Indications for safety use
This product is intended for
use by medical professionals or patients who are under medical
supervision.
Caution
: Federal law restricts this device to sale by or on the
order of a practitioner licensed by the law of the State in which
he/she practices to use or order the use of the device.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RevitaPump LX7 and is the answer not in the manual?

Questions and answers

Summary of Contents for Doctor Life RevitaPump LX7

  • Page 1 User Manual Indications for safety use This product is intended for use by medical professionals or patients who are under medical supervision. Caution : Federal law restricts this device to sale by or on the order of a practitioner licensed by the law of the State in which he/she practices to use or order the use of the device.
  • Page 2: Table Of Contents

    Contents 1. Instruction ............Introduction ..........Safety Information 2. Product Description ..............Device ............Accesorries 3. How to use ............... Device ......Cuffs (Leg, arm and centerbody) ............. Cuffs (Pelvis) ......Cuffs size and Extension zipper ............4. Reference ....5.
  • Page 3: Instruction

    1. Instruction | Introduction Introduction Thanks for purchasing our product. This product is an Air Compression Therapy System to improve the blood circulation of the human body. Patient can also purchase or use it personally after receiving doctor’s indications definitely. The operating principle is that the air from the controller will be delivered to the cuff with 4 air chambers and the air pressurizes sequentially the chambers from 1st to 4th.
  • Page 4: Safety Information

    1. Instruction | Safety Information Electrical Safety - Please use a suitable AC cord for each country. (Fire accidents and electric shocks possible) - Stop using the device in case of smelling during using the device. In this case, turn off the electric power and pull out plug from outlet,and then inform it to service center.
  • Page 5 Regarding cuff - Do not use cuffs on undressed body. Use the cuffs with wearing thin under wears. (Cuff's endurance can be weakened due to sweat cosmetics and sebum) - Do not use other tools, except our machines, to blow air into cuffs. prohibition - Do not stain cuffs by oil, benzene, alcohol, gasoline etc.
  • Page 6 Safety for body - Do not use the device in a drunken state. prohibition - Forbid children to use the device. Serious injuries can be occurred when the air blows into cuffs. - Do not use air hose to nose, mouth or ears.(Any injuries possible) - Prohibit to use the device in case of artificial-heart etc.
  • Page 7 Use and Maintenance - Use the device indoors of 0~40℃ (If not, any defects or fire accidents possible) - Do not use or keep the device near to heating equipments or a direct ray of the sun. (Defects, fire accidents, or transformations possible) prohibition - Forbid children to touch.
  • Page 8: Product Description

    2. Product description | Device Operating time touch / Display Compression modes touch / display : Button to set up the operating time : Button to set up the operating mode. Optional care touch button / display Pressure intensity display : Button to select or remove the chamber : Display to indicate the operating wants to be operated.
  • Page 9 Specifications Power AC 230V, 50/60Hz Product weight 2kg (package 6.5kg) Time range 10, 20, 30 min. Product size 260 × 160 ×120mm Pressure range 20~200mmHg ± 20mmHg Power consumption 50VA Clause 5 1. Type of protection against electric shock: Class II equipment. 2.
  • Page 10 2. Product description | Accessories Basic set Single hose Leg cuff (2EA) Double hose (1EA) Foot pad (2EA) One touch basic set One touch single hose One touch Leg cuff (2EA) One touch double hose Foot pad (2EA)
  • Page 11 Optional Accessories Arm cuff One touch Arm cuff A centerbody cuff Extension zipper (Leg or arm, pants) Pelvis cuff Waist cuff one touch waist cuff...
  • Page 12: Device

    3. How to use | Device Special Features 1. Two selectable modes There are two operating modes you can select. (Massage mode, Circulation mode) 2. Optional care mode A user can choose any chamber which the user wants to have the massage or to be skipped for safe treatment on any part with a wound.
  • Page 13: Cuffs (Pelvis)

    4. For arm cuff use Use an attachable part of the arm cuff on a shoulder to be tied up. If not, the cuff slip down during the operating. We recommend using only one cuff if there is no any protector like a nurse or therapist near to a user.
  • Page 14 To set up the operating time The timer is comprised of 10, 20, 30 min. buttons. - Press any time button you want to have the operation for. - It is able to change the time during the operating or pause. To set up the operating mode The compressor has two operating modes.
  • Page 15 To set up the optional care mode Optional care mode can choose any chamber you want to have the massage. It is not only able to set up on each massage or circulation mode, but also able to to set up during the operating. To connect hose plug to air socket - Put a hose plug into the air socket as the picture.
  • Page 16 3. How to use | Cuffs How to use cuffs (arm, leg, centerbody) To use one cuff only - Put a cuff (Leg, arm or waist) on and plug in a single hose to air socket. - Plug in completely for prevent air leakage. (Refer to picture).
  • Page 17 How to use pelvis cuff 1. Wrapping - Please place the center of a pelvis cuff to the center of a hip by being symmetrical on the either side of a pelvis for suitable compression of pelvis. Check the center of a cuff is placed Check it is placed rightly to be symmetrical on the either on the center of hip rightly.
  • Page 18 Cuff size and Using extension zipper Extension cuff (Optional purchase) - Use an extension zipper if the cuff does not fit you. - Zip down completely and put the extension zipper between the cuff and zip up. Leg cuff (L) and extension zipper Leg cuff (XL) and extension zipper 76cm 65cm...
  • Page 19: Reference

    4. Reference Information regarding potential electromagnetic or other interference This equipment has been tested and found to comply with the limits for medical devices in IEC/EN 60601-1-2. These limits are designed to provide reasonable protection against harmful interference in a typical medical installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to other devices in the vicinity.
  • Page 20 WEEE marking This marking shown on the product or its literature, indicates that it should not be disposed with other household wastes at the end of its working life. To prevent possible harm to the environment or human health from uncontrolled waste disposal, please separate this from other types of waste and recycle it responsibly to promote the sustainable reuse of material resources.
  • Page 21 Stop the device during operation ※ Stop the operation of a control and follow one's doctor's indications for the below symptoms. 1) When feeling difficulty of breathing or giddiness 2) When a part of body is felt any so strong compression 3) When feeling so serious pain during using a device 4) When body is paralyzed temporally or felt any itchy 5) When feeling any other strange during using a device...
  • Page 22: Self Check Before Customer Use

    5. Self check before customer use Operating Condition Checking Point - Plugged in correctly into outlet? No electric power - Proper voltage? - Fuse short? Not operating after power on - Plug out and plug in again. - Horizontally placed? Noise in progress - Any material or dust inside the compressor? - Is hose folded?
  • Page 23: Warranty

    WARRANTY Much appreciated on using our device. We, Daesung Maref are doing our best to improve the quality of our products. We will do our best effort to be a good companion of users. ※ In case of followings, we can not repair our device gratuitously even though warranty period : 1.
  • Page 24 2013-01-03 Rev. 2 History & Certificates 2011 President Award 2010 Anvisa in Brazil 2007 Authentication of Merit certificate 2006 Innovation management awards 2006 KOTRA B2B e-Trade awards 2006 KFDA awards by Prime minister 2006 KGMP registration 2004 The 34 precious Technique bronze awards 2004 Korean World class products award 2004...