Preface Preface To use this system correctly and safely and to ensure a long life, the user should thoroughly understand the functions, operations, instructions as well as its maintenance. Please read the information in this manual carefully before using the system. This system has been designed and manufactured safely for the operators and patients.
Page 6
Preface actual system that you purchase shall prevail. The company shall be responsible for accuracy and integrity of this Operation Manual. k) The company reserves the final right to interpret this Operation Manual.
Application Scope, Operation Conditions, Safety and Cautions Chapter 1 Application Scope, Operation Conditions, Safety and Cautions 1.1 Application Scope The system is a general-purpose diagnostic ultrasound imaging system designed exclusively for use in a wide variety of extracorporeal body imaging procedures. A general-purpose system supports various transducers and related application software packages allowing for the collection, display and analysis of ultrasound information.
Application Scope, Operation Conditions, Safety and Cautions away from these kind of radiated emissions or electromagnetic waves. Do not operate this system while other devices are operating with motor or silex switch in the same power phase; otherwise, noise will disturb your system through the power cable.
Application Scope, Operation Conditions, Safety and Cautions IEC60601-1-1; the removable multi-jack socket for the system shall comply with requirements of IEC60601-1-1 Appendix EEE; h) Do not place the removable multi-jack socket on the ground, otherwise, it may result in danger. The maximum load capacity of the removable multi-jack socket shall not be less than the total load of all the devices consisting of the system, or it may result in danger.
Application Scope, Operation Conditions, Safety and Cautions fixed position of the body for a long time; please check the display of acoustic output and MI, when powering on the system, input new patient ID or shift from non-fetal to fetal application. 1.5 Cautions While operating the system, please follow the methods and procedures described in this manual.
Page 11
Application Scope, Operation Conditions, Safety and Cautions EMC requirements, which might result in harmful interference to other device(s) in the environment For instructions on probe disinfection and protection, follow the description in 4.2.9. It is prohibited to scan eyes with the probe. Keep the acoustic power as low as reasonably achievable (ALARA).
The system shall not be applied to cardiology directly. Multiple devices, when interconnected, might result in accumulative leakage current and dangers. Make sure to use the special components provided by SIUI for system component repair or replacement. patient shield sheet...
Composition, Principle and Specification Chapter 2 Composition, Principle and Specification 2.1 Composition and Operation Principle 2.1.1 System Composition The system consists of a main unit, probes and peripheral devices. The main unit includes Probe Connector Board, Order and Amplification Board, Digital Processing Board, Control Platform, Operation Panel, Monitor and Power Supply.
Composition, Principle and Specification can be connected at the same time. The Data Processing Board generates transmit excitation signals of the current transmission to the Probe Connector Board after a series of processing including beam forming, aperture control dynamic apodization, dynamic filter, dynamic range conversion, demodulation, frame correlation processing and scan conversion, and transmitted to the ultrasound control platform through the Digital Processing Board.
Composition, Principle and Specification 2.2.17 System preset 2.2.18 Image Screen Display: a) Display all parameters related with diagnosis: system model, hospital name, patient name, patient ID, date, time and week, probe model exam type, and probe orientation; b) Display all the parameters related to imaging: acoustic output power(% or dB), depth, frame rate, imaging angle/ width, focus mark and range, gray scale, probe operating frequency, TGC curve, depth scale, gain, Smo/Edg, frame correlation, grayscale curve, dynamic range, zoom rate, line density and SRT.
Page 18
Introduction to Component Parts Chapter 3 Introduction to Component Parts 3.1 System Configuration 3.1.1 Basic Configuration a) Main unit (Monitor included): 1 set b) Probe: super broadband high-density multi-frequency convex probe: 1 pc 3.1.2 Accessories a) Power cable b) Potential equalization conductor c) Dust cover d) Fuse 【Note】: The specific accessories are subject to the Packing List.
Page 19
Introduction to Component Parts 3.1.3.5 Special system trolley 3.1.4 Connection to Peripheral Devices a) Video printer, VCR or large-screen monitor can be connected to the main unit via a cable with a high-frequency BNC plug; b) USB printer can be connected to the main unit via a USB port.
Page 20
Introduction to Component Parts 3.1.5 Outside Drawing of Main Unit (Fig. 3-1)...
Need help?
Do you have a question about the CTS-7700 and is the answer not in the manual?
Questions and answers