This document is provided “as is”. The contents of this document are subject to change without any notice. Please obtain the latest information through the Ruijie Networks website. Ruijie Networks endeavors to ensure content accuracy and will not shoulder any responsibility for losses and damages caused due to content omissions, inaccuracies or errors.
It is intended for the users who have some experience in instal ling and maintaining network hardware. At the same time, it is assumed that the users are already familiar with the related terms and concepts. Obtaining Technical Assistance Ruijie Networks Website: https://www.ruijienetworks.com/ Technical Support Website: https://ruijienetworks.com/support...
Page 4
PC to perform tasks including system commissioning, configuration, maintenance, management, and software loading. The RG-S5760C-X series switch is a class A product. In a domestic environment, this product may cause radio interference in which case the user may be required to take adequate measures.
SFP+ interface SFP module, SFP BIDI module SFP+ module, SFP+ cable, SFP+ BIDI module Optical Module See Appendix B. The supported module type may update at any time. Please consult Ruijie Networks for the latest information. 1 slot Expansion ...
Page 6
Hardware Installation and Reference Guide Overview Rated voltage: 100 to 240 V Maximum voltage: 90 to 264 V Frequency: 50/60 Hz Rated current per input: 3 A (150 W power supply) HVDC input: Rated voltage: 240 V DC Maximum voltage: 192 to 288 V DC Rated current per input: 3 A (150 W power supply) ...
Hardware Installation and Reference Guide Overview Storage humidity: 5% to 95% RH Altitude 0 to 5000 m (0 to 3.11 miles) Speed adjustment and fault alarm V1.X has 2 fans, and V2.X has 3 fans . Temperature Supported Alarm EMI Standard GB9254-2008CLASS A Safety Standard GB4943-2011...
Hardware Installation and Reference Guide Overview Note: 1. System LED 7. Port Status LED 2. Power Supply Status LED (PWR1) 8. 10GE SFP+ Port 3. Power Supply Status LED (PWR2) 9. USB Port 4. MGMT Port Status LED 10. MGMT Port 5.
Page 9
Hardware Installation and Reference Guide Overview Panel Identification Status Meaning The switch is not powered on. Blinking green Initialization is in progress. Continuous blinking (3 Hz) indicates a fault. It is used for on-site positioning of the device, Blinking green (10 and allows operation and maintenance personnel to perform remote power on and off control.
SFP+ interface SFP module, SFP BIDI module SFP+ module, SFP+ cable, SFP+ BIDI module Optical Module See Appendix B. The supported module type may update at any time. Please consult Ruijie Networks for the latest information. Expansion 1 slot...
Page 11
Hardware Installation and Reference Guide Overview Supported DC module: The switch supports RG-PD150IB- F after upgraded to 12.5SPJ4 or later versions. LVDC input: Rated voltage: -48 to -60 V DC Maximum voltage: -36 to -75 V DC Rated current per input: 5 A Supported SFP Port 10GE SFP Port Downward Compatible...
Page 12
Hardware Installation and Reference Guide Overview Safety Standard GB4943-2011 Dimensions 440 mm x 340 mm x 44 mm (17.32 in. x 13.39 in. x 1.73 in.) (W x D x H) Weight 4.5 kg (9.92 lbs.) Product Appearance RG-S5760C-48GT4XS-X Ethernet switch provides 48 10/100/1000Base-T Ethernet ports, 4 10GE SFP+ ports, 1 MGMT port, 1 USB port, and 1 Console port on the front panel, as well as 2 power supply module slots on the back panel.
Hardware Installation and Reference Guide Overview Note: 1. Grounding Lug 4. Power Supply Module Slot 1 2. Filler Panel 5. Power Supply Module Slot 1 3. Filler Panel (Non-expansion Module) Power Supply The RG-S5760C-48GT4XS-X supports two power supply modules. Dual-power input: The switch can be powered by one power supply module, or two power supply modules.
Page 14
Hardware Installation and Reference Guide Overview Panel Identification Status Meaning personnel to perform remote power on and off control. Solid green The switch is operational. Temperature alarm: 1. The temperature of inlet/outlet vent exceeds the warning threshold. Solid yellow 2. The power is insufficient for the system . Check the working environment of the switch and power supplies immediately.
Page 15
SFP+ interface SFP module, SFP BIDI module SFP+ module, SFP+ cable, SFP+ BIDI module Optical Module See Appendix B. The supported module type may update at any time. Please consult the Ruijie Networks for the latest information. Expansion 1 slot...
Page 16
Hardware Installation and Reference Guide Overview Rated current per input: 5 A 100Base-X SFP Port 1000Base-X 10GBbase-R SFP+ Port 1000Base-X Power < 77 W (without expansion module) Consumption < 102 W (with expansion module) V1.X (without expansion module): Operating temperature: 0º C to 45º C (32° F to 113° F) (altitude from 0 m to 1800 m (1.12 miles)) The highest operating temperature decreases by 1℃...
Page 17
Hardware Installation and Reference Guide Overview RG-S5760C-24SFP/8GT8XS-X Ethernet switch provides 24 GE SFP ports (port 17-24 do not support the rate of 100Mbps), 8 10/100/1000Base-T combo ports, 8 10GE SFP+ ports, 1 MGMT port, 1 USB port, and 1 Console port on the front panel, 2 power supply module slots and 1 expansion slot on the back panel.
Page 18
Hardware Installation and Reference Guide Overview S5760C-24SFP/8GT8XS-X supports two power supply modules. Dual-power input: The switch can be powered by one power supply module, or two power supply modules. When both two modules are working, the switch is working in power redundancy mode.
Hardware Installation and Reference Guide Overview Panel Identification Status Meaning The power supply module is not in place or not powered on. Power supply status The power supply module is in place and Solid green PWR1/PWR2 operational. The redundant power is faulty or the AC power Solid red cord is not connected.
Page 20
SFP+ module, SFP+ AOC cable, SFP+ BIDI module QSFP+ module, QSFP+ AOC cable QSFP28 module, QSFP28 AOC cable Optical Module See Appendix B. The supported module type may update at any time. Please consult the Ruijie Networks for the latest information. 10GBase-R SFP+ Port 1000Base-X...
Hardware Installation and Reference Guide Overview Figure 1-10 Front Panel of M5000X-4XS2CQ Module Note: 1. System Status LED 3. GE SFP+ Port Status LED 2. GE SFP+ Port 4. QSFP28 Port Panel Identification Status Meaning The switch is not powered on. Blinking green Initialization is in progress.
Hardware Installation and Reference Guide Overview RG-PD150IB-F is AC input (support LVDC) and DC output, and provides 12 V output voltage. The maximum voltage can reach 150 W. The switch can be powered by one power supply module, or two power supply modules. When both two modules are working, the switch is working in power redundancy mode.
Page 23
Hardware Installation and Reference Guide Overview Provides protection over over-voltage/current input/output, short-circuit output and so Protection I2C Communication Allows the host to communicate with the power supply module by I2C. Supports dual power supply modules to cooperate in parallel, enabling PE with 1+1 Power Supply Redundancy redundancy and redundant power supplies with current sharing.
Page 24
Hardware Installation and Reference Guide Overview I2C Communication Allows the host to communicate with the power supply module by I2C. Supports dual power supply modules to cooperate in parallel, enabling PE with 1+1 Power Supply Redundancy redundancy and redundant power supplies with current sharing. Supports to disconnect one redundant power supply module from the outside power Hot Swapping supply system, plug and unplug power supply modules while the device is powered...
2 Preparing for Installation 2.1 Safety Precautions To avoid personal injury and equipment damage, please carefully read the safety precautions before you install the RG-S5760C-X series. The following safety precautions may not cover all possible dangers. 2.1.1 General Safety Precautions ...
Keep the indoor installation environment clean and dust-free. Maintain appropriate humidity conditions. 2.1.5 Laser Safety Among the modules supported by the RG-S5760C-X series, here are many transceiver modules that are Class I laser products. Precaution: When a fiber transceiver works, ensure that the port has been connecte d with a fiber or covered by a dust cap to keep out dust and prevent it from burning your eyes .
Chlorine gas (CI 2.2.4 Grounding Requirements A good grounding system is the basis for stable and reliable running of the RG-S5760C-X series and is indispensable for preventing lightning strikes and interference. Please carefully check the grounding conditions at the installation site...
Hardware Installation and Reference Guide Preparing for Installation Correct grounding is the key to prevent lightning strikes and resist interference and must be performed by users. Safety Grounding Ensure that the switch are grounded through the yellow/green safety grounding cable when the device adopts the AC power supply.
Page 29
List of Tools Phillips screwdriver, flat-head screwdriver, wires, network cables, fastening bolts, Common Tools diagonal pliers, and binding straps Special Tools Anti-static tools Meters Multimeter The RG-S5760C-X series switch is delivered without a tool kit. Please prepare a tool kit yourself.
Hardware Installation and Reference Guide Installing the Switch 3 Installing the Switch Please ensure that you have carefully read Chapter 2 and make sure that the requirements in Chapter 2 are all met. 3.1 Installation Procedure 3.2 Preparing Before installation, please confirm the following requirements before installation: ...
3.3.1 Mounting the Switch into a Cabinet The RG-S5760C-X series switches follow the EIA standard dimensions and can be installed in 19-inch cabinet. During the installation, place the front panel on the front part of the bracket. For safety, fasten screws to secure the bracket on the switch, as shown in the 3-1.
Hardware Installation and Reference Guide Installing the Switch 3.3.2 Mounting the Switch on a Workbench If a standard 19-inch cabinet is unavailable, you can mount the switch onto a workbench with the following 2 steps. Attach the foot pads delivered with the switch to small holes at the bottom of the switch . ...
Hardware Installation and Reference Guide Installing the Switch Pull out the expansion module straightly and slowly. Do not hold the edge of the PCB or crash the components on the PCB. Install a filler panel in a vacant slot where an expansion module is removed to ensure normal ventilation and dissipation and avoid dust in the chassis.
Page 34
Hardware Installation and Reference Guide Installing the Switch Step 1: Press the latch to pull out the power supply module with one hand. Hold the power supply module with another hand. Step 2: Install a filler panel in the vacant slot and store the removed power supply module into its package. Figure 3-6 Removing a Power Supply Module Remove the power supply module straightly and slowly.
Hardware Installation and Reference Guide Installing the Switch 3.7 Connecting the External Interface Cables Precautions Correctly distinguish single-mode and multi-mode fibers and ports. Avoid bends of small curvature at the connector. Simple Connection Steps Step 1: Connect one end of the RJ45 connector to the Ethernet MGMT interface of the device board, and the other end to the NMS or a control terminal.
Connect the PC to the management port of the switch through a network cable, as shown in Figure 4 -1. Figure 4-1 Configuration Environment Connecting the Console Cable The RG-S5760C-X series switches adopt console cable connecting: Plug the DB-9 head of the console cable into the network port of the PC.
Page 37
Hardware Installation and Reference Guide Verifying Operating Status In the Connectivity Note window, enter the name of the new connection and click OK. A window appears as shown in Figure 4-3. In the Connect Using field, select the serial port you want to use. Figure 4-3 After selecting the serial port, click OK.
Page 38
Hardware Installation and Reference Guide Verifying Operating Status After setting the serial port parameters, click OK. The Hyperterminal window appears. 4.2 Checking Environment before/after Power-on Checking Environment before Power-on Check whether the switch is properly grounded. Check whether the power cord is properly connected. ...
Working status of fan and power supply Temperature status For the monitoring commands, refer to RG-S5760C-X Series Switch RGOS Configuration Guide. 5.2 Maintenance Ventilation System Maintenance The fan module responsible for heat dissipation is equipped with the fault monitoring signal. When the fan module is faulty, an alarm will occur.
Page 40
To replace lithium batteries, please contact technical support personnel of Ruijie Networks. The technical support personnel will s elect lithium batteries of the same specifications for replacement. Replacing Fuses To replace fuses, please contact technical support personnel Ruijie Networks. The technical support personnel will select fuses of the same specifications for replacement.
The system login password of the switch is forgotten or lost, and so it is not possible to configure the data. [Troubleshooting] Please contact Ruijie Customer Service Department for technical support. Fault 2: The AC power supply module does not work.
Page 42
RG-S6920-4C Software Configuration Guide. If not, modify the serial port configuration parameters. If there is still no serial port printed information, please contact Ruijie Custome r Service Department for technical support.
Page 43
Hardware Installation and Reference Guide Troubleshooting Check whether the optical module wavelengths of the two sides are consistent. For example, an optical module of 1310 nm wavelength cannot be connected to an optical module of 1550 nm wavelength. Check whether the distance between the two sides exceeds the length indicated on the optical module.
Hardware Installation and Reference Guide Appendix A Connectors and Media Appendix A Connectors and Media 1000BASE-T/100BASE-TX/10BASE-T Port The 1000BASE-T/100BASE-TX/10BASE-T is a port that supports adaptation of three rates, and automatic MDI/MDIX Crossover at these three rates. The 1000BASE-T complies with IEEE 802.3ab, and uses the cable of 100-ohm Category-5 or Supper Category-5 UTP or STP, which can be up to 100 m (328 feet).
Page 45
Hardware Installation and Reference Guide Appendix A Connectors and Media Optical Fiber Connection For the optical fiber ports, select single-mode or multiple-mode optical fibers for connection according to the fiber module connected. The connection schematic diagram is shown in Figure A-4: Figure A-4 Schematic Diagram for optical fiber connection...
Appendix B 10G SFP Modules Specifications Appendix B 10G SFP Modules Specifications Ruijie Networks provides various Gigabit SFP (Mini-GBIC modules), and 10G SFP+ transceivers for interfaces of modules on the switch. You can select the most suitable SFP transceivers as needed.
Page 47
Hardware Installation and Reference Guide Appendix B 10G SFP Modules Specifications GE-SFP-LX-SM1310 9/125 10 km MINI-GBIC-LH40-SM1310 9/125 40 km GE-SFP-SX-SM1310-BIDI 50/125 500m GE-SFP-SX-SM1550-BIDI 50/125 500m GE-SFP-LX20-SM1310-BIDI 9/125 20 km GE-SFP-LX20-SM1550-BIDI 9/125 20 km GE-SFP-LH40-SM1310-BIDI 9/125 40 km GE-SFP-LH40-SM1550-BIDI 9/125 40 km MINI-GBIC-ZX50-SM1550 9/125 50 km...
Page 49
Hardware Installation and Reference Guide 400 (OM1) 66 m XS-SFP-LR 9/125 10 km For XG-SFP-ER-SM1550 and XG-SFP-ZR-SM1550, do not use short-distant fibers in case of transceiver overload. If the light power received equals or exceeds -1dBm, add the optical attenuators to adjust the power as less than - 1dBm.
Hardware Installation and Reference Guide Appendix C Lightning Protection Appendix C Lightning Protection Installing AC Power Arrester (Lightning Protection Power Strip) The AC power port must be connected to an external lightning protection power strip to prevent the switch from being struck by lightning when the AC power cord is introduced from the outdoor and directly connected to the power port of the switch.
Page 51
Hardware Installation and Reference Guide Appendix C Lightning Protection Please connect an Ethernet port arrester to the switch to prevent the damage by lightning before connecting an outdoor network cable to the switch. Tools: Phillips screwdrivers or flat-head screwdriver, multimeter, and diagonal pliers Installation Steps: ...
Page 52
Hardware Installation and Reference Guide Appendix C Lightning Protection Incomplete arrester installation. If there is more than one port connected to the peer device on the switch, arresters need to be installed on all connection ports for the purpose of lightning protection.
Hardware Installation and Reference Guide Appendix D Cabling Appendix D Cabling When the RG-S5760C-X switch is installed in a standard 19-inch cabinet, secure the cables around the cable management brackets. Top cabling or bottom cabling is adopted according to the actual situation in the equipment room. All transferred cable connectors should be placed at the bottom of the cabinet in an orderly manner instead of outside the cabinet that is easy to touch.
Page 54
Hardware Installation and Reference Guide Appendix D Cabling Cables of different types (such as power cords, signal cables, and ground cables) should be separated in cabling and bundling. Mixed bundling is disallowed. When they are close to each other, it is recommended to adopt crossover cabling.
Page 55
Hardware Installation and Reference Guide Appendix D Cabling Cables not to be assembled or remaining parts of cables should be folded and placed in a proper position of the cabinet or cable trough. The proper position refers to a position that does not affect device running or damage the switch or cable.
Page 56
Hardware Installation and Reference Guide Appendix D Cabling Do not use self-tapping screws to fasten terminals. Power cables of the same type and in the same cabling direction should be bundled up into cable bunches, with cables in cable bunches clean and straight. ...
Hardware Installation and Reference Guide Appendix E Site Selection Appendix E Site Selection The equipment room should be at least 5 km away from heavy pollution sources, such as the smel ter works, coal mine, and thermal power plant. The equipment room should be at least 3.7 km away from medium pollution sources, such as the chemical factory, rubber factory, and electroplating factory.
Need help?
Do you have a question about the RG-S5760C-X Series and is the answer not in the manual?
Questions and answers