5. MAINTENANCE
5.1.
Maintenance, service and repair should only be carried out by qualified persons.
5.2.
Clean the pump silencer at least once a month to remove oil residue. Remove it from the pump housing and place it in a detergent
solution for 2 hours. Dry it with compressed air and place it back in the pump housing.
5.3.
Check the condition of the transfer hoses. Make sure that they are intact and undamaged, without cracks, holes or leaks. If they are
damaged or they leak, replace them.
5.4.
Check the condition of the teflon gaskets and the 'fishbone' connections. Be sure that they are undamaged and can maintain a
perfect seal. Replace them with original spare parts if they are damaged or not working correctly.
5.5.
Periodically check the earth strap terminals for tightness and that the wire and clamps are in good order.
We, the sole importer into the UK, declare that the product listed below is in conformity with the following standards and directives.
Pneumatic Fuel Tank Drainer Model No: TP95
89/392/EEC
Machinery Directive (1992 SI No. 3073)
NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts
without prior notice.
IMPORTANT: No responsibility is accepted for incorrect use of this product.
WARRANTY: Guarantee is 12 months from purchase date. Proof of purchase will be required for any claim.
INFORMATION: Please call us for a copy of our latest catalogue
E
F
Declaration of Conformity
Signed by Tim Thompson
Sole UK Distributor
Sealey Group,
Bury St. Edmunds, Suffolk.
The construction file for these products is held by the Manufacturer
and may be inspected on request by contacting Jack Sealey Ltd
For Jack Sealey Ltd.
Sole importer into the UK of Sealey Power Products
01284 757500
01284 703534
1st March 2007
www.sealey.co.uk
Web
sales@sealey.co.uk
email

Advertisement

loading