Mitsubishi Electric 800 Plus Series Safety Stop Function Instruction Manual page 7

Hide thumbs Also See for 800 Plus Series:

Advertisement

Internal
Input
safety
power
circuit
status
OFF
Normal
Normal
Normal
Normal
ON
Fault
Fault
Fault
Fault
∗1 ON: The transistor is conducted. OFF: The transistor is not conducted.
∗2 When not using the safety stop function, short across terminals S1 and PC, S2 and PC, and SIC and SD to use the inverter.
(In the initial status, terminals S1 and PC, S2 and PC, and SIC and SD are respectively shorted with shorting wires.)
∗3 If any of the faults shown in the following table occurs, terminal So (SO) and the SAFE signal turn OFF.
Fault
Option fault
Communication option fault
Parameter storage device fault
Retry count excess
Parameter storage device fault
Operation panel power supply short circuit/
RS-485 terminals power supply short circuit
24 VDC power fault
Safety circuit fault
Overspeed occurrence
∗4 When the internal safety circuit is operated normally, the terminal So (SO) and the SAFE signal remain ON until E.SAF is
displayed, and the terminal So (SO) and the SAFE signal turn OFF when E.SAF is displayed.
∗5 SA is displayed when the terminals S1 and S2 are identified as OFF due to the internal safety circuit failure.
∗6 If another fault occurs at the same time as E.SAF, the other fault can be displayed.
∗7 If another warning occurs at the same time as SA, the other warning can be displayed.
∗8
The ON/OFF state of the output signal is the one for the positive logic. The ON and OFF are reversed for the negative logic.
∗9 For the SAFE signal, refer to the following table and assign the function using Pr.190 to Pr.196 (output terminal function
selection).
SAFE
∗10 The use of SAFE signal has not been certified for compliance with safety standards.
NOTE
• The response time from safety stop signal input to drive shutoff (safe state) is faster than 8ms.
• Hold the ON or OFF status for 2 ms or longer to input signal to terminal S1 or S2.
Signal input shorter than 2 ms is not recognized.
6
INSTALLATION AND WIRING
Table 5 Truth table of safety related signals
Input terminal
,
∗1
∗2
S1
S2
OFF
ON
ON
ON
ON
OFF
OFF
OFF
ON
OFF
OFF
OFF
ON
ON
ON
OFF
ON
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
Operation panel indication
E.OPT
E.OP1 to E.OP3
E.PE
E.RET
E.PE2
E.CTE
E.P24
E.SAF
E.OS
Output
signal
80
Output
Output
signal
terminal
,
,
running status
∗8
∗9
∗10
So (SO)
SAFE
Output shutoff
OFF
(Safe state)
OFF
Drive enabled
∗3
Output shutoff
OFF
∗4
∗4
(Safe state)
Output shutoff
OFF
∗4
∗4
(Safe state)
Output shutoff
ON
∗3
∗3
(Safe state)
Output shutoff
OFF
(Safe state)
Output shutoff
OFF
(Safe state)
Output shutoff
OFF
(Safe state)
Output shutoff
OFF
(Safe state)
Speed deviation excess detection
Signal loss detection
Excessive position fault
Brake sequence fault
Encoder phase fault
CPU fault
Internal circuit fault
Pr.190 to Pr.196 settings
Positive logic
Operation panel
Inverter
indication
E.SAF
∗6
Not displayed Not displayed
Not displayed Not displayed
Displayed
Displayed
Not displayed Displayed
Displayed
Displayed
Displayed
Displayed
Fault
Operation panel indication
E.OSD
E.ECT
E.OD
E.MB1 to E.MB7
E.EP
E.CPU
E.5 to E.7
E.13
Negative logic
180
SA
∗7
Displayed
Displayed
Not
displayed
∗5
Displayed
Displayed
Displayed

Advertisement

loading

This manual is also suitable for:

A800 plusFr-a800-lc800 seriesFr-a800Fr-a870