Evergreen
VS User Interface
®
Evergreen VS Motor
Installation Guide
WARNING indicates a hazardous situation that, if not avoided, could
result in death or serious injury.
• Read and follow all instructions carefully.
• Disconnect and lock out the main power from the unit being
serviced before installing the Evergreen VS user interface and
motor. It is also a good practice to confirm that the power is
disconnected with a voltmeter.
• Do not operate equipment without guards in place.
• Improper installation, adjustment, alteration, service,
maintenance, or use could cause explosion, fire, electrical shock,
or other conditions. Consult a qualified installer, service agency,
or your distributor or branch for information or assistance.
The qualified installer or agency must use the supplied or
recommended parts when installing or servicing this product.
• After installing the Evergreen VS user interface and motor, it is
the responsibility of the installing technician to verify the HVAC
system matches the manufacturer's requirements for proper
operation, capacity, efficiency and safety. This includes but is not
limited to measuring the airflow and adjusting the Evergreen
VS user interface airflow and delay setting in each mode of
operation.

Table of Contents

Page
1.
Introduction
2.
Evergreen VS Product Line Applications
and How to ID Genteq ECM Motors
3.
and Removal and Installation of the Motor
4-5.
Installation of the Evergreen VS User Interface (UI)
6.
7 .
8.
9.
10-11.
12.
and Evergreen VS Motor Specifications
and Technical Support and Warranty
INTRODUCTION
The Evergreen VS motor is designed to replace Genteq constant airflow (variable speed) ECM motors. This includes ECM indoor
blower motors made by Regal and its predecessor manufacturer and sold under other Regal and predecessor manufacturer brands.
The Evergreen VS motor is a constant airflow (variable speed) motor. It will operate in constant airflow mode when it is receiving digital
serial interface (DSI) and constant torque mode when it is receiving pulse width modulation (PWM) communication.
1
©2019, 2020 Regal Beloit Corporation, All Rights Reserved. MCIM20008E • Form# G0075E
Regal Beloit America, Inc.
Customer Service: 800 672 6495
CAUTION indicates a hazardous situation that, if not avoided,
could result in minor or moderate injury.
• Periodic inspections should be performed. Failure to perform
proper maintenance could result in premature product failure, in
addition to minor or moderate injury.
• Installation and service of this Evergreen VS user interface and
motor should be performed only by trained service technicians
familiar with these products.
• This Evergreen VS user interface and motor should be
installed in accordance with accepted practices and installation
instructions, and in compliance with all national and local codes.
®
1325 Heil Quaker Blvd.
LaVergne, TN 37086
thedealertoolbox.com
www.regalbeloit.com
Evergreen
VS User Interface
®
Evergreen
VS Motor
®
F O R M
G0075E
Revised
January 2020

Advertisement

loading
Need help?

Need help?

Do you have a question about the Genteq Evergreen VS and is the answer not in the manual?

Questions and answers

Summary of Contents for Regal-Beloit Genteq Evergreen VS

  • Page 1: Table Of Contents

    Regal Beloit America, Inc. F O R M 1325 Heil Quaker Blvd. G0075E LaVergne, TN 37086 Evergreen VS User Interface ® Customer Service: 800 672 6495 Revised thedealertoolbox.com Evergreen VS Motor January 2020 www.regalbeloit.com Installation Guide WARNING indicates a hazardous situation that, if not avoided, could CAUTION indicates a hazardous situation that, if not avoided, result in death or serious injury.
  • Page 2 Applications - Evergreen VS Product Line ® The Evergreen VS motor can be used to replace multiple Genteq constant airflow motors either by itself or in conjunction with the ® correct accessory. Use the chart below to select the correct components for your application. NOTE: Use this manual to replace model 2.0, Genteq models 2.3 and Eon motors with Evergreen VS motor and User Interface.
  • Page 3 APPLICATIONS Replacing model 2.0, Genteq models 2.3 and Eon motors ® ® – Applications Furnace, air handler and package units Fossil fuel, electric strip heat, A/C, heat pump and geothermal units Single stage and/or two stage systems only Model 2.0 Genteq ECM Genteq ECM –...
  • Page 4: Model 2.0, Genteq Models 2.3 And Eon ® Applications

    INSTALLING THE EVERGREEN VS USER INTERFACE (UI) ® Install the UI so that the screen and buttons are accessible and visible. Orient the UI so that the thermostat wires face down in the HVAC system. There are three holes in each side wing for mounting, and there is two-sided tape on the back.
  • Page 5 Single Stage HVAC Systems with Two Stage HVAC Systems connected a Single Stage Thermostat to a Single Stage Thermostat Two Stage HVAC Systems connected to a Two Stage Thermostat The thermostat wire designations and connections legend are provided on either side of the thermostat wire harness decal. ©2019, 2020 Regal Beloit Corporation, All Rights Reserved.
  • Page 6: Evergreen Vs User Interface (Ui) Overview

    EVERGREEN VS USER INTERFACE (UI) OVERVIEW ® Thermostat LED – These lights indicate the current thermostat demand. The demand will also appear on the display screen. System LED – These lights indicate the outputs from the HVAC system control board on the 16-pin plug. The R(PWR) LED indicates the UI is receiving 24VAC from either the thermostat or the 16-pin plug.
  • Page 7: Sequence Of Operation

    SEQUENCE OF OPERATION No Demand from the Thermostat = No Operation from the UI Any thermostat demand at the UI will turn on the corresponding thermostat indicator LED. The display screen will populate the following information: – the thermostat demand (example: W1) –...
  • Page 8: Commissioning

    COMMISSIONING Operate the system in all modes of operation to confirm the thermostat wiring energizes the proper demand on the user interface and adjust the airflow values and on/off delay values if needed. The values shown on the display screens below, for each thermostat demand, represent the user interface factory default settings.
  • Page 9: Airflow And Delay Adjustments

    AIRFLOW AND DELAY ADJUSTMENTS The % AIRFLOW (%A/F) and the ON/OFF delays can only be adjusted when a thermostat demand is present at user interface. – Single stage systems – Operate the thermostat in heat or cool (heat pump) demand. –...
  • Page 10: Options Menu

    OPTIONS MENU This menu provides options that will enhance the ability of the user interface (UI) to match the operation of the motor to the operation of the HVAC system. To enter the options menu, press and hold the OPTIONS button for 10 seconds. The UI must be unlocked.
  • Page 11 OPTIONS MENU (Continued) – Motor Output Type = RPM This feature is only used to support the RPM or airflow indicator used on some HVAC system controls. This feature should be left at the default setting (Type=RPM) unless technical support advises otherwise. –...
  • Page 12: Evergreen Vs User Interface (Ui) Specifications

    EVERGREEN VS USER INTERFACE (UI) SPECIFICATIONS ® Dimensions: 5.5” x 3.35” x 1.25” Voltage Rating – Thermostat inputs are rated for 18-30 VAC Ambient Ratings – Operating Temp 0°C to 50°C (32°F to 122°F) – Storage Temp -20°C to 70°C (-4°F to 158°F) Lead Lengths –...