1. FUNCTION OVERVIEW
1. Support access and control by LED Player software or SN controller.
2. It supports 1,000,000 channels or cascade connection of 400 pieces controllers.
3. Use key of the controller to set the IP address of the controller.
4. 8-port data-independent signal output (with the isolation), control variety of regular chips in LED digital tube screen,
LED pixel light screen, and etc.
SW Single chip: D**S, D**J.
Single-wire: TM180*-400K/800K, UCS19**, UCS29**, WS2811/12, TLS3001(1Mhz), SM167**,
DMX512: SW-D, SW-U, UCS512A/B/C0/C4/D/E0/EH/G4/G6, DMX512AP/SM512,
Break-point resume: UCS5603, WS2818, GS8206, P9883, TM1914, XT1506S.
65536 gray scale: UCS8903, UCS8904, UCS9812, SM16813.
5. With professional LED Player software, user can make any effect by themselves.
6. The load capacity of different lighting fixtures is different. (If frame frequency is not required, load capacity of each
channel can be increased independently, and must test it in the factory.)
2. TECHNICAL PARAMETERS
Cover material: Iron
Input voltage: AC100V - 240V
Input signal: SW Ethernet Protocol
Output port: TTL & RS-485 * 8 ports
Pixel driven: Single chip: 2880 channels ×8 ports,
Output power: 5W
Working temperature: -15℃~60℃
Relative humidity: ≤50%
Connecting mode: In parallel (address manually)
IP grade: IP20 (Prevent people from touching the components inside electrical appliance, prevent
Working environment: 1.Please do not install the controller in magnetic, high pressure, high temperature or
SM16823E, SM16824E.
SM16500P/511/512, SM17500P/512P/522P, SM17512/522, SM18522P/PH,
Hi512A0/A4/A6, TM512AB3/AL1/ACx/AD/AE, QED512P, GS8512/513/515, standard
DMX512 lighting fixture on the market.
Please refer to the "CHIP SUPPORT" section for addressing.
Single-wire: 3072 channels ×8 ports,
Standard DMX512: 512 channels ×8 ports,
Extensible DMX: 1024 channels ×8 ports,
Break-point resume: 2160 channels ×8 ports,
65536 gray scale: 2160 channels ×8 ports.
object which diameter is more than 12.5mm from getting in, no special protection to water
or moisture.)
seriously wet environment.
2.Please do connect the earth safely in order to reduce risks of fire and damage which cause
by short circuit.
3.Please ensure AC100-240V power supply is used, and same polarity is connected between
transformer and controller in order to guarantee the proper supply voltage.
4.No waterproof function in the control system, please pay attention on rainproof and