Z
L
K
others
SCP-12
Bit
0
1
2
3
4
5
6
7
Command
ASCII
HEX
AWT35-100107 Rev AB
①general data
<STX> W
W
②if current weight is invalid
1
<STX>?<Status Byte><CR>
Simulate ZERO key:
5a
<STX>?<Status Byte><CR> ;
4c
Switch to and send standard weight. Same as W above
4b
Switch to and send metric weight. Same as W above
Un-known commands:
<STX>?<Status Byte><CR>
Status Byte1
0=Scale in motion
1=Stable
0= Scale at zero
1= Not at zero
0=RAM error
1= RAM okay
0= EEPROM error
1= EEPROM okay
Always 1
always 1
always 0
parity
<dp>W
W
W
<CR>
2
3
4
5
1 = Under capacity
0 = Not under capacity
1 = Over capacity
0 = Not over capacity
1 = ROM error
0 = ROM okay
1 = Faulty calibration
0 = Calibration okay
Response
Status Byte2
Always 1
always 1
always 0
parity
28/30