Haag-Streit BM 900 Instructions For Use Manual

Haag-Streit BM 900 Instructions For Use Manual

Slit lamp
Hide thumbs Also See for BM 900:

Advertisement

SVENSKA
NEDERLANDS
ESPAÑOL
ITALIANO
FRANÇAIS
DEUTSCH
ENGLISH
PORTUGUÊS
INSTRUCTIONS FOR USE
Slit lamp
BM 900
¨
18. Edition / 2021 – 08
DOC. no. 1500 1500.1400209.04000
1
© HAAG-STREIT AG, 3098 Koeniz, Switzerland - HS-Doc. No. 1500.7200492-04180 – 18. Edition / 2021 – 08

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BM 900 and is the answer not in the manual?

Questions and answers

Summary of Contents for Haag-Streit BM 900

  • Page 1 ITALIANO FRANÇAIS DEUTSCH ENGLISH PORTUGUÊS INSTRUCTIONS FOR USE Slit lamp BM 900 ¨ 18. Edition / 2021 – 08 DOC. no. 1500 1500.1400209.04000 © HAAG-STREIT AG, 3098 Koeniz, Switzerland - HS-Doc. No. 1500.7200492-04180 – 18. Edition / 2021 – 08...
  • Page 2 This device is equipped with high intensity light emitting diodes. Excessive exposure of patients in treatment with certain medication may lead to phototoxic adverse reactions, due to higher photosensitivity. © HAAG-STREIT AG, 3098 Koeniz, Switzerland - HS-Doc. No. 1500.7200492-04180 – 18. Edition / 2021 – 08...
  • Page 3: Table Of Contents

    6.5 Fixation star ..........................11 ◦ 6.6 Microscope and eyepiece ......................12 ¥ 7 Decommissioning ........................12 ¥ 8 Technical data ..........................12 ◦ 8.1 Slit illumination ..........................12 © HAAG-STREIT AG, 3098 Koeniz, Switzerland - HS-Doc. No. 1500.7200492-04180 – 18. Edition / 2021 – 08...
  • Page 4: Safety

    Air pressure 800 hPa ... 1060 hPa • Only original Haag-Streit spare parts may be used. Relative humidity 30 % ... 90 % © HAAG-STREIT AG, 3098 Koeniz, Switzerland - HS-Doc. No. 1500.7200492-04180 – 18. Edition / 2021 – 08...
  • Page 5 • This device must only be operated by qualified personnel. The information, please refer to the 'Maintenance' chapter. owner is responsible for their training. © HAAG-STREIT AG, 3098 Koeniz, Switzerland - HS-Doc. No. 1500.7200492-04180 – 18. Edition / 2021 – 08...
  • Page 6: Reporting Obligation

    Date of manufacture Manufacturer Serial number Haag-Streit reference number © HAAG-STREIT AG, 3098 Koeniz, Switzerland - HS-Doc. No. 1500.7200492-04180 – 18. Edition / 2021 – 08...
  • Page 7: Clinical Benefit

    2.2.4 Contraindications There are no known contraindications. © HAAG-STREIT AG, 3098 Koeniz, Switzerland - HS-Doc. No. 1500.7200492-04180 – 18. Edition / 2021 – 08...
  • Page 8: Introduction

    13. Breath shield (option) 29. Rail cover 14. Protective cover 30. Control lever 15. Illumination unit / microscope 31. Slide plate angle scale © HAAG-STREIT AG, 3098 Koeniz, Switzerland - HS-Doc. No. 1500.7200492-04180 – 18. Edition / 2021 – 08...
  • Page 9: Device Assembly / Installation

    (+) to the (−) side at low magnification. • The pupil distance should then be set on the microscope. © HAAG-STREIT AG, 3098 Koeniz, Switzerland - HS-Doc. No. 1500.7200492-04180 – 18. Edition / 2021 – 08...
  • Page 10: Preparing The Patient

    3° and 10°, a short mirror (12) is used, the illumination turned 90° using the locking screw (20) and tilted in 5° © HAAG-STREIT AG, 3098 Koeniz, Switzerland - HS-Doc. No. 1500.7200492-04180 – 18. Edition / 2021 – 08...
  • Page 11: Setting The Filters & Diaphragms

    Similarly, it is also possible to identify microstrabismus with the projection of the fixation star. The fixation star is usually used with an upstream red removal filter. © HAAG-STREIT AG, 3098 Koeniz, Switzerland - HS-Doc. No. 1500.7200492-04180 – 18. Edition / 2021 – 08...
  • Page 12: Stereo Microscope

    Magnification changer: 1× and 1.6× Magnif. with 10× eyepiece 10× and 16× (standard) Magnif. with 25× eyepiece 25× and 40× © HAAG-STREIT AG, 3098 Koeniz, Switzerland - HS-Doc. No. 1500.7200492-04180 – 18. Edition / 2021 – 08...
  • Page 13: Instrument Base

    • Do not use sprays. The LED illumination can be operated maintenance-free for its entire service life. © HAAG-STREIT AG, 3098 Koeniz, Switzerland - HS-Doc. No. 1500.7200492-04180 – 18. Edition / 2021 – 08...
  • Page 14: Replacing The Illumination Mirror

    Please refer to the instructions for use 'Applanation tonometer AT 900 / AT 870' and 'Applanation tonometer AT 900 D' Headrest Please refer to the instructions for use 'Headrest' © HAAG-STREIT AG, 3098 Koeniz, Switzerland - HS-Doc. No. 1500.7200492-04180 – 18. Edition / 2021 – 08...
  • Page 15: Legal Regulations

    13th August 2005. For correct disposal, please contact your Haag- Streit representative. This will guarantee that no hazardous substances enter the environment and that valuable raw materials are recycled. © HAAG-STREIT AG, 3098 Koeniz, Switzerland - HS-Doc. No. 1500.7200492-04180 – 18. Edition / 2021 – 08...
  • Page 16: Emitted Interference

    Harmonics emissions Not applicable IEC 61000-3-2 Voltage fluctuations/flicker emissions Not applicable IEC 61000-3-3 © HAAG-STREIT AG, 3098 Koeniz, Switzerland - HS-Doc. No. 1500.7200492-04180 – 18. Edition / 2021 – 08...
  • Page 17: Electromagnetic Immunity Environment Tested (Part 1)

    Power frequency magnetic fields should be at levels magnetic field 50/60 Hz 50/60 Hz characteristic of a typical location in a typical IEC 61000-4-8 commercial or hospital environment. © HAAG-STREIT AG, 3098 Koeniz, Switzerland - HS-Doc. No. 1500.7200492-04180 – 18. Edition / 2021 – 08...
  • Page 18: Electromagnetic Immunity Environment Tested (Part 2)

    GSM 800/900: max 2 W 50% PM 18 Hz 50% PM 18 Hz TETRA 800: max 2 W iDEN 820: max 2 W © HAAG-STREIT AG, 3098 Koeniz, Switzerland - HS-Doc. No. 1500.7200492-04180 – 18. Edition / 2021 – 08...
  • Page 19 If the measured field strength in the location in which this product is used exceeds the applicable RF compliance level above, this product should be observed to verify normal operation. If abnormal performance is observed, additional measures may be necessary, such as reorienting or relocating this product. © HAAG-STREIT AG, 3098 Koeniz, Switzerland - HS-Doc. No. 1500.7200492-04180 – 18. Edition / 2021 – 08...
  • Page 20: Equipment And This Product

    18.07 – 18.17 MHz, 21.0 – 21.4 MHz, 24.89 – 24.99 MHz, 28.0 – 29.7 MHz, 50.0 – 54.0 MHz. ** Formulas coming from Edition 3 of the IEC 60601-1-2. © HAAG-STREIT AG, 3098 Koeniz, Switzerland - HS-Doc. No. 1500.7200492-04180 – 18. Edition / 2021 – 08...
  • Page 21 NEDERLANDS ESPAÑOL ITALIANO FRANÇAIS DEUTSCH ENGLISH PORTUGUÊS Should you have any further questions, please contact your Haag-Streit representative at: Wiki Revision ID: 108518 © HAAG-STREIT AG, 3098 Koeniz, Switzerland - HS-Doc. No. 1500.7200492-04180 – 18. Edition / 2021 – 08...

Table of Contents