Industrial infrared diesel heater

Advertisement

Quick Links

Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these
instructions, and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE
THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
Refer to
Wear protective
instructions
gloves
1. SAFETY
1.1.
ELECTRICAL SAFETY
WARNING! It is the user's responsibility to check the following:
Check all electrical equipment and appliances to ensure that they are safe before using. Inspect power supply leads, plugs and
all electrical connections for wear and damage. Sealey recommend that an RCD (Residual Current Device) is used with all electrical
products. You may obtain an RCD by contacting your local Sealey stockist.
If the product is used in the course of business duties, it must be maintained in a safe condition and routinely PAT (Portable
Appliance Test) tested.
Electrical safety information, it is important that the following information is read and understood.
Ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply.
Regularly inspect power supply cables and plugs for wear or damage and check all connections to ensure that they are secure.
Important: Ensure that the voltage rating on the appliance suits the power supply to be used and that the plug is fitted with the
correct fuse - see fuse rating in these instructions.
DO NOT pull or carry the appliance by the power cable.
8
DO NOT pull the plug from the socket by the cable.
8
DO NOT use worn or damaged cables, plugs or connectors. Ensure that any faulty item is repaired or is
8
replaced immediately by a qualified electrician.
This product is fitted with a BS1363/A 13 Amp 3 pin plug.
If the cable or plug is damaged during use, switch off the electricity supply and remove from use.
Ensure that repairs are carried out by a qualified electrician.
Replace a damaged plug with a BS1363/A 13 Amp 3 pin plug. If in doubt contact a qualified electrician.
a) Connect the GREEN/YELLOW earth wire to the earth terminal 'E'.
b) Connect the BROWN live wire to the live terminal 'L'.
c) Connect the BLUE neutral wire to the neutral terminal 'N'.
Ensure that the cable outer sheath extends inside the cable restraint and that the restraint is tight.
Sealey recommend that repairs are carried out by a qualified electrician.
If an extension reel is used it should be fully unwound before connection. A reel with an RCD fitted is preferred since any appliance
plugged into it will be protected. The cable core section is important and should be at least 1.5mm², but to be absolutely sure that the
capacity of the reel is suitable for this product and for others which may be used in the other output sockets, we recommend the use
of 2.5mm² section cable.
1.2.
GENERAL SAFETY
WARNING! THIS HEATER IS FOR PROFESSIONAL USE. IT HAS BEEN CAREFULLY DESIGNED FOR MOBILE AND
TEMPORARY PROFESSIONAL APPLICATIONS.
IT HAS NOT BEEN DESIGNED FOR DOMESTIC USE NOR FOR COMFORT HEATING AND SHOULD NEVER BE USED TO
HEAT CLOSED ROOMS WITHOUT ADEQUATE VENTILATION.
DANGER! Risk of carbon monoxide poisoning. Failure to provide proper ventilation could result in serious illness or death.
Check that the heater is in sound condition and good working order. Take immediate action to repair or replace damaged parts.
9
Use recommended parts only. Unauthorised parts may be dangerous and will invalidate the warranty.
9
Only use diesel or kerosene to fuel this heater, in accordance with instructions contained in this manual.
9
Locate heater on a level and stable surface.
9
WARNING! Only use heater in well ventilated areas. Ensure continuous ventilation is provided to the heater operating area via
windows and doors etc. If people are not required to be present in the heated area, the volume of air to be heated (m³)/heat output
kW) ratio must be at least 10:1 and people must be advised not to remain in the heated area for prolonged periods. If people are
required to be present in the heated area, the volume of air to be heated (m³)/heat output (kW) ratio must be at least 30:1.
Ventilation must be to the outside of the premises in which the heater is to be operated. The total open area (m²) must be at least
0.003 times the total heat output (kW). The volume concentration of oxygen (O
WARNING! DO NOT use the heater near flammable material, liquids, solids, gases or compressed gas cylinders etc.
DO NOT stand or place any object less than 3m from the heater output and keep the heater a minimum of 2m from any
8
walls or objects.
DO NOT use the heater in closed rooms, living areas, basements or below ground level.
8
© Jack Sealey Limited
INDUSTRIAL INFRARED DIESEL HEATER
MODEL NO:
Always unplug
Warning:
before servicing
Hot surfaces
and checking
Original Language Version
IR13, IR16
Do not cover
Keep in dry area
protect from rain
) in the heated room, must always remain above 17%.
²
Use in well
ventilated areas
RECOMMENDED
FUSE RATING: 13AMP
IR13, IR16 Issue 1 27/08/21

Advertisement

loading

Summary of Contents for Sealey IR13

  • Page 1 IR13, IR16 MODEL NO: Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, and properly maintained, give you years of trouble free performance. IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED.
  • Page 2: Specification

    3. SPECIFICATION Model No.s: ............IR13 / IR16 Electrical Plug Type ..........3-Pin BS Fuel Tank ................. 50L Fuel ................Diesel Output (IR13/IR16) ..44,500 (13kW) / 55,000btu/hr (16kW) Heated Area (IR13/IR16) . 11,477ft (325m ) /14,125ft (400m Running Time per Filling (IR13/IR16) ....52hr / 42hr Supply ..............
  • Page 3: Operation

    To run for a set time, select the TIMER function (fig.1.9 ) and use the UP and DOWN arrows (fig.1.7) to set time. The Timer ON indicator (fig.1.10 ) will illuminate. 5. MAINTENANCE IR13, IR16 Issue 1 27/08/21 Original Language Version © Jack Sealey Limited...
  • Page 4: Long Term Storage

    The fuel filter and oil filter should be cleaned at least twice per heating season by rinsing it in clean paraffin or diesel. Contaminated or old fuel could make cleaning necessary immediately. fig.2 Air Inlet Ignition Unit Motor Flame monitor window Pump Flame Sensor Fuel hose Solenoid Valve Fuel Filter IR13, IR16 Issue 1 27/08/21 Original Language Version © Jack Sealey Limited...
  • Page 5: Troubleshooting

    Important: No Liability is accepted for incorrect use of this product. Warranty: Guarantee is 12 months from purchase date, proof of which is required for any claim. Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR 01284 757500 01284 703534 sales@sealey.co.uk...
  • Page 6 The seasonal space heating Energy efficiency in active mode ƞ 100.0 s,on The seasonal space heating energy efficiency ƞ ƞ 91.4 Energy efficiency classes Contact details: Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk, IP32 7AR. www.sealey.co.uk ERP Table 1...
  • Page 7 The seasonal space heating Energy efficiency in active mode ƞ s,on The seasonal space heating energy efficiency ƞ ƞ 91.7 Energy efficiency classes Contact details: Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk, IP32 7AR. www.sealey.co.uk ERP Table 1...

This manual is also suitable for:

Ir16