of 2) Final adjustment and proper operation of the door system must be and shall be performed in the field. NOTE : These instructions are for informational purposes and do not substitute for review against the current revision of the referenced standards.
Page 24
MC521 PRO Control Box Attachment 4 ANSI/BHMA and UL Compliance Requirements for Sliding Doors (Sheet 2 of 2) To ensure that a sliding door operates in accordance with UL 325 entrapment protection criteria the following must be established: • Manual opening force (sliding doors without breakout) or breakout force with power on or off must be less then 50 lbf (222.4 N).
MC521 PRO Control Box Attachment 5 -- Handheld Device Troubleshooting Aid (Sheet 1 of 1) Terminal and Pin Description State TB1-8 Solenoid Lock Output Dark = Unlocked w/o PCB, fail secure Dark = Unlocked w/o PCB, fail safe Dark = Locked Rotary Function Switch States for TB2 Hold Closed...
MC521 PRO Control Box Attachment 6 Handheld Device Troubleshooting Screen Descriptions (Sheet 1 of 1) TB1-8 Swing = Bodyguard Data Line Output or Lock Output Slide = Solenoid Lock Output TB2-1 Swing/Slide = Hold Open Function Switch Input TB2-3 Swing/Slide = Automatic Function Switch Input TB2-5 Slide = Enter/One Way Switch Input TB2-7 Slide = Reduced Open Switch Input TB2-9 Slide = Reduced Open/One Way Single Pole Rotary Input...
MC521 PRO Control Box Attachment 7 MC521 Pro Troubleshooting Aid (Sheet 1 of 1) Symptom Remedy Use best practices to troubleshoot using handheld device and provided wiring diagrams. Check hold beam type (index 20) Optex hold beams should Door does not close and/or be set to “Optex”...
MC521 PRO Control Box Attachment 8 Recommended Values for Different/Weights Types of Slide Door Index Description Slide Doors 125 LB 350 LB 100 LB 600 LB Dura-Max Single Motor Single Motor Single Motor Double Diamond Single Slide Bi-Part - LPH Bi-part or Equiv.
Fine Tuning Slide Doors (Sheet 1 of 2) Tuning the Stanley Automatic Door Match your actual door to one from the list of doors described in the attachment. Start by installing these settings. Use the guide below to make adjustments to these settings.
Page 30
Attachment 9 Fine Tuning Slide Doors (Sheet 2 of 2) Tuning the Stanley Automatic Door (Continued). Match your actual door to one from the list of doors described in the attachment. Start by installing these settings. Use the guide below to make adjustments to these settings.