Download Print this page
Shinwa 72730 Instruction Manual

Shinwa 72730 Instruction Manual

Digital soil ph meter a-2

Advertisement

Quick Links

72730
Item Code 
Digital Soil pH Meter A-2
Instruction Manual
Thank you for purchasing Shinwa s 
Digital Soil pH Meter A-2. Before using 
the product, please read the instructions 
contained in this manual to ensure 
correct use. After having read this 
manual, always keep it with you or in a 
safe place.
-1-
■Use
●For simple measuring of soil acidity, soil temperature, moisture, salinity, 
and illuminance in the growing environment
■Features
●Non-slip elastomer construction, shaped for easy insertion into soil
●Easy-to-read LCD screen with large numbers and a wide viewing angle
●Mode switch on the front panel makes it easy to change between soil 
acidity* and temperature
●Backlight function
●Enables simple measurement of soil temperature, illuminance, soil moisture, 
and salinity
*Soil acidity displayed is the result of a chemical reaction between the measuring part and 
the soil s pH element, which is converted to a pH value.
■Part Names
●Front
Illuminance 
sensor
LCD 
screen
ON/OFF switch
Mode switch
Measuring 
part
Probe
(approx. 
10 cm)
-3-
●Back
注 意
●測定前に土壌に十
分水分を含ませて
からプローブの先
端1 0cmが土壌に
しっかりと密着す
るように挿してく
ださい。
●防水ではありませ
ん。 水で洗ったり、
雨に濡れたりしな
いように注意して
ください。
Battery 
cover
Cap 
*Remove cap when 
measuring
Caution
●Do not use other than as intended
●When measuring, sprinkle water on the soil and make sure that the soil is 
sufficiently moist so that it can adhere well to the measuring part
●This product is for soil only. Do not insert into water or any other liquid, as this 
may cause malfunction.
●Cannot be used with dry soil or soil containing significant humus, peat moss, 
kanuma soil, akadama soil, or sand that does not adhere to the measuring part
●Cannot measure accurately in small pots or other narrow environments
●Cannot measure alkalinity
●Measurements of illuminance, soil moisture, and salinity are simplified. Please 
use them as a guide.
●When measuring soil acidity, soil temperature, soil moisture, and salinity, 
remove the cap from the measuring part
●After spreading lime, etc. to adjust acidity, allow 1-2 weeks for it to mix into the 
soil before taking measurements. Otherwise, the soil may tend to be strongly 
acidic.
●When storing the device, clean the measuring part and replace the cap to 
protect it from oxidation
●Soil moisture is displayed by passing an electric current through the soil making 
contact with the measuring part, and quantifying it by its resistance value. The 
value shown may be lower than the actual value depending on the degree of 
adhesion to the soil.
●Do not allow the probe to remain inserted as this could cause it to corrode
●Do not bend the probe
●Do not loosen the clod of soil with the probe
●Do not allow the probe to come in contact with metal. When storing, make 
sure that it does not make contact with other metals.
●Before use, polish the measuring part (about 10 cm from the tip of the probe) 
with fine sandpaper (# 400-1000) to remove oxide
●Do not touch the measuring part with bare hands
●Do not drop or subject to strong impact
●Do not disassemble the device other than as directed in this manual
●This product is not waterproof. Do not wash with water or use in the rain.
●Do not use or store the product in an environment above 40° C
●Use a clean, soft cloth when wiping the product
●Remove the batteries when the device will not be used for a long period. It may 
break due to liquid leakage.
Shinwa Rules Co., Ltd.
3-18-21 Koya, Sanjo, Niigata, 955-8577 JAPAN
https://www.shinwasokutei.co.jp/english/
MADE IN CHINA
-2-
●Explanation of LCD screen
①PH (soil acidity) display 
Turns on when measuring soil acidity.
②Soil temperature display
Turns on when measuring soil temperature.
③PH, soil temperature measurement value display
Displays the measurement results.
* Lo  is displayed when exceeding the display rangeʼs 
lower limit.  HH  is displayed when exceeding the 
display rangeʼs upper limit.
④Low battery alarm
The battery icon will be displayed when the amount remaining is 3.65V.
⑤Illuminance display
⑥Soil moisture display
Displayed in 9 levels.
Displayed in 5 levels.
Display
Lux
Display
LOW−
under 500 Lux
DRY+
DRY
LOW
500 - 3,000 Lux
LOW+
3,000 - 7,000 Lux
NOR
NOR−
7,000 - 10,000 Lux
WET
WET+
NOR
10,000 - 25,000 Lux
NOR+
25,000 - 30,000 Lux
*For this device, soil moisture is defined as follows:
HGH−
30,000 - 40,000 Lux
Soil moisture (percent) = 
HGH
40,000 - 60,000 Lux
Weight of water / Weight of soil including water × 100
HGH+
over 60,000 Lux
■Specifications
Measuring Target
Soil Acidity, Soil temperature, Soil salinity, Soil moisture, Illuminance
Soil Acidity (12 levels)
pH3.5 - pH9.0 (minimum display pH0.5
Soil Temperature
5 - 40℃ (minimum display 1℃, accuracy ±1℃)
Soil Salinity (2 levels)
DRY+, DRY, NOR, WET, WET+
Soil Moisture (5 levels)
Illuminance
LOW−, LOW, LOW+, NOR−, NOR, 
(9 levels)
NOR+, HGH−, HGH, HGH+
3× AAA alkaline batteries 
Power Source
(Batteries included are for trial use only and may not last long.)
Auto Power Off
Turns off approximately 5 minutes after operation stops.
Auto Backlight Off
Backlight turns off approximately 1 minute after operation stops.
Temperature :  5 - 40℃          
Operating Temperature/
Humidity
Humidity :  5 - 95% (no condensation)
Body Size
293×60×37 mm  (Probe φ6×180 mm)
Weight
132 g (including batteries)
 *Displayed values are rounded up from 0.25 and rounded down from 0.24.
-4-
⑦Soil salinity display
Soil salinity is 
displayed in 2 levels.
Soil moisture
*
Soil salinity 
Display
display
under 5%
5 - 10%
DANGER
1.1% or more
10 - 20%
NOR
1.0% or less
20 - 3 0 %
over 30%
*
, accuracy ±pH0.5)
DANGER, NOR

Advertisement

loading
Need help?

Need help?

Do you have a question about the 72730 and is the answer not in the manual?

Questions and answers

Summary of Contents for Shinwa 72730

  • Page 1 ●Do not bend the probe correct use. After having read this  ●Do not loosen the clod of soil with the probe manual, always keep it with you or in a  ●Do not allow the probe to come in contact with metal. When storing, make  safe place. sure that it does not make contact with other metals. ●Before use, polish the measuring part (about 10 cm from the tip of the probe)  with fine sandpaper (# 400-1000) to remove oxide ●Do not touch the measuring part with bare hands ●Do not drop or subject to strong impact ●Do not disassemble the device other than as directed in this manual ●This product is not waterproof. Do not wash with water or use in the rain. ●Do not use or store the product in an environment above 40° C ●Use a clean, soft cloth when wiping the product ●Remove the batteries when the device will not be used for a long period. It may  break due to liquid leakage. Shinwa Rules Co., Ltd. 3-18-21 Koya, Sanjo, Niigata, 955-8577 JAPAN https://www.shinwasokutei.co.jp/english/ MADE IN CHINA ■Use ●Explanation of LCD screen ⑤ ①PH (soil acidity) display  ●For simple measuring of soil acidity, soil temperature, moisture, salinity,  Turns on when measuring soil acidity. and illuminance in the growing environment ① ② ②Soil temperature display ■Features ③ Turns on when measuring soil temperature. ④...
  • Page 2 ■Installing the Batteries over over Remove the insulating sheet that has been inserted and  Acidity becomes stronger Neutral Alkalinity becomes stronger install the batteries before using. ①Open the battery cover on the back of the device  and insert the batteries in the direction shown in the  figure on the right. ●Measuring soil temperature  ②Replace the battery cover. ①Insert the measuring part into the soil and push the ON/OFF  ■Before Using switch to turn on the device. ②Press the mode switch to change to the soil temperature  ●This product is designed to measure the soil  Fine-grained soil Coarse soil display. (field soil, etc.) (sandy soil, etc.) environment and cannot measure liquids or  non-soil materials ●Coarse-grained soil (humus, peat moss, sand,  etc.) cannot be measured accurately ●Measuring illuminance ●Gently pack soil around the measuring part so  that the soil closely adheres to it ①Insert the measuring part into the soil and push the ON/OFF  Pack soil around  Lightly polish  ●The measuring part is made of metal and may  switch to turn on the device. measuring about 10 cm oxidize. Oxidization will prevent the display of  ②Illuminance is displayed in 9 levels. part from the accurate values, so polish the measuring part ...