Pergola may be required to eliminate the risk. For existing installations, before making any changes to the con guration, the components attached to, or the install location of Pergola product, always consult with a Haworth dealer to review the structural stability of the intended changes. COMPLIANCE Pergola is considered a free-standing, nonstructural, architectural component subject to applicable building codes and authorities having jurisdiction.
Page 4
Table of Contents SECTION 1. Safety, Tools, and Preparation SECTION 2. Main Frame SECTION 3. In ll Frames SECTION 4. Tiles/Electric SECTION 5. In ll and Caps SECTION 6. Ceilings SECTION 7. Accessories SECTION 8. Power...
PERGOLA® Section 1 - Safety Safety Precautions PERSONAL PROTECTIVE EQUIPMENT Steel-toed shoes, cut resistant gloves, and safety glasses are recommended to be worn during the installation of this product. In addition, when handling glass, cut resistant arm sleeves are recommended. RISK OF INJURY DO NOT hang from, stand on, or otherwise use Pergola structures or components to support a person’s body weight in any way.
Hardware Guide WARNING: ALWAYS USE THE PROPER BOLTS THAT ARE SENT TO Scale 1 : 1 ASSEMBLE THE PRODUCT. (S260) 9/16” Wrench Size Tensile Bolt Grade No. Range Strength Markings 1/4 thru 1-1/2 3/8" x 1-3/8" Hex Head Bolt - Grade 8 1/4 thru 3/4 (S259) 9/16”...
PERGOLA® Section 1 - Prep Pre-Installation Product Staging Prior to beginning the installation, it is recommended to sort and stage the product by order of install to experience a faster, more orderly installation. Review the product labels on each box to determine the install group for that product and stage accordingly.
If anchorage is required, start by locating post positions on oor and install brackets (F) WARNING: Appropriate fasteners must be used to attach bracket(s) to oor. Fasteners are not provided by Haworth. Consult with the customer appointed engineer for fastener recommendations.
Page 10
Main Frame 2-WAY POST 3-WAY POST 4-WAY POST POST, UNDERBEAM TOP FRAME RAIL (S260) Joint Reinforement Bracket 3/8" x 1-3/8" Hex Head Bolt - Grade 8 S256 (S259) 3/8" x 2" Hex Head Bolt - Grade 8 S226 (S258) S260 NOTE: As required for high structural 5/16 x 7/8"...
Page 11
Main Frame - Reinforced Joint Application S226 (S258) S258 S257 5/16 x 7/8" Hex Head Bolt (S257) (S226) 5/16 x 1-1/4" Hex Head Bolt 1/4-20 x 1" Hex Head Bolt Main Frame - Reinforced Joint Application (S258) 5/16 x 7/8" Hex Head Bolt (S257) S258 S257...
Page 12
Main Frame Assembly (S256) 1/4-20 x 2-1/4" Hex Head Bolt (S259) 3/8" x 2" Hex Head Bolt (S260) O Mod Rail 3/8" x 1-3/8" Hex Head Bolt Standard-Rail Reinforced Joint Standard Joint S260 S260 S256 NOTE: Bolt (S256) is not required. S259 S259 S256...
Page 13
Main Frame Assembly S256 Reinforced Joint Standard Joint NOTE: Bolt (S256) is not required. S259 S259 S256 S260 S260 NOTE: Optional Brace to assist when assembling frame. Supplied by others. (S260) 3/8" x 1-3/8" Hex Head Bolt (S259) (S256) 1/4-20 x 2-1/4" Hex Head Bolt 3/8"...
Page 14
Main Frame Assembly - Round S258 S257 S260 (S258) 5/16 x 7/8" Hex Head Bolt (S257) 5/16 x 1-1/4" Hex Head Bolt (S260) 3/8" x 1-3/8" Hex Head Bolt (S259) 3/8" x 2" Hex Head Bolt CUSTOMER SERVICE PHONE: 1-800-426-8562...
Page 15
Main Frame Assembly - Round (S259) 3/8" x 2" Hex Head Bolt (S260) 3/8" x 1-3/8" Hex Head Bolt CUSTOMER SERVICE PHONE: 1-800-426-8562...
Page 16
Floor Anchor WITHOUT ANCHOR 1/2” Minimum WITH ANCHOR NOTE: Start leveling from high spot of oor. Begin levelers at the minimum and adjust as needed. 1-1/8” Minimum CUSTOMER SERVICE PHONE: 1-800-426-8562...
Page 18
Post, Underbeam EOR +1” X + 1” = Y X + 1” = Y OPEN SIDE WALL SIDE 2.10 CUSTOMER SERVICE PHONE: 1-800-426-8562...
Page 19
Post, Underbeam EOR (S100) #12 x 1/2" Screw NOTE: Install S100 screws loosely. Install all components to complete wall before next step (Refer to Section 3) 2.11 CUSTOMER SERVICE PHONE: 1-800-426-8562...
Page 20
Post, Underbeam EOR Install carpet gripper and secure post (S100) #12 x 1/2" Screw S100 0.0” SMOOTH CARPET 2.12 CUSTOMER SERVICE PHONE: 1-800-426-8562...
PERGOLA® Section 3 - Insert Frames Components Bottom Rail - Standard Centerbeam Tile Rail Horizontal Tile-Tile Rail Horizontal Turnbuckle S265 Horizontal Tile-Insert Rail Vertical/Horizontal Tile-Frame Rail Vertical Tile-Tile Rail (S265) #10 x 5/8” Self Drilling Pan Head Screw CUSTOMER SERVICE PHONE: 1-800-426-8562...
Page 22
Wall Assemblies GLASS VERTICAL TILE OPEN-TO-HORIZONTAL TILE OPEN TILE TILE GLASS TILE CUSTOMER SERVICE PHONE: 1-800-426-8562...
Page 23
Wall Assemblies GLASS-TO-HORIZONTAL TILE HORIZONTAL TILES OPEN-TO-TILE-TO-OPEN TILE OPEN GLASS TILE TILE TILE TILE OPEN CUSTOMER SERVICE PHONE: 1-800-426-8562...
Page 24
Bottom Rail S100 NOTE: Leveler included with 8, 10, and 12 foot lengths only. S100 (S100) #12-24 x 1/2" Screw CUSTOMER SERVICE PHONE: 1-800-426-8562...
Page 25
Horizontal Tile-to-Tile Rail Standing Seated S100 S100 (S100) #12-24 x 1/2" Screw CUSTOMER SERVICE PHONE: 1-800-426-8562...
Page 26
Horizontal Tile-Insert Rail TILE S100 S100 Standing Seated Tile Side NOTE: Chamfered side always towards the tile side of the rail. NOTE: Bottom rail in not installed in Tile Side S100 this setup. (S100) NOTE: Orient rail to align with tile. #12-24 x 1/2"...
Page 27
Horizontal Tile-Insert Rail-Support Bracket S105 (S105) #8 x 3/4" Self-Drilling Screw CUSTOMER SERVICE PHONE: 1-800-426-8562...
Page 31
Centerbeam Tile Rail - Electrical Tile Width 1” Tile Width Half Tile Width Minus 36” 18” 1” 17” 48” 24” 1” 23” 72” 36” 1” 35” 96” 48” 1” 47” 120” 60” 1” 59” NOTE: Make sure the Rail is properly oriented for power installation.
Page 32
Horizontal Tile-Insert Rail-Turnbuckle S265 NOTE: Turnbuckles are only required on 12’ wide suspended rails with split tiles. S265 (S265) #10 x 5/8” Self Drilling Pan Head Screw 3.12 CUSTOMER SERVICE PHONE: 1-800-426-8562...
PERGOLA® Section 4 - Tiles/Backer Components Tile Plywood Backer & Brackets Hanger Brackets Electrical Support Beam S265 (S265) #10 x 5/8” Self Drilling Pan Head Screw CUSTOMER SERVICE PHONE: 1-800-426-8562...
Page 34
Plywood Backer - For Electrical Determine location of plywood backer Plywood Backers with Electrical CONDUIT ON Height Subtract Location A” -12” =X” NOTE: Center plywood backer cutout as shown. NOTE: Power installation, refer to Section 8. 12” A - 12”=X” X”...
Page 35
Plywood Backer - Non-Electrical Determine random location of plywood backer NOTE: For non power tiles locate plywood backer as needed. X2” X2” CUSTOMER SERVICE PHONE: 1-800-426-8562...
Page 36
Plywood Backer Mark location of plywood backer with tape Install rst bracket aligning with tape NOTE: Center brackets with holes in plywood backer (2 per side). NOTE: If obstacles are present, relocate brackets to other locations from top or bottom (as shown). NOTE: Maximum distance between brackets is recommended.
Plywood Backer Install 4 brackets per plywood backer S265 BACK TO BACK (S265) #10 x 5/8” Self Drilling Pan Head Screw Attached plywood backer to brackets (S104) #10 x 1-1/2" Tek Screw Self Drilling S104 CUSTOMER SERVICE PHONE: 1-800-426-8562...
Electrical Support Beam Install electrical support beam APPLY PRESSURE TIGHTEN SCREW NOTE: Install rail close to power adding strength and stability to structure. Electrical Installation Receptacle Switch Refer to Section 8 when installing electrical CUSTOMER SERVICE PHONE: 1-800-426-8562...
Page 39
Tile Installation Install power tile rst than install non power tiles second 1/8” (2.5mm) Reference 1/8” (2.5mm) Reference 1/8” (2.5mm)Reference NOTE: Use cardboard as a spacer reference for the gap between tile and rail. NOTE: Install all power tiles rst. NOTE: Check to make sure tile connector is attached properly.
Page 42
Glass Wall Installation Install vertical channel caps Insert glazing beads NOTE: Remove 3” of material from top of each end of the glazing bead as shown. 3” CUSTOMER SERVICE PHONE: 1-800-426-8562...
Page 43
Install glass panes CUSTOMER SERVICE PHONE: 1-800-426-8562...
Page 44
Glass Wall Glazing Connector Installation Connector, In-line Connector, In-line 10mm Glazing Connector, In-Line 10mm NOTE: Prep edge of glass with a 50/50 Isopropyl Alcohol and distilled water solution. A damp lint free cloth is pulled in one motion from top to bottom of glass edge.
Curtain Installation Set curtain track cable to pull from left or right side RIGHT SIDE NOTE: Only connect one end of cable. Connect either left side or right side. NOT BOTH SIDES. LEFT SIDE 1) Remove screw 2) Remove end cap 3) Insert screw into cable 4) Install end cap and secure with screw 1) Remove Screw...
PERGOLA® Section 6 - Ceilings Ceiling Slat Rail (Square Room) Ceiling Slat Rail (Radial Room) Intersection Covers Top Rail Cover 1/2 Round 2 Way Light Trough Cover 3 Way/Full Round 4 Way Top Rail Cover (Radial) CUSTOMER SERVICE PHONE: 1-800-426-8562...
Page 53
Template - For Square Room & Half Round Create a cardboard and/or wood template SQUARE HALF ROUND 5-3/8” (Rest of Ceiling Slats) Minimum 18” with ceiling slats 2-3/4” (First Ceiling Slat) FIRST CEILING SLAT REST OF CEILING SLATS 2-3/4” 5-3/8” CUSTOMER SERVICE PHONE: 1-800-426-8562...
Page 54
Ceiling Slat Rail Installation - Square Room Install Ceiling Slats 2-3/4” 5-3/8” FOR REMOVING SLAT - USE A PUTTY KNIFE 1/2” 2-3/4” (69.5mm) 5-3/8” CUSTOMER SERVICE PHONE: 1-800-426-8562...
Page 55
Template - For Full Round Create a cardboard and/or wood template FULL ROUND 5-3/8” (Rest of Ceiling Slats) 4-3/4” (First Ceiling Slat) Minimum 18” with ceiling slats 5-3/8” 4-3/4” CUSTOMER SERVICE PHONE: 1-800-426-8562...
Page 56
Ceiling Slat Rail Installation - Full Round Room Install Ceiling Slats (S105) #8 x 3/4" Self-Drilling Screw 1/2” CUSTOMER SERVICE PHONE: 1-800-426-8562...
Page 57
Top Rail Cover Support Brackets Install radial top cover support bracket (5 per rail section) Repeat for each radial section (S105) #8 x 3/4" Self-Drilling Screw S105 CUSTOMER SERVICE PHONE: 1-800-426-8562...
Page 58
Top Rail Cover Installation For Square Room Place 2 way, 3 way, and 4 way covers on top of posts Install straight covers snapping into top rails Top Rail Cover Installation For Half & Round Room Place 3 way covers on posts Remove backing from velcro and install covers HALF ROUND FULL ROUND...
Page 59
Light Trough Cover Installation Mark location as shown Cut notch in top rail cover CUT TO HERE 2-1/2” CUSTOMER SERVICE PHONE: 1-800-426-8562...
PERGOLA® Section 7 - Accessories Coat Hanger Tray Ledge Spanning Top (Full) TV Mount (Workware) Spanning Top (Half ) CUSTOMER SERVICE PHONE: 1-800-426-8562...
Page 61
Tray or Ledge Installation Horizontal Tile Rail - Tile Horizontal Tile-Insert Rail TRAY LEDGE COAT HANGER PULL CORNER TO REMOVE CUSTOMER SERVICE PHONE: 1-800-426-8562...
Coat Hanger Installation Install hanger to top rail NOTE: Make sure the coat hanger is fully engaged. SIDE VIEW CUSTOMER SERVICE PHONE: 1-800-426-8562...
Page 63
Spanning Top Installation Install plates to underside of top (S-1) #10 x 1" Pan Head Screw FULL HALF CUSTOMER SERVICE PHONE: 1-800-426-8562...
Page 64
Spanning Top Installation (S105) Install anti-twist brackets and foam tape #8 x 3/4" Self-Drilling Screw S105 144” 72” NOTE: 3rd bracket is for split tops only. Make sure the square end of the bracket is centered supporting both tops. NOTE: The foam tape is applied to the opposite side the worksurface overhangs.
Page 65
Shelf Top Installation Install shelf top to horizontal tile rail FULL NOTE: Careful not to scratch top of rail in case of future reloacation. (S275) #10-32 x 2-1/2" Pan Head Screw HALF S275 Install brackets (S-1) #10 x 1" Pan Head Screw S105 S105 CUSTOMER SERVICE PHONE: 1-800-426-8562...
Page 66
Shelf Top Installation Install covers (S276) #6-32 x 3/8" Flat Head Screw S276 CUSTOMER SERVICE PHONE: 1-800-426-8562...
Worksurface Installation Use template to locate and predrill holes 16” Maximum 24” Maximum Bracket Template 1-7/16” (1.4375”) Back Edge of Worksurface 9/16” (.5625”) 1/8” Drill 3/4” Bottom of Worksurface CUSTOMER SERVICE PHONE: 1-800-426-8562...
Page 68
Worksurface Installation Before installing brackets determine if the tile is above or below the worksurface TILE - TILE RAIL TILE (S-3) #10 x 5/8" Pan Head Screw TILE - INSERT RAIL TILE (S-3) #10 x 5/8" Pan Head Screw CUSTOMER SERVICE PHONE: 1-800-426-8562...
Page 69
Worksurface Installation Install worksurface NOTE: The worksurfaces must be supported on back edge by mounting to pergola and on the front edge by worksurface legs. 7.10 CUSTOMER SERVICE PHONE: 1-800-426-8562...
Page 71
TV Mount (Workware) Install TV mount level (S280) #10-12 x 1-3/8" Pan Head Screw S280 7.12 CUSTOMER SERVICE PHONE: 1-800-426-8562...
Page 72
TV Mount (Workware) Install brackets to TV NOTE: A variety of screw sizes and spacers are provided to accommodate a wide range of TV’s. NOTE: Install cables and plugs before proceeding to the next step. NOTE: Due to various setups cables are supplied by the customer.
HAZARD to service personnel and will cause RISK OF FIRE due to excessive each branch circuit. The person or group installing circulating currents. Haworth products is responsible for complying with WARNING: Power to all branch circuits MUST REMAIN DISCONNECTED during all applicable building and electrical code installation or removal of electrical components and raceway covers to avoid requirements.
Page 74
Tech Tower Installation Ledge Installation (partial Height Tech Tower) Remove cover Hook over top rail OPTIONAL RAILS Horizontal Tile Rail - Tile Horizontal Tile-Insert Rail Revision: 1.0 Part #: PT15-7100 CUSTOMER SERVICE PHONE: 1-800-426-8562...
Page 75
install L-bracket (S-1) #10 x 1" Pan Head Screw install ledge (S155) #10-24 Hex Nut S155 Revision: 1.0 Part #: PT15-7100 CUSTOMER SERVICE PHONE: 1-800-426-8562...
Page 76
Full Height Tech Tower Hook over top rail and secure to bottom rail Revision: 1.0 Part #: PT15-7100 CUSTOMER SERVICE PHONE: 1-800-426-8562...
Page 77
Only when installing second jumper - Step 7 Remove PDA Install jumper Reinstall PDA Remove connector Reinstall connector and install cover Revision: 1.0 Part #: PT15-7100 CUSTOMER SERVICE PHONE: 1-800-426-8562...
Page 78
Monitor Mount Installation Attach mounting brackets to tech tower Remove cover Revision: 1.0 Part #: PT15-7100 CUSTOMER SERVICE PHONE: 1-800-426-8562...
Page 79
Monitor Mount Installation Adjust thumb screws NOTE: Adjust thumb screws until they touch the tile or glass. Attach backing plate to monitor NOTE: Maximum load: 75 Kg. (165 lbs) NOTE: Screws provided may not cover all conditions. Revision: 1.0 Part #: PT15-7100 CUSTOMER SERVICE PHONE: 1-800-426-8562...
Page 80
Install cover Hang monitor onto brackets and secure with anti-uplift screws NOTE: make sure all 4 hooks are engaged. Revision: 1.0 Part #: PT15-7100 CUSTOMER SERVICE PHONE: 1-800-426-8562...
Page 81
Top Feed Installation Attach inner cover to bracket Attach mounting brackets to top rail NOTE: Bottom slots for option one and upper slots for option 2. 1/8" Drill Option 2 - Use Top Slots Option 1 - Use Bottom Slots Inner Cover Inner...
Page 82
Plumb cover (M) and locate and cut a hole in ceiling tile Attach junction box and install cover Install ceiling bezel (S144) #8-32 x 1/4" Pan Head Screw S144 S145 S135 (S145) (S135) #10-32 x 1/2" Screw #10 Hex Nut Revision: 1.0 8.10 Part #: PT15-7100...
Page 83
Install electrical box cover Tie top feed to building Revision: 1.0 8.11 Part #: PT15-7100 CUSTOMER SERVICE PHONE: 1-800-426-8562...
PDA Installation SNAP! APPLY PRESSURE TIGHTEN SCREW NOTE: Listen for a “SNAP” sound. Cable Support Installation Revision: 1.0 8.12 Part #: PT15-7100 CUSTOMER SERVICE PHONE: 1-800-426-8562...
Page 85
Ceiling Light Trough Ceiling, Light Trough ±1/8” Revision: 1.0 8.13 Part #: PT15-7100 CUSTOMER SERVICE PHONE: 1-800-426-8562...
Page 86
Ceiling Light Trough - Round ±1/8” Revision: 1.0 8.14 Part #: PT15-7100 CUSTOMER SERVICE PHONE: 1-800-426-8562...
Page 87
Optional - Receptacle Adjustments MOUNT ON RIGHT SIDE MOUNT ON LEFT SIDE Receptacle and Switch Installation Remove face plate Revision: 1.0 8.15 Part #: PT15-7100 CUSTOMER SERVICE PHONE: 1-800-426-8562...
Page 88
Install receptacle APPLY PRESSURE OPTIONAL RAILS Vertical/Horizontal Tile-Frame Rail TIGHTEN SCREW APPLY PRESSURE Vertical Tile-Tile Rail Centerbeam Tile Rail TIGHTEN SCREW Power Installation with Plywood Backer Revision: 1.0 8.16 Part #: PT15-7100 CUSTOMER SERVICE PHONE: 1-800-426-8562...
Page 89
Attach connector to PDA Revision: 1.0 8.17 Part #: PT15-7100 CUSTOMER SERVICE PHONE: 1-800-426-8562...
Page 90
Adjust tile support as needed Install tile NOTE: Refer to Section 4 when installing Tiles. NOTE: Adjust bracket until it touches tile. Attach face plate by snapping on Revision: 1.0 8.18 Part #: PT15-7100 CUSTOMER SERVICE PHONE: 1-800-426-8562...
Page 91
Low Voltage Kit Installation Secure junction box Insert junction box Install data plate Install face plate Revision: 1.0 8.19 Part #: PT15-7100 CUSTOMER SERVICE PHONE: 1-800-426-8562...
Page 92
Wiring Diagram - Four-Circuit, 3+1 Three 208Y/120V Phase Circuit Panel 4 CIRCUIT WIRE COLOR PHASE PHASE PHASE = GREY (10GA) = GREY RED (10GA) Circuit L1- Black/Hot = GREEN YELLOW (12GA) Circuit L2- Red/Hot BARE COPPER (12GA) Circuit L3- Blue/Hot = BLACK (12GA) Circuit L4- Violet/Hot = RED (12GA)
Page 93
Electrical Routing Options Vertical Tiles Horizontal Tiles Revision: 1.0 8.21 Part #: PT15-7100 CUSTOMER SERVICE PHONE: 1-800-426-8562...
Need help?
Do you have a question about the Pergola PT15-7100 and is the answer not in the manual?
Questions and answers