Instruction Manual Matrix Meter 309497K Used to dispense petroleum-based lubricants and antifreeze only. Part No. 246008 Series D, North America (N. A.) Part No. 249881 Series D, Australia 1500 psi (10.3 MPa, 103 bar) Maximum Working Pressure 600 psi (4.1 MPa, 41.4 bar) Maximum Dynamic Working Pressure (while dispensing) 5 gpm (18.9 lpm) Maximum Flow Rate Important Safety Instructions Read all warnings and instructions in this...
Do not alter or modify equipment. • For professional use only. • Use equipment only for its intended purpose. Call your Graco distributor for information. • Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces. •...
Programming the Meter Programming the Meter Graco recommends that meters be programmed prior 4. The screen indicates a Network and Transceiver ID. to installation. See F . 1. For ease of installation be sure to tag each meter with the corresponding PC meter number from the Matrix PROGRAM MODE software.
Page 5
Programming the Meter 5. The meter displays the appropriate programmed screen and a pop-up window displays on the PC indicating programming is complete. This process is repeated for each meter in the system. The PC software allows a 5 minute period to pro- gram the meter.
Matrix meters See CleanLine Filtration System, Instruction Manual 310652. • All Matrix systems MUST use the Graco Clean- Line System for initial flushing and ongoing oper- ation for all service fluids. See CleanLine Filtration System, Instruction Manual 310652. •...
Page 7
Programming the Meter Mounting Brackets Mounting bracket kit 249440 is available for resting a Matrix meter on a console. See F . 5. ti6733 DESCRIPTION, See F . 4. Fluid shut-off valve Mounting bracket 15B750 is available for resting a Hose Matrix meter on a 16 gallon drum.
Programming the Meter Pressure Relief Procedure Pre-installation Procedure WARNING 1. Relieve the pressure. Follow the Pressure Relief Procedure on page 8. 2. Close the shut-off valve (J). See F . 4. Read warnings, page 3, and follow the Pressure 3. Ground the hose and reel or console. See Ground- Relief Procedure whenever you: ing.
Programming the Meter Installing Nozzle Extension CAUTION Graco recommends using PTFE tape on hose threads 1. Slide the impact guard (40) onto the tube or hose of prior to installing the Matrix meter. PTFE tape should the nozzle extension assembly. See F .
Meter Operation Meter Operation Asleep / Awake Mode Battery Life Indicator Asleep is a battery-saving mode in which the display On the right side of the display is a series of four bars goes blank after two minutes of inactivity during normal located under the word BATT.
Meter Operation Security Modes When the meters were originally programmed by the PIN CODE system administrator, one of the following security ENTER choices was entered: 2122 • System Monitoring • PIN Code • Parts Room Authorization LEFT RIGHT Prior to dispensing, it may be necessary to complete .
Meter Operation Work Orders and Job Numbers When the meters were programmed by the System 1. At the Work Order/Job Number meter screen, Administrator, one of the two Work Order processing select the Enter New option using the up and down methods below was selected.
Page 13
Meter Operation 5. When the numbers are complete, press the right Placing a Meter in the Emergency Mode keypad button until the cursor underlines the Enter The Emergency Code Number must be provided by the option. Press the up arrow on the meter keypad system administrator before performing this procedure.
Meter Operation Dispense Options Preset Dispense Mode The meter dispense options are determined by the sys- Meters programmed in preset mode count down from a tem administrator at the time the meter is programmed. specified value to zero and shut off automatically. The Meter dispense options include: preset value can be increased or decreased from the ini- tial value using the up and down keypad buttons.
Meter Operation Removing and Replacing the Battery 1. Remove the battery by pressing in on both battery lock buttons (E) and pulling the battery (F) out and away from the meter. See F . 20. 2. Place the battery in the battery charger. See Instruction Manual 309502 for details.
Follow the Pressure Relief Procedure, page 8. Be sure all other valves and controls and the pump are operating properly. If using the chart below to trouble- shoot is not successful, contact your Graco distributor for repairs or component replacement. Read warnings, page 3.
Page 17
Troubleshooting Problem Cause Solution Meter does not Meter valve is blocked with debris - Flush the valve with mineral spirits at high pressure and stop dispensing. flow bars DO NOT show on the meter flow. Warning: Do not exceed the maximum working display when the trigger IS NOT actu- pressure of the meter (1500 psi - 103 bar).
Page 18
Troubleshooting Problem Cause Solution Meter has been in E-Prom on meter board has reached Attempt to reprogram the meter. If you see a pop-up service for an the end of its life. screen on the PC that says, “Memory Failure” and/or the extended period of meter screen defaults to the ACTIVATE/ACTIVATE time and begins to...
Calculating the Calibration Factor Calculating the Calibration Factor Use the following tables and formulas to calculate the change to the calibration factor. Example of Calibration Adjustment for Motor Oil (quarts - 368) Dispense into a clean, calibrated, volumetric measuring flask until the meter display indicates 1 quart of fluid has been dispensed.