Serial Interface (RS-232C/RS-485) Specification
SW
FUNCTION
1
Emulation
Selection
2
3
Auto-Cutter
4
FONT SPACE
5
Function for
service
6
Engineer
7
8
RESERVED
SW
FUNCTION
1
Data Receive Error
2
Hexadecimal dump
3
Hand Shaking
4
Word length
5
Parity check
6
Parity selection
7
Baud Rate
selection
8
Transmission speed
NOTE : When the word length is 7 bits, you can not parity check OFF status.
DIP Switch 1 Setting
ON
Refer to the following table
Enable
2

Emulation mode selection

SW – 1
SW – 2
OFF
OFF
ON
Dip Switch 2 Setting
ON
Print "?"
YES
XON/OFF
7 bits
Enable
EVEN
Refer to the following table

Baud rate selection

1200 baud
2400 baud
4800 baud
9600 baud
OFF
Disable
3
MODE
OFF
Epson
ON
Citizen
OFF
Star
OFF
Ignore
NO
DTR/DSR
8 bits
Disable
ODD
SW – 7
ON
OFF
ON
OFF
13
DEFAULT
OFF
OFF
OFF
OFF
-
-
OFF
OFF
DEFAULT
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
SW – 8
ON
ON
OFF
OFF