  • Page 1 USER MANUAL 2.2 B-EasyConnect Accessories for communication and IOT ─ S-02040102-0000 B-EasyConnect...
  • Page 2 You can reach us at: Berghof Automation GmbH Arbachtalstrasse 26 72800 Eningen Germany T +49.7121.894-0 F +49.7121.894-100 E-mail: controls@berghof.com https://www.berghof-automation.com Berghof Automation GmbH is certified according to DIN EN ISO 9001:2015. Berghof Automation GmbH | Arbachtalstrasse 26 | 72800 Eningen | www.berghof-automation.com...
  • Page 3 USER MANUAL 2.2 | B-EASYCONNECT Change Log Version Date Description 20.04.2020 First version 23.12.2020 First Revision 08.01.2021 Corrections added 20.01.2021 Opensource Licenses added Berghof Automation GmbH | Arbachtalstrasse 26 | 72800 Eningen | www.berghof-automation.com...
  • Page 4: Table Of Contents

    Interfaces ..........................17 Requirements for operation ....................18 CONFIGURATION....................... 19 Configuration of EasyConnect via Webinterface of the Berghof control system ..19 5.1.1 Configuration menu......................19 5.1.2 Changing/Setting EasyConnect operation mode ..............20 5.1.3 Operation as WLAN Access Point ..................21 5.1.4 Operation as WLAN Client Mode –...
  • Page 5 11.1 Declaration of conformity ....................31 CUSTOMER SERVICES / ADDRESSES ................33 12.1 Customer service ......................33 APPENDIX .......................... 34 13.1 Notes on copyright and license of the software ............34 Berghof Automation GmbH | Arbachtalstrasse 26 | 72800 Eningen | www.berghof-automation.com...
  • Page 6: General Information

    Safety  Mechanical design  Electrical design  Connections  Start-up  Upkeep and maintenance  Decommissioning  Disposal  Always keep this user handbook available alongside the product. Berghof Automation GmbH | Arbachtalstrasse 26 | 72800 Eningen | www.berghof-automation.com...
  • Page 7: Symbols And Visual Depictions

    Bold font in the text emphasizes important words  Example: Do not leave the page without saving. Design of warnings: WARNING Optional: Hazard type and source Other Short description and consequences Symbols  Preventive measures Berghof Automation GmbH | Arbachtalstrasse 26 | 72800 Eningen | www.berghof-automation.com...
  • Page 8: Hazard Categories And Indications

    Non-compliance with the safety features may result in minor injuries.  Take preventive measures. NOTE Possible damage to property Non-compliance with the safety features may result in damage to property.  Take preventive measures. Berghof Automation GmbH | Arbachtalstrasse 26 | 72800 Eningen | www.berghof-automation.com...
  • Page 9: Qualified Personnel

    The user always has any current relevant information regarding the device and its use or operation at his disposal. The user takes direct responsibility for agreeing with the competent authorities, the use of safety- related control components, and for compliance with their instructions. Berghof Automation GmbH | Arbachtalstrasse 26 | 72800 Eningen | www.berghof-automation.com...
  • Page 10: Handling Of Device

     If you discover damage in transport, or if the equipment delivered does not match the order: Inform the supplier immediately. Berghof Automation GmbH | Arbachtalstrasse 26 | 72800 Eningen | www.berghof-automation.com...
  • Page 11: Assembly

    Installing the device inside a metal control cabinet can lead to considerable loss of performance or even loss of radio communication.  Ensure that the device is operated outside a metal enclosure. Berghof Automation GmbH | Arbachtalstrasse 26 | 72800 Eningen | www.berghof-automation.com...
  • Page 12: Safety Instructions

     Do not install the operating equipment during a thunderstorm.  Wetness and liquids getting into the B-EasyConnect can cause electric shocks or short cir- cuits.  Do not allow any liquids to enter the interior of the operating equipment.
  • Page 13: Intended Use

    Correct transport, positioning, installation and use as well as careful maintenance are essential for the safe and reliable operation of the B-EasyConnect. The equipment must only be used under the conditions and in the applications specified in this documentation and the associated user manuals.
  • Page 14: Product Description

    Ethernet interface via USB enables modern means of communication and plant se- curity combined in one product. To use the B-EasyConnect, the Berghof controller requires a free USB connection port. The Gateway is powered via the USB cable, which is also used for USB communication with the controller. The user can now connect wirelessly to the Berghof control via the EasyConnect Gateway, e.g.
  • Page 15: Overview

    SD-card Slot (under protective flap) The SD card contains the operating system together with the Berghof application. The Berghof application only runs on the B-EasyConnect device, which is enabled for it. The SD card can not be transferred to another operating device.
  • Page 16: Scope Of Delivery

    USB 2.0, USB A connector to Micro USB B connector, black, 0,8m length  protective cap HDMI Mini PE with handle, plugged  protective cap USB Micro PE, plugged  Additional sheet with GPL License agreement Berghof Automation GmbH | Arbachtalstrasse 26 | 72800 Eningen | www.berghof-automation.com...
  • Page 17: Interfaces

     The other USB interface is used for power supply and data communication with a connected device (designation "USB" - standard interface for application). Fig. 2: Interfaces and connectors Berghof Automation GmbH | Arbachtalstrasse 26 | 72800 Eningen | www.berghof-automation.com...
  • Page 18: Requirements For Operation

    LED slow blinking (1 Hz) -> Startup and configuration of EasyConnect software Requirements for operation The following conditions must be met for operation of the B-EasyConnect with a compatible Berghof controller:  The corresponding micro SD card is inserted in the EasyConnect device.
  • Page 19: Configuration

    USER MANUAL 2.2 | B-EASYCONNECT Configuration The equipment is configured via the web interface of the Berghof control system, to which the B- EasyConnect gateway is connected. The configuration process is described in more detail in the following paragraphs. 5.1 Configuration of EasyConnect via Webinterface of the Berghof control system 5.1.1 Configuration menu...
  • Page 20: Changing/Setting Easyconnect Operation Mode

    3. WLAN client - the gateway or controller can connect to a compatible router or access point within range and establish communication. Berghof Automation GmbH | Arbachtalstrasse 26 | 72800 Eningen | www.berghof-automation.com...
  • Page 21: Operation As Wlan Access Point

    3. IMPORTANT: Select WLAN Country according to the operating location! 4. DHCP settings of the WLAN access point. 5. Accept and save the configuration - the settings are active after a restart of the controller. Berghof Automation GmbH | Arbachtalstrasse 26 | 72800 Eningen | www.berghof-automation.com...
  • Page 22: Operation As Wlan Client Mode - With Activated Dhcp

    3. DHCP Mode - the gateway (client) receives an IP address from the access point via DHCP. 4. Apply and save the configuration - the settings are active after a restart of the controller. Berghof Automation GmbH | Arbachtalstrasse 26 | 72800 Eningen | www.berghof-automation.com...
  • Page 23: Operation As Wlan Client Mode - With Static Ip-Address

    The IP address must not come from the DHCP range of the access point. Accept and save the configuration - the settings are active after a restart of the controller. Berghof Automation GmbH | Arbachtalstrasse 26 | 72800 Eningen | www.berghof-automation.com...
  • Page 24: Diagnostic Information

    5.2 Diagnostic information Fig. 8: Diagnostic log for connections The log file for the B-EasyConnect gateway can be viewed in the web interface using the corresponding menu item (e.g. for diagnostic purposes). Berghof Automation GmbH | Arbachtalstrasse 26 | 72800 Eningen |...
  • Page 25: Operation

    Do not plug, connect, disconnect or touch any connections during operation. Never remove the memory card during operation. Before working on the device, switch off or disconnect all power supplies, including those of connected peripherals (controller, programming devices, etc.). Berghof Automation GmbH | Arbachtalstrasse 26 | 72800 Eningen | www.berghof-automation.com...
  • Page 26: Service And Maintenance

    Do not use corrosive cleaning agents, thinners, abrasive cleaners or hard objects. Do not apply excessive pressure and do not bend or twist operating equipment. Do not place heavy, hard or sharp-edged objects on the device. Berghof Automation GmbH | Arbachtalstrasse 26 | 72800 Eningen | www.berghof-automation.com...
  • Page 27: Disassembly

     Send individual plastic parts for plastic recycling.  Sort electronic parts (printed circuit boards, drives, etc.).  Dispose of electronic scrap in accordance with national regulations and laws. Berghof Automation GmbH | Arbachtalstrasse 26 | 72800 Eningen | www.berghof-automation.com...
  • Page 28: Technical Data

    Max. 17,0dBm or 50 mW Transmission power USB Bus powered, no additional supply needed, power supply Power supply via USB cable from the connected controller(5 VDC ; 0,7 W) Berghof Automation GmbH | Arbachtalstraße 26 | 72800 Eningen | www.berghof-automation.com...
  • Page 29: Operation Conditions

    0 °C bis 55 °C ( when complying with the installation instructions) Relative humidity max. 85 %, non condensing Transport and storage –20 °C to +70 °C Ambient temperature Relative humidity max. 85 %, non condensing Berghof Automation GmbH | Arbachtalstrasse 26 | 72800 Eningen | www.berghof-automation.com...
  • Page 30: Supported Wi-Fi-Standards

    The net transmission speed corresponds to the transmission speed of the user data. Which standard is used in a WLAN depends on the settings of the base station. The B-EasyConnect must use the same standard and frequency band as the WiFi base station (router or access point).
  • Page 31: Product Conformity

    EN 61000-6-3:2007/AC:2011  EN 62311:2008  EN 62368-1:2014/AC:2015 11.1 Declaration of conformity Declarations of conformity are also available on our website. https://www.berghof-automation.com/downloads Navigate to the respective product for download. Berghof Automation GmbH | Arbachtalstrasse 26 | 72800 Eningen | www.berghof-automation.com...
  • Page 32 USER MANUAL 2.2 | HANDBUCH B-EASYCONNECT_V2_2_EN.DOCX Berghof Automation GmbH | Arbachtalstraße 26 | 72800 Eningen | www.berghof-automation.com...
  • Page 33: Customer Services / Addresses

    Repairs and corrective maintenance may be carried out only by the manufacturer or authorised customer service centres. 12.1 Customer service Berghof Automation GmbH Arbachtalstrasse 26 72800 Eningen Deutschland T +49.7121.894-183 F +49.7121.894-100 e-mail: support-controls@berghof.com www.berghof-automation.com Berghof Automation GmbH | Arbachtalstrasse 26 | 72800 Eningen | www.berghof-automation.com...
  • Page 34: Appendix

    (e.g.explicit product name, serial number etc.) will help us to identify the corresponding source code for you. The source code will be sent to the given address after reimbursement of the expenses actually incurred for providing the data carrier and shipping. Berghof Automation GmbH | Arbachtalstraße 26 | 72800 Eningen | www.berghof-automation.com...
  • Page 35 Fig. 6: Operation as WLAN-Client Mode – with activated DHCP ..........22 Fig. 7: Operation as WLAN-Client Mode – with static IP-Address ..........23 Fig. 8: Diagnostic log for connections .................... 24 Berghof Automation GmbH | Arbachtalstrasse 26 | 72800 Eningen | www.berghof-automation.com...