3.4 Serial Interfaces
Number
Controller
Bit rate
Physical Interface
Connector
3.5 CAN Interfaces
Number
CAN controller
CAN protocol
Physical interface
Transmission rate
Electrical isolation
Bus termination
Connector
EPPC-405-UC
3 serial interfaces:
COM1:
RS-232 interface
COM2:
RS-232 interface
COM3:
RS-485 interface
COM1:
integrated in PowerPC 405EP
COM2+3:
external Duart
COM1:
max. 115.2 Kbit/s
COM1:
max. 120 Kbit/s
COM3:
max. 1.5 Mbit/s
COM1:
RS-232C
COM2:
RS-232C
COM3:
RS-485
COM1:
8-pole RJ45 socket
COM2:
8-pole RJ45 socket
COM3:
8-pole RJ45 socket and 4-pole MINI-COMBICON
connector with double level header
Table 4: Data of the serial interface
2
SJA1000
acc. to ISO 11898-1 (CAN 2.0 A/B)
CAN interface according to ISO 11898-2
10 Kbit/s ... 1 Mbit/s
via magnetic data couplers IL712
has to be set externally if required
MINI-COMBICON with double level header (2 x 5-pole)
(type: MCDV 1,5/5-G1-3,81)
Table 5: CAN interface
Hardware Manual • Doc. No.: I.2005.21 / Rev. 1.2
Technical Data
Page 15 of 44