Lunos eGO Installation Instructions Manual

Lunos eGO Installation Instructions Manual

Decentralized ventilation system with heat recovery
Hide thumbs Also See for eGO:

Advertisement

Quick Links

Installation Instructions
eGO Decentralized Ventilation System with Heat Recovery

Safety instructions

Beware: Any assembly work to the ventilation device may only be carried out after disconnecting all phases of supply voltage. The
ventilation device is fitted with protective insulation according to Protection Class II.
Attention: The electric connection may only be made by authorised qualified personnel and according to the applicable version of
VDE 0100.
Attention: This device may not be operated by children and persons (filter replacement/ cleaning) who are not able to operate the
device safely due to their psychical, sensory or mental abilities or their inexperience or lack of knowledge. Children should be supervised
to ensure that they do not play with the device.
Supply Voltage:
230VAC 50Hz
Device Voltage:
12VDC SELV
Protection Rating:
IP22
Volume Flow:
5 -20 m³/h, 45m³/h exhaust air max
Sound Level:
23 dB - 43 dB
Wiring:
KAT6, KAT5e or KNX cables (For SIPS panel house – KAT 6 ISZH, CAT5e ISZH or KNX ISZH)
Installation Instructions
2/65 Ellice Road, Wairau Valley, Auckland 0629
Ph. 09-443 6996

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the eGO and is the answer not in the manual?

Questions and answers

Summary of Contents for Lunos eGO

  • Page 1 Installation Instructions Installation Instructions eGO Decentralized Ventilation System with Heat Recovery Safety instructions Beware: Any assembly work to the ventilation device may only be carried out after disconnecting all phases of supply voltage. The ventilation device is fitted with protective insulation according to Protection Class II.
  • Page 2 THE HEATING COMPANY 50 mm deep 24 mm 77 mm 50 mm 48 mm Flush Box 18 W Transformer *Note: Flush box should be aligned with timber frame and the screw points must be horizontal. 90 mm UNI-FT - Controller 60 W Transformer NOTE: Can also be wired to the Smart Comfort Controller...
  • Page 3 THE HEATING COMPANY Installation Position: LUNOS eGO unit has two motors operating simultaneously to provide fresh air in and extract moist stale air out. Minimum distances to the wall and surrounding components must be observed to ensure unobstructed air flow...
  • Page 4 THE HEATING COMPANY Assembly: Step 1 - The penetration through external walls - use Ø162 mm hole saw, for 160Ø PVC tube. When installing in timber frame, fix to timber and seal with Proclima grommet (which is supplied) to building wrap or like. Tube to have not more than 3 mm fall to outside.
  • Page 5 (60W transformer). Install 240V power cable to the transformer then run CAT6 cabling to Controller +ve and -ve. Then run CAT6 cable to eGo unit S1 +ve -ve, S2 +ve - ve. Note: Use KAT 6 ISZH, KAT 5e ISZH or KNX ISZH cables for SIPS panel houses.
  • Page 6 THE HEATING COMPANY Step 3 – Cover the connection section, put the filter back in place and close interior cover safely.
  • Page 7 THE HEATING COMPANY Filter Replacement/Cleaning A red LED illuminating permanently when the filter requires replacing/cleaning. Remove internal grille, remove filter, insert new or cleaned filter (the filter can be cleaned with dishwashing detergent) re-attach internal grille. To reset the filter replacement LED, rocker the W1 (left switch) one time within 3 seconds. If it is successful the LEDlights up in RED 3 times to confirm the reset.
  • Page 8 Ventilation Under Tile Heating In-Concrete Heating Infrared Ceiling Heating Panel Heaters Mirror Demisters Controllers Self Levelling Compound Insulate Mat www.theheatingcompany.co.nz 0800HEATING (432 846) 2/65 Ellice Road, Wairau Valley, Auckland 0629 Ph. 09-443 6996...