7-2. Operation Data

<Cooling>
Tempeature
Model name
condition(°C)
RAS-
Indoor
Outdoor
27/19
35/-
10SKV-E
10SKV-A
<Heating>
Tempeature
Model name
condition(°C)
RAS-
Indoor
Outdoor
20/-
7/6
10SKV-E
10SKV-A
NOTES :
1. Measure surface temperature of heat exchanger pipe around center of heat exchanger path U bent.
(Thermistor themometer)
2. Connecting piping condition : 5 m
Heat exchanger
Standard
pipe temp.
pressure
P (MPa)
T1 (°C)
0.9 to 1.1
9 to 11
Heat exchanger
Standard
pipe temp.
pressure
P (MPa)
T1 (°C)
2.4 to 2.6
43 to 45
– 21 –
FILE NO. SVM-07008
Indoor
fan mode
T2 (°C)
47 to 49
High
Indoor
fan mode
T2 (°C)
0 to 3
High
Outdoor
Compressor
fan mode
revolution
(rps)
High
54
Outdoor
Compressor
fan mode
revolution
(rps)
High
68