Breakdown Analysis And The Meansofoyerhauling; Examining The Breakdown Causes; Spotexaminingstepsofthemicrowaveoven - Galanz WP700AP17 Service Manual

Table of Contents

Advertisement

position.
(6) Fix the control panel on the oven (FIG.4-6).
(7) Pług in the terminal plugs of the PC board.
5 BREAKDOWN ANALYSIS AND THE MEANS OF OVERHAULIHG
Before overhauling a microwave oven, you should judge the breakdown and the cause correctly, then you can
repair it with corresponding ways. The overhauling must be proceed in order, any hasty conclusion is not
recommendable, otherwise over-working would be done when repair. The microwave oven may occur compound
breakdown due to all kinds of different reasons, thus, when overhaul, they all should be taken into consideration.
Special attention must be given to the microwave leakage and the electric insulation when examine because they
may do harmful to the repairing staff.
5.1
How to examine a microwave oven with breakdown? A better means which demonstrated in practical operating
analysie the break down quickly and correctly.
5.1.1
INSPECTION.
Inspect whether the oven shape is disordered and where is the disordered position, If any. It is normal if the
cabinet disordered a little, but abnormal if the oven, the door disordered, the door hook broken, the door crooked,
or there arę too much looseness between the door and the oven after the door is closed .
5.1.2
Listening to the sound of the oven operating and the noise of the fan. Minor "wen wen" noise, cycling"kala"noise
and "shishi" noise should be considered as normal. But it is abnormal if the following noises occur:
(1) Sound "wen wen " noise.
(2) Long time "shishi" noise.
(3) Strike sound like "Pipa pipa"
5.2
SPOT EXAMINING STEPS OF THE MICROWAVE
OVEN
5.2.1
insulating
megaohmmeter the value should not be less than 2 megaohms.
Otherwise, part examination should be taken at once. Such as
checking whether the motor, the thermal cutout, the transformer or
the capacitor arę electricity leaking.
5.2.2
the power pług haven't been plugged in ), measure the two feet (L -
N) of the power pług with Rxi grade of an avometer, the resistance value should be about 2.5 ohm. If open circuit
occurs, then you must check whether the 8A fuse is broken> the primary winding of the transformer is open
the plugs arę connected well. If short circuit occurred or the
resistance less than 1.5 ohms, you should check whether the
primary winding of the power transformer is short - circuited or part
5.2.3
Measure the microwave leakage with a microwave leakage measure.
resistance with
a
avometer or a
16
Fig. 5-1

Advertisement