Electrical connection
7.4

Connecting electrical components

All cables from electrical components outside the boiler that are
connected to the plug-in strip must be routed to the inside via the strain
relief.
▶ Connect the connecting leads of the components to the plug-in strip
without tension.
▶ Route the connecting lead through the strain relief.
▶ Position the cable conduit [1].
Fig. 24 Positioning the connecting lead and cable conduit
7.5

Connecting the pump of the pump assembly

▶ Open the pump terminal unit.
20
1
0010035234-002
▶ Use the right screwdriver for this.
Fig. 25 Opening the pump terminal unit
With pump assembly:
▶ Connect the 230 V mains cable [1] of the pump to the 3-pin plug.
▶ Connect the PWM signal cable [2] of the pump to the 2-pin plug.
▶ Guide both cables through the strain relief.
▶ Connect the pump terminal unit: fold the pump terminal unit up and
press horizontally until it snaps into place.
Without pump assembly:
When using pump types other than those available from Bosch as
accessories, the PWM signal cannot be used. The PWM connection in the
pump terminal unit is then not used. On/Off operation applies for these
pumps.
▶ Connect the 230 V mains cable of the pump to the 3-pin plug [1].
▶ Guide the 230 V mains voltage cable through the strain relief.
Condens 7000 WP – 6721841195 (2022/01)