Manual No: 576013-589  Revision: F
Overfill Alarm
Installation Guide

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Overfill Alarm and is the answer not in the manual?

Questions and answers

Summary of Contents for Veeder-Root Overfill Alarm

  • Page 1 Manual No: 576013-589  Revision: F Overfill Alarm Installation Guide...
  • Page 2 Customer Service will work with production facility to have the replacement product shipped as soon as possible. If “lost” equipment is delivered at a later date and is not needed, Veeder-Root will allow a Return to Stock without a restocking fee.
  • Page 3: Table Of Contents

    Enclosure Grounding ......................7 Setup and Test Setting Overfill Alarm Horn Delay Time ................9 Testing the Overfill Alarm with the Acknowledgment Switch ..........9 Setting the Overfill Alarm Horn’s Volume Level ..............9 Testing the Overfill Alarm with the Console ..............9 Testing Overfill Alarm W/o Acknowledgment Switch..........10 Testing Overfill Alarm With Acknowledgment Switch ..........10...
  • Page 4: Compatible Consoles

    577013-879 TLS-4XX Site Prep Manual Contractor Certification Requirements Veeder-Root requires the following minimum training certifications for contractors who will install and setup the equipment discussed in this manual: Service Technician Certification (Previously known as Level 2/3): Contractors holding valid Technician...
  • Page 5: Safety Symbols

    Veeder-Root TLS-450 Series Tank Monitoring Systems, including Line Leak Detection and associated accessories. All service personal on site must comply with all recommended safety practices identified by OSHA and your employer.
  • Page 6: Safety Warnings

    ENVIRONMENT, RESULTING IN SERIOUS INJURY OR DEATH. Fire or explosion resulting in serious injury or death could result if the Overfill Alarm and Ack switch units are installed in a volatile, combustible or explosive (Class I, Division I and Division II) atmosphere.
  • Page 7: Mounting Instructions

    Mounting Instructions Overfill Alarm and Acknowledgment Switch Dimensions Figure 1 shows the Overfill Alarm mounting dimensions and Figure 2 shows the Acknowledgment Switch mounting dimensions. 6'' (152.4 mm) 0.313'' (8 mm) dia. 4 holes Red Flashing Light Hinge side 10.3 '' (261.9 mm)
  • Page 8: Mounting Instructions

    Mounting Instructions Overfill Alarm 1. Select a mounting location where the Overfill Alarm can be seen and heard clearly from the area where the fuel tanks are filled. In addition, consider the ease of routing interconnection conduit. 2. Locate and mark mounting holes using the hole pattern in Figure 1.
  • Page 9: Wiring Instructions

    Wiring Overfill Alarm with Acknowledgment Switch 1. Pull two wires from the switch to the Overfill Alarm. 2. Pull two wires for line and neutral from the switch to the power panel. 3. Pull one wire from the switch to the TLS Console for connection to the alarm relay.
  • Page 10: Wiring Overfill Alarm Without Acknowledgment Switch

    If using a properly grounded rigid metal conduit or equivalent to enclose the external wiring for the Overfill Alarm, the ground hub that terminates the conduit provides an adequate grounding provision for the Overfill Alarm.
  • Page 11: Figure 5. Overfill Alarm Ground Wire Termination

    Input Connection Connection Connection Connection Connection Relay Connector Overfill Alarm without Acknowledge Switch (see Figure 4) Overfill Alarm terminal 2 J6, 1 J5, 1 Line (from power panel) J6, 2 J5, 2 Overfill Alarm with Acknowledge Switch (see Figure 3)
  • Page 12: Setup And Test

    Setup and Test Setting Overfill Alarm Horn Delay Time 1. Loosen the four screws that secure the Overfill Alarm cover clamps to the case. Slide the clamps away from the retaining lip on the door. Open the door. 2. Locate the Horn Time Delay Relay (see Figure 3).
  • Page 13: Testing Overfill Alarm W/O Acknowledgment Switch

    1. Reapply power. If the Overfill Alarm was wired properly, the alarm horn will sound immediately followed by the red alarm light flashing. 2. Turn Off power to the console and to the Overfill Alarm. Remove the test jumper between the Output Relay connections.