Advertisement

2500446
Please read all instructions carefully before use and
retain for future reference.
Disconnect appliance from mains before cleaning,
maintenance or after a thermal cut out event.
Do not cover.
CAUTION Do not immerse in water.
Do not use outdoors.
A5P | 01
Caution Risk of fire R290
Please read all instructions carefully before use and
retain for future reference.
INTENDED USE.
This Dehumidifier is for indoor domestic use only. Do not
use outdoors or on wet surfaces.
This appliance is not intended for use by persons
(including children) with reduced physical, sensory
or mental capabilities, or lack of experience and
knowledge, unless they have been given supervision or
instruction concerning use of the appliance by a person
responsible for their safety.
GENERAL PRECAUTIONS.
When using an electrical appliance, basic precautions
should always be followed, including the following:
Do not allow to be used as a toy. Close attention is
necessary when used near children. Children should
be supervised to ensure that they do not play with the
appliance.
If the appliance is not functioning properly, has been
dropped, damaged, left outdoors, or immersed in liquid,
do not use, contact DOMU Brands Customer Services.
Do not use the appliance if any parts appear to be faulty,
missing or damaged.
Ensure all parts are securely attached before using the
appliance.
CABLES AND PLUGS.
Check to ensure your electricity supply matches that
shown on the rating plate. The appliance must only be
used as rated.
Ensure the unit is disconnected from the main outlet
before cleaning.
The use of an extension cable is not recommended.
Do not let cord hang over the edge of the table or
counter-top where it could be pulled on inadvertently
by children or pets, or touch hot surfaces which could
damage the cord.
Do not pull the cable around sharp edges or corners.
Keep the cord away from heated surfaces.
Turn off all controls before unplugging.
Do not unplug by pulling on cable. To unplug, grasp the
adaptor, not the cable.
Ensure the cable is stored safely to prevent hazards.
The appliance shall be installed in accordance with
local/national wire regulations.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 2500446 and is the answer not in the manual?

Questions and answers

Summary of Contents for VonHaus 2500446

  • Page 1 2500446 Please read all instructions carefully before use and retain for future reference. Caution Risk of fire R290 Disconnect appliance from mains before cleaning, maintenance or after a thermal cut out event. Please read all instructions carefully before use and retain for future reference.
  • Page 2: Technical Specification

    If the supply cable is damaged, it must be replaced by a Do not cover or restrict the air flow of the inlet/ qualified engineer in order to avoid a hazard. outlet grills. RISK OF PERSONAL INJURY. For maximum performance ensure the minimum Always locate your appliance away from the edge of distance from walls or objects is be 20cm to any worktop, on a firm, flat, heat-resistant surface with...
  • Page 3 COMPONENTS 1. Control Panel. 2. 3 Colour Digital Display 3. Carry Handle. 4. Air outlet 5. Air Inlet with Filter. 6. Water Tank. 7. Continuous Drainage hole. 8. Overflow Pipe. 9. Power Supply. A5P | 01...
  • Page 4: Control Panel

    CONTROL PANEL POWER: : When the unit is powered on the indicators and LED will display for 1 second after a ‘‘buzz’’ is heard the power indicator will be in standby mode. Pressing the Power Button will start the unit in default mode the fan will start and the display will indicate the current room humidity and also colour corresponding .
  • Page 5: Lcd Panel

    LCD PANEL Continuous Mode is active Automatic Mode Sleep Mode On/Off indicator Timer is set Fan is on Low Fan is on High Button Lock is active Tank Full Indicator Humidity / Current Humidity POSITIONING When locating the Dehumidifier ensure its kept with at-least 30cm space all around the unit.
  • Page 6 WATER TANK & WATER DISPOSAL When the Water Tank is full the Indicator will display and the unit will stop automatically. Unplug from the mains and remove the tank by holding the grips either side and pulling away. NOTE: Do not set the tank down as the base is uneven.
  • Page 7 CLEANING THE FILTER (MONTHLY) Clean debris from the filter using a soft bristle brush then with clean running water do not use any detergents or abrasive chemicals, rinse the filter thoroughly and leave to completely dry for 24 hours CAUTION: Do not operate the unit without the fil- ter in place and ensure it is completely dry before re-installing.
  • Page 8: Maintenance

    MAINTENANCE 1.Checks to the area - the charge size in accordance with the room size within Prior to beginning work on systems containing which the refrigerant containing parts are installed; flammable refrigerants, safety checks are necessary to - the ventilation machinery and outlets are operating ensure that the risk of ignition is minimized for repair adequately and are not obstructed to the refrigerating system, the following precautions...
  • Page 9 MAINTENANCE 16.Decommissioning 13.Leak detection methods Before carrying out this procedure, it is essential that The following leak detection methods are acceptable technician is completely familiar with the equipment for systems containing flammable refrigerant. and all its detail. It is recommended good practice that Electronic leak detectors shall be used to detect all refrigerants are recovered safely.
  • Page 10 MAINTENANCE and that any associated electrical components are sealed to prevent ignition in the event of a refrigerant release. Consult manufacturer if in doubt. The recovered refrigerant shall be returned to the refrigerant supplier in the correct recovery cylinder, and the relevant Waste Transfer Note arranged. Do not mix refrigerants in recovery units and especially not in cylinders.
  • Page 11: Troubleshooting

    TROUBLESHOOTING Water Tank has not been fully inserted. No power to the unit Power Cord may be damaged. Contact Customer services. Ensure Water Tank is not full before use. Doors and windows may be open. Seal the room from external areas. Only small amounts of water being Water Tank has not been fully inserted.
  • Page 12 Should you require further assistance with your purchase, you can contact us at support@domu.co.uk VonHaus is a registered trademark of DOMU Brands Ltd. Made in China for DOMU Brands. M24 2RW. DISPOSAL INFORMATION Please recycle where facilities exist. Check with your local authority for recycling advice.