T E C H N O L O G Y F O R T H E W E L D E R ´ S W O R L D . EN Operating instructions ZH 操作手册 JA 取扱説明書 ® xFUME ADVANCED EN High-vacuum fume extraction system ZH 高真空排烟装置...
® xFUME ADVANCED Operating instructions Identification..........................EN-3 Marking .............................EN-3 Declaration of conformity.........................EN-3 Nameplate............................EN-4 Signs and symbols used ........................EN-4 Classification of the warnings ......................EN-4 Safety ..............................EN-5 Designated use..........................EN-5 Obligations of the operator ......................EN-5 Warning and notice signs ........................EN-6 Basic safety instructions ........................EN-6 Product-specific safety instructions....................EN-7 Safety instructions for the electrical power supply.................EN-7 Personal protective equipment......................EN-7...
® The xFUME ADVANCED fume extraction system is used for extracting fumes generated during welding, cutting and grinding processes. The device may be operated only with original ABICOR BINZEL spare ® parts. These operating instructions describe only the xFUME ADVANCED fume extraction system.
® 1 Identification xFUME ADVANCED 1.3 Nameplate Fig. 1 Nameplate The device is labeled by means of a nameplate on the housing. ► You will need the device type, device number and year of manufacture for inquiries. 1.4 Signs and symbols used The following signs and symbols are used in the operating instructions: General instructions.
® xFUME ADVANCED 2 Safety 2 Safety This chapter describes the essential safety requirements and warns of residual hazards that should be kept in mind to operate the product safely. Non-observance of the safety instructions may result in risks to the life and health of personnel, and environmental damage or material damage.
® 2 Safety xFUME ADVANCED 2.3 Warning and notice signs The following warning, notice and mandatory signs can be found on the product: ► Disconnect the mains plug. ► Wear a respiratory mask. ► Read and observe the operating instructions. Rotating fan blade warning.
® xFUME ADVANCED 2 Safety Safety instructions for welding ► Arc welding may cause damage to the eyes, skin and hearing. Note that other hazards may arise when the device is used with other welding components. Therefore, always wear the prescribed personal protective equipment as defined by local regulations.
® 3 Scope of delivery xFUME ADVANCED 3 Scope of delivery The following components are included in the scope of supply: ® — 1× xFUME ADVANCED fume extraction system — 1× current clamp — 1× power supply cable with safety plug —...
® xFUME ADVANCED 4 Product description 4 Product description 4.1 Assembly and use Fig. 2 Assembly and use A 2× turbines D 2× filter cartridges B 2× air intake fittings E Air exhaust louver C 4× castors The device is a component of a welding system. The device is used for manual welding and automated welding/robot welding.
® 4 Product description xFUME ADVANCED 4.2 Control elements and connections Fig. 3 Control elements/ports A Service LED F Mains connecting cable B Power LED G Output regulator C <Auto/Manual> switch H Compressed air connection D <On/Off> switch I Current clamp port 1 E Fuse J Current clamp port 2 <Auto/Manual>...
® xFUME ADVANCED 5 Transport and installation Tab. 2 Ambient conditions for transport, storage and operation Ambient temperature 0 °C to +40 °C (operation, storage in a closed environment) Ambient temperature (transport) −15 °C to +40 °C Relative humidity Up to 90% at +20 °C 5 Transport and installation WARNING Risk of injury due to improper transport and installation...
® 6 Commissioning xFUME ADVANCED 6 Commissioning WARNING Risk of injury due to fire Improper use or connection can result in fire. This may result in serious burns. ► Ensure that the operating voltage specified on the nameplate is suitable for the connection voltage. ►...
® xFUME ADVANCED 6 Commissioning 6.2 Mounting the current clamp A current clamp is supplied with the device. A second current clamp is optionally available for the connection of a second fume extraction torch. Connect the current clamp cable to the current clamp port.
® 7 Operation xFUME ADVANCED 115 V version The mains plug is not pre-attached. ► Attach and plug in an appropriate mains plug (customer-specific). 230 V version The power supply cable and mains plug are mounted. ► Plug in the power plug. 7 Operation WARNING Health risk caused by inhaling harmful dust...
® xFUME ADVANCED 7 Operation 7.1 Manual operation The device is operated in manual mode (deactivated automatic starting function) as follows: Fig. 3 Control elements/ports on page EN-10 Set the <Auto/Manual> switch to <Manual> to deactivate the automatic starting function. Set the <On/Off>...
® 7 Operation xFUME ADVANCED 7.2 Automatic mode The device is operated in automatic mode (activated automatic starting function) as follows: Fig. 3 Control elements/ports on page EN-10 If the welding process is interrupted, automated cleaning of the filter membranes occurs after a run-on time of 20 seconds.
® xFUME ADVANCED 8 Decommissioning 8 Decommissioning Turn the <On/Off> switch to <Off>. The filter membranes are cleaned once. Disconnect the current clamp. Disconnect the device from the power supply. 9 Maintenance and cleaning Scheduled maintenance and cleaning are prerequisites for a long service life and trouble-free operation. We recommend you clean the device in two steps.
® 9 Maintenance and cleaning xFUME ADVANCED CAUTION Risk of injury due to unexpected start If power is supplied during maintenance, cleaning or disassembly, rotating parts can start running unexpectedly and lead to injuries from cuts. ► Switch off the device. ►...
® xFUME ADVANCED 9 Maintenance and cleaning 9.2 Emptying the dust collecting drawer WARNING Health risk caused by inhaling harmful dust Improper emptying of the dust collecting drawer can lead to harmful dust and debris penetrating the ambient air. It can harm the respiratory tract if inhaled. ►...
® 9 Maintenance and cleaning xFUME ADVANCED 9.3 Replacing filter cartridges NOTICE Damage to the rotary nozzle Damage to the rotary nozzle due to improper removal and replacement of filter cartridges. ► Unscrew the filter cartridges without tilting and remove the filter cartridges concentrically from the housing, avoiding contact with the rotary nozzle.
® xFUME ADVANCED 9 Maintenance and cleaning Screw in the filter cartridges. Ensure that the filter cartridges are not tilted. Position the top panel in place and secure with clamps on both sides. 9.4 Replacing the carbon brushes WARNING Electric shock due to electronic component damage When replacing carbon brushes and turbines, electrical connections must be disconnected and reconnected.
Page 22
® 9 Maintenance and cleaning xFUME ADVANCED Remove the carbon brush covers (2×). Remove the connecting cable lug from the carbon brushes (4×). Remove the carbon brushes. Dispose of the carbon brushes in accordance with local regulations. 12 Disposal on page EN-26 Insert the new carbon brushes and mount again in reverse order.
® xFUME ADVANCED 9 Maintenance and cleaning 9.5 Replacing the turbines WARNING Electric shock due to electronic component damage When replacing carbon brushes and turbines, electrical connections must be disconnected and reconnected. Fatal electric shock may occur if electronic components become damaged or improperly uninstalled in the process.
► Immediately remove dust deposits from the environment with a dust class H industrial vacuum cleaner or a damp cloth. ► Observe the documentation for the welding components. ► Contact your retailer or ABICOR BINZEL in the event of questions or problems. Tab. 3 Faults and troubleshooting...
® xFUME ADVANCED 11 Disassembly 11 Disassembly CAUTION Risk of injury due to unexpected start If power is supplied during maintenance, cleaning or disassembly, rotating parts can start running unexpectedly and lead to injuries from cuts. ► Switch off the device. ►...
► Observe the local and official regulations. 12.4 Packaging ABICOR BINZEL has reduced the transport packaging to the necessary minimum. The ability to recycle packaging materials is always considered during their selection. EN - 26...
If ABICOR BINZEL is responsible for a defect that is present, ABICOR BINZEL is obliged to remedy the defect or deliver a replacement at its own cost and its own discretion. The warranty covers manufacturing faults, but not damage resulting from natural wear and tear, overloading or improper use.