11.14 TECHNICAL NOTES
11.14.1
Hardware Mapping
The subrack ID as setup on the HMX128 card defines the ID for all functions of the
HMX32128 subrack, i.e. when defining pan/tilt control or text attributes the subrack ID
fields will be as per the HMX128 setting.
As the MAXPRO-Net HD series incorporates all of is functionality via one subrack ID it
was necessary to "map" this to "slot" numbers which may then be entered via SETMAX,
the MAXPRO-Net
The hardware mappings are as follows: -
a. Video Fail/Level Detection
b. Pan/Tilt Control Ports
c. Text
Rev. C
®
configuration editor.
Physical Input
1 - 32
33 – 64
65 – 96
97 - 128
Physical Outputs on
Control Card
1
2
3
4
5
6
7
8
Text
Output Card 1
Output Card 2
Output Card 3
Output Card 4
Slot
(FSL field in SETMAX)
11
12
13
14
Slot
(CSL field in SETMAX)
1
2
3
4
5
6
7
8
Slot
(TSL field in SETMAX)
1 – 8
9 – 16
17 – 24
25 – 32
11-9
HMXMU001018