Advertisement

MC521 Pro Controller
Installation and Operation Manual
204066
INCLUDES INSTRUCTIONS FOR
DURA-GLIDE™ 2000/3000, 5200/5300,
DURA-GUARD™ DURA-STORM™ AND DURA-MAX™ 5400-SERIES
AUTOMATIC SLIDE DOOR SYSTEMS
Stanley Part Number 204066
REV D2 10.21.2015
Copyright 2015, Stanley Security Solutions.
Prohibition on Copying: Any unauthorized reproduction, disclosure or distribution of copies by
any person of any portion of this work may be a violation of copyright law of the United States
of America and other countries, could result in the awarding of statutory damages of up to
$250,000 (17 USC 504) for infringement, and may result in further civil and criminal penalties.
All rights reserved.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Pro MC521 and is the answer not in the manual?

Questions and answers

Summary of Contents for Stanley Pro MC521

  • Page 1 Stanley Part Number 204066 REV D2 10.21.2015 Copyright 2015, Stanley Security Solutions. Prohibition on Copying: Any unauthorized reproduction, disclosure or distribution of copies by any person of any portion of this work may be a violation of copyright law of the United States of America and other countries, could result in the awarding of statutory damages of up to $250,000 (17 USC 504) for infringement, and may result in further civil and criminal penalties.
  • Page 2: Table Of Contents

    Table of Contents General Description ......................2 Intended Use ............................. 2 Applicability ............................... 2 Prerequisites .............................. 3 Precautions..............................3 Installation Instructions ....................3 Installing the MC521 Pro Controller ....................3 Wiring Instructions ......................3 Evaluating Power Requirements ......................3 Connecting Main Power Wiring ......................4 Connecting Accessories (As Applicable) ..................
  • Page 3: Prerequisites

    • Stanley Access Technologies document No. 203975, “Stan Vision Installation and Operation” (if installed). • Stanley Access Technologies document No. 203957, “SU-100 Motion Sensor Installation and Operation” (if installed). • SU-100 tune-in remote control (if SU-100 Motion Sensor is installed).
  • Page 4: Connecting Main Power Wiring

    • Stanguard threshold sensor • Doorway holding beam • Breakout switch • Solenoid lock • SU-100 motion sensor(s) wiring (refer to Stanley Document #203957) • OA-203C presence sensor(s) wiring • Push plate wiring • Door position switch closed contact (with door closed) •...
  • Page 5: Tuning In The Mc521 Pro Controller Using A Handheld Device

    MC521 PRO Control Box : If a solenoid lock is installed with no lock circuit board (new style), set Lock Logic to the actual Solenoid Lock lock type (Fail Safe or Fail Secure). If a Fail Safe or Fail Secure Lock is being installed with a lock circuit board (old style), the Lock Logic must be set to Fail Secure.
  • Page 6 MC521 PRO Control Box Step 4 : Select applicable Switch Type Motor Step 3 : Select Duraglide , and Setup Motor Handing Step 6 Step 5 : If additional configuration is needed, : Configure additional settings and press press after each setting has been UPDATE CONFIGURE DOOR changed.
  • Page 7 MC521 PRO Control Box Step 10 : For all doors except cart doors press Step 9 : Put door fuction switch to Hold Open to operate and have door(s) MOTOR 1 then immediately back to . The Closed move. For cart doors, press MOTOR 2 same function can be done remotely when configuring the second door.
  • Page 8: Tuning In The Mc521 Pro Controller Using Pushbuttons

    MC521 PRO Control Box Step 16 Step 15 : Press to view all current : Review the information on the SUMMARY settings. listing. Summary Tuning In the MC521 Pro Controller Using the Controller Pushbuttons NOTE: 1. To change the INDEX Hold switch while pressing to get to desired...
  • Page 9 MC521 PRO Control Box Table 1. FIS Procedure using Pushbuttons Step Description Display Index Value Status Code Set Function switch to Closed Turn power on. Unlock keypad. Restart Select door type: Slide, 01 single motor or 02 dual motor. 01 (single) 02 (dual) Select handing: 00 Right or 01 Left.
  • Page 10 MC521 PRO Control Box Table 3. Settings Index Min. Description Defaults Value Value Single Dual Open speed, increment by 1. Close speed, revolutions per second. Check speed, revolutions per second. Open check length. Close check length. Reduced open position, percent of full opening (00=full open, 99=full close). Hold open delay (0 to 25 sec.).
  • Page 11 MC521 PRO Control Box Table 4. Status Codes Status Code Description Remediation IF Necessary Normal operation—All OK Obstruction Breakout System error See attachment 7 Internal Communication Error – Type 1 See attachment 7 Motor Drive Failure Replace Controller Internal Communication Error – Type 2 See attachment 7 First installation sequence (FIS) Auto-configuration sequence...
  • Page 12: Final Tune-In Adjustments

    Threshold Sensor Installation and Operation,” and TUNE-IN Stanguard threshold sensor. 3. IF SU-100 motion sensor(s) are installed, refer to Stanley Access Technologies document No. 203957, “SU-100 Motion Sensor Installation and Operation,” and TUNE-IN SU-100 motion sensor(s). 4. IF OA-203C presence sensor(s) are installed, refer to manufacturer’s instructions and TUNE-IN OA-203C presence sensor(s).
  • Page 13: Spare Parts List

    MC521 PRO Control Box Table 6. Spare Parts List Description Part Number MC521 Pro Controller, includes 4 terminal blocks 314117 MC521 Pro Controller Manual 204066 Harness, Rocker Switch to Control Box, 98 inches 414098 Harness, Rocker Switch to Control Box, 180 inches 414099 Harness, Holding Beam to Control Box, 24 inches 414106...
  • Page 14: Attachments

    MC521 PRO Control Box Attachment 1 MC521 Pro Controls and Indicators (Sheet 1 of 2) SEE DETAIL A DETAIL A NOTE: See next page for indicators and descriptions Document # 204066 REV D2 • www.stanleyaccesstechnologies.com • 1.800.7.ACCESS...
  • Page 15 MC521 PRO Control Box Attachment 1 MC521 Pro Controls and Indicators (Sheet 2 of 2) ITEM CONTROL/INDICATOR DESCRIPTION Motor 2 Connector P402 Motor No. 2 connector. Connection point for incoming line, neutral, and common Power Connector J500 power wiring. Fuse F500 Controller fuse-- 5 Amp, 250V Motor 1 Connector P401 Motor No.
  • Page 16: Attachment 2 - Mc521 Pro System Wiring Diagram

    MC521 PRO Control Box Attachment 2 MC521 Pro System Wiring Diagram (Sheet 1 of 6) Document # 204066 REV D2 • www.stanleyaccesstechnologies.com • 1.800.7.ACCESS...
  • Page 17 MC521 PRO Control Box Attachment 2 MC521 Pro System Wiring Diagram (Sheet 2 of 6) 1.800.7.ACCESS • www.stanleyaccesstechnologies.com • Document # 204066 REV D2...
  • Page 18 MC521 PRO Control Box MC521 PRO Control Box Attachment 2 MC521 Pro System Wiring Diagram (Sheet 3 of 6) Document # 204066 REV D2 • www.stanleyaccesstechnologies.com • 1.800.7.ACCESS Document # 204066 REV D • www.stanleyaccesstechnologies.com • 1.800.7.ACCESS...
  • Page 19 MC521 PRO Control Box Attachment 2 MC521 Pro System Wiring Diagram (Sheet 4 of 6) 1.800.7.ACCESS • www.stanleyaccesstechnologies.com • Document # 204066 REV D2...
  • Page 20 MC521 PRO Control Box Attachment 2 MC521 Pro System Wiring Diagram (Sheet 5 of 6) COLOR DUAL HOLDING BEAM WIRING OUTPUT UPPER RECEIVER (-) UPPER RECEIVER OUTPUT LOWER RECEIVER (-) LOWER RECEIVER TRANSMITTER CONTROL LOWER AND UPPER NO CONNECTION NO CONNECTION (+) ALL RECEIVERS AND TRANSMITTERS (-) LOWER AND UPPER TRANSMITTERS, JUMPER TO TB6-10 JUMPER FROM TB6-9...
  • Page 21 MC521 PRO Control Box Attachment 2 MC521 Pro System Wiring Diagram (Sheet 6 of 6) COLOR DUAL HOLDING BEAM WIRING JUMPER FROM TB6-3 NO CONNECTION YL, WH OUTPUT RECEIVER, JUMPER FROM TB6-1 (-) RECEIVER TRANSMITTER CONTROL NO CONNECTION NO CONNECTION (+) RECEIVER AND TRANSMITTER (-) TRANSMITTER, JUMPER TO TB6-10 JUMPER FROM TB6-9...
  • Page 22: Attachment 3 - Mc521 Pro Terminal Block Connections Tb1-Tb7

    MC521 PRO Control Box Attachment 3 MC521 Pro Terminal Block Connections -- TB1 through TB7 (Sheet 1 of 1) Document # 204066 REV D2 • www.stanleyaccesstechnologies.com • 1.800.7.ACCESS...
  • Page 23 MC521 PRO Control Box Attachment 4 ANSI/BHMA and UL Compliance Requirements for Sliding Doors (Sheet 1 of 2) Final adjustment and proper operation of the door system must be and shall be performed in the field. NOTE : These instructions are for informational purposes and do not substitute for review against the current revision of the referenced standards.
  • Page 24 MC521 PRO Control Box Attachment 4 ANSI/BHMA and UL Compliance Requirements for Sliding Doors (Sheet 2 of 2) To ensure that a sliding door operates in accordance with UL 325 entrapment protection criteria the following must be established: • Manual opening force (sliding doors without breakout) or breakout force with power on or off must be less then 50 lbf (222.4 N).
  • Page 25: Attachment 5 - Handheld Device Troubleshooting Aid

    MC521 PRO Control Box Attachment 5 -- Handheld Device Troubleshooting Aid (Sheet 1 of 1) Terminal and Pin Description State TB1-8 Solenoid Lock Output Dark = Unlocked w/o PCB, fail secure Dark = Unlocked w/o PCB, fail safe Dark = Locked Rotary Function Switch States for TB2 Hold Closed...
  • Page 26: Attachment 6 - Handheld Device Troubleshooting Screen Descriptions

    MC521 PRO Control Box Attachment 6 Handheld Device Troubleshooting Screen Descriptions (Sheet 1 of 1) TB1-8 Swing = Bodyguard Data Line Output or Lock Output Slide = Solenoid Lock Output TB2-1 Swing/Slide = Hold Open Function Switch Input TB2-3 Swing/Slide = Automatic Function Switch Input TB2-5 Slide = Enter/One Way Switch Input TB2-7 Slide = Reduced Open Switch Input TB2-9 Slide = Reduced Open/One Way Single Pole Rotary Input...
  • Page 27: Attachment 7 - Mc521 Pro Troubleshooting Aid

    MC521 PRO Control Box Attachment 7 MC521 Pro Troubleshooting Aid (Sheet 1 of 1) Symptom Remedy Use best practices to troubleshoot using handheld device and provided wiring diagrams. Check hold beam type (index 20) Optex hold beams should Door does not close and/or be set to “Optex”...
  • Page 28: Attachment 8 - Recommended Values For Different/Weights Types Of Slide Door

    MC521 PRO Control Box Attachment 8 Recommended Values for Different/Weights Types of Slide Door Index Description Slide Doors 125 LB 350 LB 100 LB 600 LB Dura-Max Single Motor Single Motor Single Motor Double Diamond Single Slide Bi-Part - LPH Bi-part or Equiv.
  • Page 29: Attachment 9 - Fine Tuning Slide Doors

    Fine Tuning Slide Doors (Sheet 1 of 2) Tuning the Stanley Automatic Door Match your actual door to one from the list of doors described in the attachment. Start by installing these settings. Use the guide below to make adjustments to these settings.
  • Page 30 Attachment 9 Fine Tuning Slide Doors (Sheet 2 of 2) Tuning the Stanley Automatic Door (Continued). Match your actual door to one from the list of doors described in the attachment. Start by installing these settings. Use the guide below to make adjustments to these settings.

Table of Contents