Description
Hands-free Mini Wi-Fi door entry monitor for Simplebus2 system which, when used in conjunction with the Comelit app (available
to download free of charge from the Google and Apple stores) and/or the Alexa/Ecoshow/Google Assistant voice assistants,
can be used to answer calls directly from your smartphone/tablet/voice assistants, both locally and remotely. It can be used
to enable the "Face recognition" function directly from the app, to automatically - once a person has been recognised - send a
lock-release command (enabled by default), trigger an actuator to control a light or additional opening and receive notification
when a known individual makes a call.
It allows operation of the new Comelit WiFree series of Wi-Fi home automation devices. It is also possible to control devices
with different protocols, thereby integrating any third-party home automation system for controlling gates or outdoor lights, or
for activating scenarios, etc.
Replacing an old door entry monitor to benefit from all the advantages offered by Wi-Fi technology is no longer problematic: Mini
Wi-Fi is actually compatible with all types of Comelit Simplebus2 colour video entry system and does not require any additional
masonry work.
Art. 6741W is supplied with a mounting backplate and riser distribution terminal art. 1214/2C.
Art. 6741W/BM is equipped with a magnetic induction audio amplification system, and does not come with backplate art.
6710, which is available to purchase separately.
1
2
4
5
6
1. Brightness control
f To increase the value, turn clockwise
2. Loudspeaker volume control
f To increase the value, turn clockwise
3. Call volume adjustment (high - medium - low)
4. 4.3'' / 16:9 LCD screen
5. Speaker and audio activation button
6. Touch-sensitive buttons
7. S1
DIP-switches for user code programming (see
8. S2
DIP-switches for programming buttons and functions
DIP 1-2-3-4 for key function programming
DIP 5-6 for access to programming
DIP 7 for power supply voltage management (see
S2 DIP 7 must always be set to ON, even in systems with 4888C and 4888CU (as in the factory settings).
DIP 8 (not used)
9.10. Factory setting - DO NOT CHANGE!
11. CV 5 Jumper for video closure. In systems with more than one door entry monitor connected in cascade, only the door entry
monitor furthest away must have CV5 closed.
12. Pin for securing terminal block
13. S3 DIP-switch:
DIP 1 to set the correct operating mode (see
DIP 2 (not used)
Terminal block for system connection:
LL BUS line connection terminals
CFP1 CFP2 Floor door call input
7
8
9
3
10
11
12
13
"Addressing table" on page
"Power Management" on page
"Building mode, Kit mode" on page
6)
8). Default = ON
7)
< BACK
3
Need help?
Do you have a question about the 6741W and is the answer not in the manual?
Questions and answers