    IMPORTANT – READ CAREFULLY NOTE – To prevent potential injury and to avoid unnecessary service calls, read this manual carefully and completely. SAVE THIS INSTRUCTION MANUAL Use of appointed replacement parts voids warranty. ATTENTION INSTALLER – THIS MANUAL CONTAINS IMPORTANT INFORMATION ABOUT THE INSTALLATION, OPERATION, AND SAFE USE OF THIS PUMP THAT MUST BE FURNISHED TO THE END USER OF THIS PRODUCT.
  • Page 3 Also, contact a licensed electrician for information on local electrical codes for bonding requirements. Use a solid copper conductor, size 8 or larger. Run a continuous wire from external bonding lug to reinforcing rod or mesh. Connect a No. 8 AWG (8.4 mm ) solid copper bonding wire to the pressure wire connector provided on the motor housing and to all metal parts of swimming pool, spa, or hot tub, and to all electrical equipment, metal piping (except gas piping), and conduit within 5 ft.
  • Page 4: Installation Instructions

    Failure to follow safety and operation instructions could result in violent separation of pump components. Strainer cover must be properly secured to pump housing with strainer cover lock ring. Before servicing pool and spa circulation system, all system and pump controls must be in off position and filter manual air relief valve must be in open position. Do not operate pool and spa circulation system if a system component is not assembled properly, damaged, or missing.
  • Page 5 NOTE - It is recommended that a minimum length of piping, equivalent to 10 pipe diameters, be used between the pump suction inlet and any plumbing fittings. WARNING – Hazardous Pressure. Pumps, filters, and other equipment/ components of a swimming pool filtration system operate under pressure. Incorrectly installed and/or improperly tested filtration equipment and/or components may fail resulting in injury and/or property damage.
  • Page 6: Start-Up And Operation

    Voltage Voltage at motor MUST NOT be more than 10% above or below motor name plate rated voltage, or motor may overheat, causing overload tripping and reduced component life. If voltage is less than 90% or more than 110% of rated voltage when motor is running at full load, consult Power Company.
  • Page 7: Maintenance

    may damage pump and voids warranty. ATTENTION – Before removing strainer cover: 1. STOP PUMP before proceeding. 2. CLOSE VALVES in suction and outlet pipes. 3. RELEASE ALL PRESSURE from pump and piping system using filter manual air relief valve. See filter owner’s manual for more detail.
  • Page 8: Shaft Seal Change Instructions

    E. Exercise extreme care in handling both the rotating and the stationary sections of the two-part replacement seal. Foreign matter or improper handling will easily scratch the graphite and ceramic sealing surfaces. TECHNICAL DATA model Voltage Hertz Amps Flow Rate J07501 73GPM J11501 115/230 13/6.5 84GPM J15001 115/230 15/7.5...
  • Page 9 Art.No JR07501001 O-Ring JR07501002 Basket JR07501003 Strainer JR07501004 Drain plug JR07501005 O-Ring JR07501006 Diversion sets JR07501007 Impeller of item# J07501/J07502 JR07501008 Impeller of item#J11501/J11502 JR11501008 Impeller of item#J15001/J15002 JR15001008 O-Ring JR07501009 Pump housing JR07501010 Screw JR07501011 Motor of item#J07501 JR000751...
  • Page 10 Parts for pump models: J05503/J07503/J11503/J07504/J11504 Key NO Description Art.No JR07501001 O-Ring JR07501002 Basket JR07501003 Clamp JR05502004 Strainer JR05502005 Drain plug JR07501005 O-Ring JR05502007 Screw JR05502008 Pump cover JR05502009 O-Ring JR05502010 Impeller of item#J05503 JR05502011 Impeller of item#J07503/J07504 JR07502011 Impeller of item#J11503/ J11504 JR11502011 Pump housing JR05502012...
  • Page 11 Parts for pump models: J11801/J12601 Key NO Description Art.No Pump housing JR01801001 Impeller of item#J01801 JR01801002 Impeller of item#J02601 JR02601002 O-Ring JR01801003 Pump cover JR01801004 Motor of item#J11801 JR000181 Motor of item#J12601 JR000261 Screw JR01801006 Seal assembly JR01801005...
  • Page 12 Parts for pump models: J11802/J12602 Key NO Description Art.No JR01802001 O-Ring JR01802002 Basket JR01802003 Strainer JR01802004 Drain plug JR05502005 Screw JR01802006 O-Ring JR01802007 Diversion sets JR01802008 Impeller of item#J11802 JR11801002 Impeller of item#J12602 JR12601002 O-Ring JR01802010 Pump housing JR01802011 Motor of item#J11802 JR000181 Motor of item#J12602 JR000261...
  • Page 13: Troubleshooting

    Trouble Shooting ISSUE POSSIBLE SOLUTION Improper or loose wiring connections; open switches or relays; tripped circuit breakers, MOTOR WILL NOT GFCI’s, or blown fuses. START Manually check rotation of motor shaft for free movement and lack of obstruction. If you have a timer, be certain it is working properly. Bypass it if necessary. Undersized wiring;...