  • Page 1 Coway Air Purifier AP-1008DH · This product is for domestic use only.It cannot be used in an overseas country where the power voltage is different. · Warranty card is included in this user’s manual. · Read and save these instructions...
  • Page 2 FEATURES 1. MCC medium filter This is a versatile filter which removes the yellow dust that occurs during the spring season as well as toxic gases, viruses and bacteria such as influenza, legionella, etc. 2. Pollution level indicator/ mood lamp It has the function showing in the pollution level indicator by sensing the pollution of the indoor air automatically and added up to the interior-wise function.
  • Page 3: Table Of Contents

    DEAR CUSTOMERS coway air purifier. Thank you for using the Please read the user’s manual to use and maintain the product correctly. If you encounter a problem while using the product, you may easily solve the problem by referring to the user’s manual. As this manual contains the product warranty card, please keep it in a safe place.
  • Page 4: Safety Information

    SAFETY INFORMATION The following information is for user safety that should be observed. It is to ensure user safety and prevent property damage. Please read the precautions carefully and use the product correctly. If not observed, serious physical injury or property damage may Danger occur as a result.
  • Page 5: Installation Safety

    Remove any dust or water from the power plug. Otherwise electric shock or fire may occur as a result. Unplug the product if it is not to be used for a long time. Otherwise electric shock or fire may occur as a result. If the power cord is damaged, do not replace the cord yourself.
  • Page 6: Operation Safety

    SAFETY INFORMATION Operation Safety When the product is in use, maintain a distance of at least 20 cm from walls or adjacent objects and 30 cm - 60 cm above the product. Otherwise walls, ceilings, or surrounding objects may be contaminated.
  • Page 7 Unplug the product before you clean it. Otherwise electric shock or fire may occur as a result. Do not stick fingers or foreign objects into the air inlet or outlet. Otherwise physical injury or product malfunction may occur as a result. When removing the front cover, exercise caution not to have part of you body or other...
  • Page 8: Parts Name

    PARTS NAME Front < AP-1008DH > Others Display part/ operation part Pollution level indicator/mood lamp Speed indicator Pollution sensor unit Filter replacement reset button User’s manual Rear Air outlet Handle Power cord...
  • Page 9: Air Purified Process

    AIR PURIFIED PROCESS ■ Pre-filter Treated with antibacterial materials, the pre-filter removes relatively large dust, mold, human hair, pet hair, and others. ■ MCC medium filter This is a versatile filter which removes the yellow dust that occurs during the spring season as well as toxic gases, viruses and bacteria such as influenza, legionella, etc.
  • Page 10: Preparations

    PREPARATIONS Please Check Before Use! The product is for 120 V ~ 60 Hz only. Make sure to connect the power plug to a grounded electric outlet (120 V ~ 60 Hz) dedicated to the product. How to install filter - Make sure to remove each filter’s plastic packing before installing filters.
  • Page 11: Operation/Indication Part

    OPERATION / INDICATION PART Indication Part Light sensor It is a sensor that detects light. Speed indicator By using the speed button, it is possible to select the airflow speed in 4 steps (Step 1 → Step 2 → Step 3 → Turbo) ∗...
  • Page 12 OPERATION / INDICATION PART Operation Part Power button and its indicator Use it to turn the product on/off. When the power is on, the indicator is turned on. ∗ To turn off the power, press and hold the power button for approximately 1 second. Mood button and its indicator Use it to turn mood lamp...
  • Page 13 It displays the current cleanliness (pollution) level of the room. Clean:Blue ∗ The cleanliness (pollution) level of the room is determined by the color at the end of the penetrating hole. Lightly polluted: Polluted: Highly Light purple Dark purple polluted : Red...
  • Page 14: How To Use

    HOW TO USE - Before operating the product, connect the power plug to a dedicated Tips - Once the power is turned on, you will see the previously used operation mode, ■ To operate the manual mode Press the power button and then select the speed of the wind by pressing the speed button.
  • Page 15 ■ To operate the silent mode Press the power button and then the silent button. In silent mode, the airflow speed is lowered below step 1 (lower rpm), making the environment quiet and pleasant. ■ To operate the sleep mode(available only in auto mode operation) If the surroundings are dark for 3 minutes or longer in auto mode operation, the product automatically switches to sleep...
  • Page 16: Adjust Particle Sensor

    ADJUST PARTICLE SENSOR How to Adjust the Sensitivity of the Pollution Sensor When the product is shipped out, the pollution sensor is set to standard sensitivity. If the pollution level stays at the highest level after 2 hours of operation or stays at the lowest level for more than 1 hour when the air does not seem clean, users can adjust the sensitivity of the pollution sensor as follows.
  • Page 17: Cleaning Method

    CLEANING METHOD - Always unplug the air purifier before cleaning the product. - Do not use detergents that contain organic solvents (solvent, thinner, etc), Tips bleach, chlorine, or abrasives. - Do not put the air purifier in water or spray water directly on it. ■...
  • Page 18: Filter

    CLEANING METHOD - Always unplug the product before cleaning the filter. - The pre-filter is reusable by removing dust or cleaning it with water. - If the pre-filter is not cleaned for a long time, the product performance may deteriorate. Tips - The HEPA filter are not reusable with cleaning.
  • Page 19: Filter Replacement

    FILTER REPLACEMENT ■ How to replace filters - Check that the ‘front’ sides of filters are in the correct direction. - To maintain optimal performance of the product, use original coway filters. - Always unplug the air purifier before replacing filters. ■...
  • Page 20: Troubleshooting

    TROUBLESHOOTING The air purifier may operate abnormally not because of the product malfunction but because of minor causes or the fact that the user is not familiar with the product use. In such a case, problems can be solved easily even without the help from the service center just by checking the following.
  • Page 21: Specification

    SPECIFICATION Product specification Model Rated voltage Phase Power consumption Product insulation grade Dust collection mode Safety feature Installation place Maximum volume of air Size Weight ▶ The specifications are subject to minor changes to improve the product performance. Air Purifier AP-1008DH 120 V ~ 60 Hz 47 W...
  • Page 22: Warranty Card

    AP-1008BH/CH/DH...
  • Page 23 Add : WOONGJIN COWAY USA, INC. 695 SOUTH VERMONT, STE. 110(SOUTH TOWER) LOS ANGELES, CA 90005, USA Call Center : (213) 386-9900 / (213) 480-1600 FAX : (213) 386-3990...
  • Page 24 www.coway.com MADE IN KOREA 1209669...