Airius ONYX Series Product Information & Installation Manual

Airius ONYX Series Product Information & Installation Manual

Hide thumbs Also See for ONYX Series:

Advertisement

Quick Links

PRODUCT INFORMATION &
INSTALLATION GUIDE
2021
Airius Model EC
ONYX SERIES
www.airius.co.uk
saving you energy

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ONYX Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Airius ONYX Series

  • Page 1 PRODUCT INFORMATION & INSTALLATION GUIDE 2021 Airius Model EC ONYX SERIES www.airius.co.uk saving you energy...
  • Page 2: Warranty

    Bacnet Protocol for individual fan control PC/ABS Resin - Inc. internal fixed blade stator For horizontal installations Airius recommend the use of the Airius proprietary cradle or a second cable or rod attachment to 5VA flame resistance rating the discharge end to provide balance...
  • Page 3: Operation

    Do not use petroleum products, thinners or solvents to clean any or lowered slightly. Contact Airius for design details and assistance. part of the Airius unit. The Airius unit performs best when air column from the nozzle is If the Airius unit fails, contact manufacturer. unimpeded to the floor.
  • Page 4 OS-EC-230V Product Information & Installation Guide ONYX SERIES - Model EC saving you energy CHAIN HUNG (STRAIGHT) PLUG NOT SUPPLIED To Control Module Unistrut or Ceiling Beam Cord Secured Receptacle Rated Chains should be rated @ 50 Kgs each 240 VAC (Not supplied).
  • Page 5 OS-EC-230V Product Information & Installation Guide ONYX SERIES - Model EC saving you energy CHAIN HUNG (ANGLED) PLUG NOT SUPPLIED To Control Module Nozzle cable Unistrut or Ceiling Beam secured Cord Secured Receptacle Rated 240 VAC 240 v Plug Chains should be rated @ 50 Kgs each (single phase) (Not supplied).
  • Page 6 OS-EC-230V Product Information & Installation Guide ONYX SERIES - Model EC saving you energy PEARLINK Reduce installation cost & control your Airius fan system over 2.4Ghz WiFi DISTRIBUTED COMFORT FEATURES The PearLink control system offers total fan control from a Interface is web-based (Chrome/Firefox), iOS, or Android »...
  • Page 7 OS-EC-230V Product Information & Installation Guide ONYX SERIES - Model EC saving you energy Housing: PC/ABS, Off white (cool gray 2c) Mounting: Factory installed at time of ordering. Power Consumption Idle: 16mA TX/RX: 200mA AIRIUS FAN SYSTEM Wi-Fi Characteristics 802.11b/g/n 2.4 GHz...
  • Page 8: Account Creation

    This is your command-and-control portal for the Airius fans at your facility. You can use the web based dashboard or the the Airius PearLink mobile app, available for both iOS and Android, to operate fans to fully control the air movement in a room.
  • Page 9: Provisioning Devices

    1.5-1.8 mts A.F.F. Preferably next to your existing thermostat. Open the Airius App and enter your email address and password to log in. You are now ready to provision your devices. Note: the screen shots are from an Android device and might vary slightly for iOS devices.
  • Page 10 OS-EC-230V Product Information & Installation Guide ONYX SERIES - Model EC saving you energy > > Name the device Continue Enter the associated invoice number > > Enter the ceiling height where the Review the information and select Select, “Add new device and apply most recent profile”...
  • Page 11: Device Control

    OS-EC-230V Product Information & Installation Guide ONYX SERIES - Model EC saving you energy DEVICE CONTROL The PearLink app allows for individual and group fan control. PearLink will monitor the air temperature at the fan and at the floor to provide a delta temperature. The humidity and air temperature will be logged and viewed within the app. This data can be exported as a csv file.
  • Page 12: Network Migration

    OS-EC-230V Product Information & Installation Guide ONYX SERIES - Model EC saving you energy NETWORK MIGRATION If you need to change your Wi-Fi network name or password for any reason, you must follow this process. If the name or password is changed before this step, the devices cannot be connected to. The only way to recover them is to revert back to the old network name and password.
  • Page 13 OS-EC-230V Product Information & Installation Guide ONYX SERIES - Model EC saving you energy BMS CONTROL WIRING GENERAL NOTES 0-10 V signal allows infinitely variable open loop speed control Connecting the red and yellow leads will allow EC fans to...
  • Page 14 OS-EC-230V Product Information & Installation Guide ONYX SERIES - Model EC saving you energy (0-10V) POTENTIOMETER EC FAN SPEED CONTROLLER Technical Data Voltage: 230VAC – 50/60Hz Output: 0-10 Vdc > 1 kOhm (max 8 mA) 1 X EC CONTROLLER REQUIRED PER CIRCUIT.
  • Page 15 OS-EC-230V Product Information & Installation Guide ONYX SERIES - Model EC saving you energy INSET MOUNTING (IP44) Break mains voltage. Connect according to diagram. Mount the inner case to the wall with the connections pointing down. Mount cover with nut to the wall. Push knob in place at off position.
  • Page 16 USA and foreign Patents granted to AIRIUS LLC, USA, further patents pending. AIRIUS & AIRIUS SYSTEMS is the copyright property of AIRIUS LLC, USA. All material issued by, or emanating from, Airius Europe Ltd is the Copyright property of Airius Europe Ltd, UK.