Download Print this page

Advertisement

Quick Links

SCENAR 1-NT
The first steps
RITM OKB ZAO

Advertisement

loading
Need help?

Need help?

Do you have a question about the SCENAR 1-NT and is the answer not in the manual?

Questions and answers

Summary of Contents for RITM OKB ZAO SCENAR 1-NT

  • Page 1 SCENAR 1-NT The first steps RITM OKB ZAO...
  • Page 2 Basis states Amplitude setting / "O" state button 2 sec without pressing buttons “+”, “-" 2 sec without pressing MENU button 2 sec without pressing DOSE...
  • Page 3 The “O” state screen...
  • Page 4 Sounds while amplitude setting Each step of amplitude setting is indexed with click; When min/max of the amplitude is reached long signal sounds.
  • Page 5 Sounds during work (dosing is off) Every 30 sec (without button pressing) short signal sounds. 30 sec 30 sec 30 sec...
  • Page 6: The Menu Structure

    The menu structure...
  • Page 7 “Dose mode” АМ Dose...
  • Page 8 “Dose mode” Working in dose mode (screen information and sounds) will be observed later!
  • Page 9 “Amplitude modulation mode” АМ FМ Dose 5:1 ... 2:1...
  • Page 10 Sounds in “Amplitude modulation mode”  No  1:1  2:1  3:1  4:1  5:1  Bee...
  • Page 11 “Frequency modulation mode” АМ FМ Sw 4... Sw1...
  • Page 12 “Frequency modulation mode”...
  • Page 13 Sounds in “Frequency modulation mode”  No  On  Sw1  Sw2  Sw3  Sw4...
  • Page 14 “Damping mode” FМ Sc4 ... Sc2...
  • Page 15 Sounds in “Damping mode”  No  Sc1  Sc2  Sc3  Sc4  Var...
  • Page 16 “Frequency mode” 15 ... 350...
  • Page 17 Sounds in “Frequency mode”  15,3Hz  29,7Hz  59,3Hz  90,3Hz  121 Hz  180 Hz  351 Hz...
  • Page 18 “Intensity mode”...
  • Page 19 “Gap mode” Dose 10 ... 80...
  • Page 20 Practice  Set max frequency  Switch on the combination “FМ-Var”  Switch on damping “Sc4”  Switch Dose mode “Dose=1”  Switch off the modulation  Set intensity 2, 3,...,8  While increasing Gap, watch the intensity  Switch the device off and switch it on again...
  • Page 21 “Dose mode 1-2” No contact (nobody) Contact...
  • Page 22 “Dose mode 1-2” 1 sec...
  • Page 23 “Dose mode 1-2” The dose, the zero...
  • Page 24 “Dose mode 3” initial reactions initial coefficients of form...
  • Page 25 “Dose mode 4”...
  • Page 26 “Dose mode 5”...
  • Page 27 Practice  Switch the device on, set the comfortable influence level.  Switch Dose mode “Dose=1”.  Set the device at the same skin area several times with the same pressing. Watch the initial reaction.  Set the device at that skin area with different pressing.
  • Page 28 Practice  Set the device at different skin areas, watch the initial reaction.  Select the area with the max initial reaction.  Set the device at this area, wait for “dose” and “zero”.
  • Page 29: Service Menu

    Service menu...
  • Page 30 Service menu and ‘+’ To enter the Service menu, press the buttons simultaneously, and a rising beep will sound.
  • Page 31 Service menu When no buttons are pressed within 3 seconds, the device switches to the previous state, and the value of the highlighted parameter (and this value solely) is saved in the constant memory of the device. If the value has been changed, then a descending beep will sound.
  • Page 32 “Auto Off (AOff)” When the AOff is set to Off, the automatic turn- off is disabled. This may cause faster battery exhaustion when you leave the device switched on for a long time.
  • Page 33 “Auto Off (AOff)” The differences of the automatic turn-off are given in the table. Automatic turn-off time when no buttons pressed. AOff Nobody Contact Timer reset never (only when buttons never never pressed) never 5 min Every time the electrode contacts 30 sec / taken up from the skin 10 min...
  • Page 34 “Light (Lght)” The Lght menu item is the time of screen back- lighting for the following events: – pressing any button, – reaching the Dose or Zero, – expiration of the first second of measuring in the Dosing state – expiration of every 30 seconds.
  • Page 35 “Save Screen (Save Scr)” The Save Scr menu item allows to save the current orientation of the image on the screen as default.
  • Page 36 “Sound (Snd)” The Snd menu item is for volume control. When Snd 0 is set, all sounds except for clicks while controlling the energy strength will be disabled, and in the Basic state a corresponding indication will be displayed in the top line of the screen. Snd 1 is for minimum sound volume, Snd 2 –...
  • Page 37 ‘Write’ The Write menu item allows to save up to 5 sets of Stimulus Attributes (Dose, AM, FM, Dmp, F, Int, and Gap). To save the sets of parameters in one of 5 cells, select the cell number and wait until the device exits the Service menu.
  • Page 38 ‘Read’ The Read menu item allows to read the earlier saved sets of parameters of the basic modes of stimulation from the constant memory. Select the number (1…5) of the cell that contains your presettings saved earlier and wait until the device exits the Service menu.
  • Page 39: Other Settings

    Other settings The Cont menu item allows to control the image contrast. The Lng menu item allows to select a language (2 languages are available – Russian and English).
  • Page 40 Practice  Select the service menu, set ‘AOff Off’ and pass to the next item. Listen to the sound while returning to main menu.  Place the device on the skin and take out several times, watch the timer and skin contact indicator. ...
  • Page 41 Practice  Take off the device and watch the timer for more than 30 sec.  Press button.  Switch the device off and switch it on again.  Select the service menu and watch ‘AOff’ state.  Set ‘AOff 5m’ and pass to the next item. ...
  • Page 42 Practice  Set “Snd 0” item in the service menu.  Listen to the sound while returning to main menu.  Look the upper right corner of the screen.  Decrease ‘Energy’ to 1 and listen to the sound.  Set “Snd 2” item in the service menu. ...
  • Page 43 The certificates...
  • Page 44 Russia...
  • Page 45 Europe...
  • Page 47: Other Countries

    Other countries...