Table for information requirements for electric local space heaters
Model identifier(s): NTH20-20JRA
Item
Heat output
Nominal heat
output
Minimum heat
output (indicative)
Maximum
continuous heat
output
Auxiliary electricity consumption
At nominal heat
output
At minimum heat
output
In standby mode
Contact details:
Remark:
For electric local space heaters, the measured seasonal space heating energy efficiency ηs cannot be
worse than the declared value at the nominal heat output of the unit.
The seasonal space heating energy efficiency of all local space heaters
except commercial local space heaters, η
Symbol
Value
Unit
Pnom
2,0
kW
Pmin
1,2
kW
Pmax
2,0
kW
elmax
2008
kW
elmin
1251
kW
elSB
0.34
W
GD Midea Environment Appliances MFG. Co., Ltd.
No. 28, Dong Fu Road, He Sui East Industrial Area, Dong Feng Town, Zhongshan,
Guangdong, China
(%)
s
Item
Type of heat input, for electric local space heaters
only (select one)
Manual heat charge control with
integrated thermostat
Manual heat charge control with room
and/or outdoor temperature feedback
Electronic heat charge control with room
and/or outdoor temperature feedback
Fan assisted heat output
Type of heat output/room temperature control (select
one)
Single stage heat output and no room
temperature control
Two or more manual stages, no room
temperature control
With mechanic thermostat room
temperature control
With electronic room temperature control
Electronic room temperature control plus
day timer
Electronic room temperature control plus
week timer
Other control options (multiple selections possible)
Room temperature control, with
presence detection
Room temperature control, with open
window detection
With distance control option
With adaptive start control
With working time limitation
With black bulb sensor
5
P
Unit
[no]
[no]
[no]
[no]
[no]
[no]
[no]
[yes]
[no]
[no]
[no]
[no]
[no]
[no]
[no]