ABB ADS420 Operating	 Instruction

ABB ADS420 Operating Instruction

Dissolved oxygen probe
Hide thumbs Also See for ADS420:

Advertisement

Quick Links

A B B M E A S U R E M E N T & A N A LY T I C S | O P E R AT I N G I N S T R U C T I O N | O I/A D S 4 2 0 - E N R E V. A
ADS420
Dissolved oxygen probe
Introduction
The ADS420 probe is a rugged, reliable instrument
ADS420
designed to deliver accurate dissolved oxygen (DO)
dissolved oxygen probe
data across a wide measurement range, using the
latest optical technology for DO measurement.
The probe is designed for use with ABB multi-input
transmitters, such as the AWT420 and AWT440,
which feature 'hot-plugging' capability.
Hot-plugging lets new or replacement sensors to be
connected without needing to power down the
transmitter.
When used in conjunction with the optional EZClean
compressed air supply unit (connected to an ABB
adaptor nozzle or T-piece), a schedule can be
configured to provide automatic in-situ cleaning of
the probe.
Optical dissolved oxygen probe
Measurement made easy
For more information
Further publications and publications for the
associated AWT420 and AWT440 transmitters are
available for free download from:
www.abb.com/measurement
or by scanning this code:
Data Sheet ADS420
Optical dissolved oxygen probe
Commissioning Instruction
AWT420
Universal 4-wire, dual-input transmitter
Operating Instruction
AWT420
Universal 4-wire, dual-input transmitter
Commissioning Instruction
AWT440
Multi-input transmitter
Operating Instruction
AWT440
Multi-input transmitter
CWA sensor accessories
Parts list
Search for or click on
DS/ADS420-EN
CI/AWT420-EN
OI/AWT420-EN
CI/AWT440-EN
OI/AWT440-EN
PL/ANAINST/001-EN

Advertisement

Table of Contents
loading

Summary of Contents for ABB ADS420

  • Page 1 Optical dissolved oxygen probe Measurement made easy Introduction For more information — The ADS420 probe is a rugged, reliable instrument Further publications and publications for the ADS420 designed to deliver accurate dissolved oxygen (DO) associated AWT420 and AWT440 transmitters are...
  • Page 2: Table Of Contents

    System overview . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 ADS420 cable attached ......5 ADS420 cable detached .
  • Page 3: Health & Safety

    ‘Note’ does not indicate a dangerous or harmful situation. Product recycling and disposal (Europe only) ABB is committed to ensuring that the risk of any Safety precautions environmental damage or pollution caused by any of Be sure to read, understand and follow the instructions its products is minimized as far as possible.
  • Page 4: Cybersecurity

    ABB and its affiliates are not liable for damages and/or losses related to such security breaches, any unauthorized access, interference, intrusion,...
  • Page 5: System Overview

    A D S 4 2 0 | D I S S O LV E D OX YG E N P R O B E | O I/A D S 4 2 0 - E N R E V. A System overview ADS420 cable attached ADS420 cable detached ADS420 probe components (cable attached) are shown in ADS420 probe components (cable detached) are shown in Figure 1: Figure 2:...
  • Page 6: Calibration

    A D S 4 2 0 | D I S S O LV E D OX YG E N P R O B E | O I/A D S 4 2 0 - E N R E V. A Calibration This section describes how to calibrate the probe and involves measuring the probe’s sensitivity to oxygen by exposing the probe to water-saturated air.
  • Page 7: 1-Point Calibration (Water-Saturated Air)

    A D S 4 2 0 | D I S S O LV E D OX YG E N P R O B E | O I/A D S 4 2 0 - E N R E V. A 1-Point calibration (water-saturated air) 1 Using a customer-supplied calibration pot, place a wetted 5 At the transmitter perform a 1-point calibration from an Operator page as follows:...
  • Page 8 A D S 4 2 0 | D I S S O LV E D OX YG E N P R O B E | O I/A D S 4 2 0 - E N R E V. A …3 Calibration …1-Point calibration (water-saturated air) 9 If 1-Point Cal is displayed, go to step 12.
  • Page 9: 2-Point Calibration (100 % And 0 % Saturation)

    A D S 4 2 0 | D I S S O LV E D OX YG E N P R O B E | O I/A D S 4 2 0 - E N R E V. A 2-Point calibration (100 % and 0 % saturation) Note .
  • Page 10 A D S 4 2 0 | D I S S O LV E D OX YG E N P R O B E | O I/A D S 4 2 0 - E N R E V. A …3 Calibration …2-Point calibration (100 % and 0 % saturation) 8 Use the 12 Press the...
  • Page 11: Abort Calibration

    A D S 4 2 0 | D I S S O LV E D OX YG E N P R O B E | O I/A D S 4 2 0 - E N R E V. A Abort calibration 18 When zero calibration is complete, a results page is displayed: key below the Abort...
  • Page 12: Maintenance

    A D S 4 2 0 | D I S S O LV E D OX YG E N P R O B E | O I/A D S 4 2 0 - E N R E V. A 4 Maintenance Cleaning the sensor cap Cleaning the optical lens 1 Remove the sensor from the process.
  • Page 13: Cleaning The Probe Body

    A D S 4 2 0 | D I S S O LV E D OX YG E N P R O B E | O I/A D S 4 2 0 - E N R E V. A Cleaning the probe body Diagnostic messages Note .
  • Page 14: Spares

    A D S 4 2 0 | D I S S O LV E D OX YG E N P R O B E | O I/A D S 4 2 0 - E N R E V. A 5 Spares EZLink extension cables Part number Description...
  • Page 15 A D S 4 2 0 | D I S S O LV E D OX YG E N P R O B E | O I/A D S 4 2 0 - E N R E V. A Acknowledgements • EZLink is a trademark of ABB Limited.
  • Page 16 We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document.

Table of Contents