INTRODUCTION This manual provides instructions for the use and maintenance of Allegro Industries Com-pax-ial Blowers. You must read and understand this manual and be trained in the proper use of the equipment before using it in a contaminated atmosphere. There are many federal, state and local codes and regulations governing sales, construction, installation and/or use of products for certain purposes, which may vary.
DO verify that the blower uses appropriate electrical cord and NEMA plug. Electrically driven blowers (A.C.), are designed to operate ONLY from a grounded 115 volt AC, 60Hz single-phase power source. All electrical wiring installations and connections must comply with all applicable NEC statutes and with all applicable local codes and practices. (Consult current National Electric Code publications for specific information.) DO ground the blower motor securely.
Page 6
CAUTION! Before using the blower, check all applicable federal, state, industry and local regulations regarding the use of flame resistant and/or self-extinguishing duct materials for the intended job applications. It is the responsibility of the owner(s) and/or operator(s) to determine that the duct material in use for the job application meets all applicable fire code and OSHA requirements.
OPERATION Use of Duct: 1) Operate the blower upwind from the work location and with the air inlet facing into the relative wind to maximize air flow. 2) The Allegro flexible ducts are for use with Allegro blowers. a) All are of the retractable, non-collapsible design. b) Each duct is supplied with a nylon strap to secure each end to the blower and/or a duct connector.
Page 8
3) If Blower has an attached canister, verify canister and lid are secure before moving or storage. Release ducting lid and extend ducting before operating motor. 4) Maximum duct lengths will vary for each blower and environment. Generally, increasing lengths will decrease flow rates.
WARNING! GENERATOR USAGE It is important to use the proper size generator when powering a blower. Using an undersized generator may cause damage to the blower motor. Please refer to the Specifications section for a minimum generator recommendation. Use of a generator at the minimum recommended output with additional devises can cause decreased output or blower stoppage.
MAINTENANCE Maintenance & Repair: • Use only genuine Allegro approved, replacement parts for maintenance and repair. Use of parts manufactured by others can result in property damage and/or personal injury. • Always properly Follow the service instructions as outlined in the Maintenance section of this User’s Manual. maintain the blower.
LIMITED WARRANTY AND WARRANTY SERVICE AND RETURN POLICY Express Warranty The warranty obligations of Allegro Industries (“Allegro”) are limited to the terms set forth below: All products, equipment and parts (collectively “Product” or “Products”) sold by Allegro, either directly to its customers, or indirectly from its suppliers or distributors to their customers, are warranted, to the original end-user purchaser who/that receives the original, unaltered Product (“Purchaser”), to be free from defects in workmanship and materials under normal...
Page 12
The Purchaser may obtain this RMA# by telephoning Allegro’s Customer Service number at (800) 622-3530, or by requesting it in writing by mailing the written request to Allegro Industries, 1360 Shiloh Church Road, Piedmont, SC 29673, or by faxing the written request to Allegro Industries at (800) 362-7231.