REMOVE ROTOR ASSEMBLY FROM OUTER DRIVE ASSEMBLY
(E1-24, E1-32, E1-55, E1-69 and E1-82 Models)
1.
Attach the puller plate to the rotor assembly using three (3) of the pump's 12.7 mm (1/2") screws.
ATTACH PULLER PLATE
2.
Loosely fit the two (2) rods into opposite holes on the outer drive assembly.
3.
Loosely position the two rod ends into the channel.
4.
Twist the two rods to tighten the channel nuts that lock the rods to the channel.
ATTACH RODS AND CHANNEL
5.
Assemble the two (2) wing nuts onto the two (2) rods to hold them to the outer drive assembly.
6.
Carefully lift the outer drive assembly (with the tool kit attached) and set it on a suitable workbench vertically with the rotor
teeth facing up.
7.
Firmly affix the channel to the workbench surface so it can safely resist a lifting force of up to 182 kg (400 lb).
TOOL FULLY ASSEMBLED