LED
L1
P1
R1
SCALANCE W760 / W720
Operating Instructions, 03/2022, C79000-G8976-C322-13
Color
Meaning
Off
Power supply L1 too low.
Green
Power supply L1 is applied.
Off
There is no connection over the Ethernet port P1.
Green
There is a connection over the Ethernet port P1 (link).
Flashing green
Data transfer over the Ethernet interface P1.
and yellow
Off
The WLAN interface 1 is deactivated.
Access point mode:
Green
The WLAN interface 1 is initialized and ready for operation.
Client mode:
There is a connection over the WLAN interface 1.
Flashing green
Data transfer via the WLAN interface 1.
and yellow
Client mode:
Flashing yellow
The client is searching for a connection to an access point.
Access point mode:
Flashing yellow
With DFS (802.11h), the channel is scanned for one minute for
competing radar signals before the channel can be used for data
traffic.
Interval:
Client mode:
100 ms on /
The client waits for the MAC address due to the setting "Automatic"
100 ms off
for the "MAC mode" parameter and is not connected to an access
point.
Client mode:
Flashing yellow
and green
The client waits for the MAC address due to the setting "Automatic"
for the "MAC mode" parameter and is connected to an access point.
Interval:
3x (100 ms on /
100 ms off)
1x 1000 ms on