SteREO Discovery.V12
For your safety
Observe the
following
instructions:
Controls and functional elements
NOTE: The microscope configuration shown here may vary from the existing configuration!
1 Binocular Ergo phototube S 5°-45° for mounting eyepieces and a camera using an adapter
2 Microscope body SteREO Discovery.V12
3 Dazzle protector, swing forward for use; when using the microscope with transmitted-light illumination
4 Transmitted-light unit S for use only in connection with cold-light source KL 1500 LCD / KL 2500 LCD for transmitted-light illumination
5 Support for glass plate with diameter 120 mm for objects or support of tables using adapter plate 84/120
6 Support for opal glass for transmitted-light illumination (diameter 84 mm)
7 Coded nosepiece 3 fold, coded or carrier S (not shown) for supporting the microscope body (support diameter 76 mm)
8 Oblique reflected-light illumination with flexible light guide and focussing attachment.
9 Illumination control for transmitted-light microscopy: see section Adjusting the illumination
10 System control panel S Y C O P ; for operation see section S Y C O P Touch screen controls
11 Foot pedal for focussing / zoom function
12 Control unit EMS-1 (component of S Y C O P ); connection of various functional units
13 Cold-light source KL 2500 LCD for reflected-light; see user instructions for setting and operating
14 Cold-light source KL 2500 LCD for transmitted-light; see user instructions; only in connection with transmitted-light unit S
15 Focussing control unit H I P (Human Interface Panel); power supply unit for operation without S Y C O P included in scope of supply
16 Motor focussing on the column; caution! During movement, keep your hands out of the movement area - crush hazard!
17 Zoom control unit H I P (Human Interface Panel); power supply unit for operation without S Y C O P included in scope of supply
Switching the device on
Switch-on procedure varies according to the existing configuration.
• Check that all cables are correctly plugged in.
• S Y C O P : Switch the rocker switch at the rear of the control unit
EMS-1 to I and press button
• H I P : Press button
(2).
NOTE:
Press button
switch into standby mode.
B 46-0008 e 12/06
The stereomicroscope SteREO Discovery.V12 including the original accessories may only be used for
the microscopy procedures described in these instructions and in the detailed Operating Manual.
The manufacturer accepts no liability if used for any other procedures.
Read the Operating Manual (B 46-0009) carefully; follow the safety instructions described here.
Connect the unit to the mains only at a correctly installed earthed socket.
Unplug the unit from the mains before opening it, and before changing a bulb or fuse.
Read the related user instructions before using any additional accessories.
When the motorised focussing is in motion there is a crush hazard!
During movement, keep your hands away from the movement area.
When using the microscope with transmitted-light there is a dazzle hazard.
Use the dazzle protector provided with the transmitted-light unit.
on the front (1).
on the control units EMS-1 (1) again to
Brief instructions for use
1
www.zeiss.de/stemi

Advertisement

loading
Need help?

Need help?

Do you have a question about the SteREO Discovery.V12 and is the answer not in the manual?

Questions and answers

Summary of Contents for Zeizz SteREO Discovery.V12

  • Page 1 Brief instructions for use − The stereomicroscope SteREO Discovery.V12 including the original accessories may only be used for the microscopy procedures described in these instructions and in the detailed Operating Manual. The manufacturer accepts no liability if used for any other procedures.
  • Page 2 HI P controls The H I P (Human Interface Panel) allows operation without S Y C O P . The first H I P is used for motorised focussing, the second H I P for zoom operation. If a S Y C O P is connected, the H I P is not necessary and is only of limited function.
  • Page 3 Adjusting the illumination Reflected-light illumination: • Connect the light guide for reflected-light to the cold-light source (RL) and attach it to the stand plate or nosepiece (or carrier S). Alternatively clamp the ring illuminator to the single objective (not to the nosepiece). •...