Page 1
METER MIST Automatic Deodorant Dispensers...
Page 2
Available in 2 Models Meter Mist 3000 Plus Meter Mist 3000 Select 788801 F30001...
Page 3
Meter Mist 3000 Plus & 3000 Select Used where malodors exist or where fresh scents are preferred Covers up to 6000 cubic feet per unit (width x length x height) Can be wall mounted or placed on a flat surface 24/7 dispensing of scents or insecticide Custom control of the spray frequency Require 2 “D”...
Page 4
Meter Mist 3000 Plus Product number 788801...
Page 5
Meter Mist 3000 Plus •Can be set from 5 to 25 minute spray intervals •Can be set to spray: When lights are on (Day) When lights are off (Nite) All the time (24 Hour) •Low Battery indicator light •Refill indicator light •Audible refill indicator can be switched on or off as desired •Reset button turns refill indicators off •Keyless locking cover...
Page 6
Meter Mist 3000 Plus Power indicator light Refill indicator light Spray interval timing dial Reset button Day, nite, 24 hour set switch...
Page 7
Meter Mist 3000 Plus Refill alerts test button 3 way switch Unit on, refill buzzer and light AUDIO-ON Unit on, refill light only QUIET-ON Keyless lock...
Page 8
Meter Mist 3000 Plus Meter Mist can See slide 6 for details nozzle fits here Meter Mist can fits here Batteries (2 “D” cell)
Page 9
Meter Mist 3000 Plus Unit comes out of the box set for; 15 minute spray intervals 24 hour setting...
Page 10
Meter Mist 3000 Plus To open unit depress keyless lock and swing front cover open Insert 2 “D” cell batteries (included) into battery chamber Be sure to follow battery diagram on the rear of the chamber...
Page 11
Meter Mist 3000 Plus 3) Using a small flat blade screwdriver, spray intervals can be changed by turning arrow on BLUE timer button to desired interval Can be set from 5 to 25 minute intervals 4) Set to Day, Night, or 24 Hour by sliding switch Day-unit sprays when lights are on, Nite-unit sprays when lights are off,...
Page 12
Meter Mist 3000 Plus Insert product can into dispenser If replacing product push the RED reset button BEFORE 7) Turn unit to inserting can QUIET ON or Close cover AUDIO-ON AUDIO ON QUIET-ON as desired **BE CAREFUL, WHEN UNIT IS TURNED ON IT WILL SPRAY! KEEP FACE AWAY FROM FRONT OF UNIT...
Page 13
Meter Mist 3000 Select Product number F30001...
Page 14
Meter Mist 3000 Select •Can be set to 7(HI), 14(ME), or 28(LO) minute spray intervals LO, ME, HI refer to intensity of odor problem •Can be set to spray: 12 hours per day 24 hours per day •May be programmed to turn off up to 2 days per week •LCD display •Battery strength indicator •Days to refill indicator...
Page 15
Meter Mist 3000 Select LCD Information window Audible tone on-off button Reset Button On-Off button Mode Button* Adjust Button* Enter Button* *MODE, ADJUST, and ENTER buttons are used for custom programming of unit...
Page 16
Meter Mist 3000 Select Keyless lock Unit cover...
Page 17
Meter Mist 3000 Select Meter Mist can nozzle fits here LCD Information window See slide 5 for details Meter Mist can fits here Batteries (2 “D” cell)
Page 18
Meter Mist 3000 Select Battery life indicator Information Number of days until Window product needs to be refilled...
Page 19
Meter Mist 3000 Select Unit comes out of the box set for; 30 day refill (ME-14 minute spray intervals) 24 hours, 7 days a week...
Page 20
Meter Mist 3000 Select 1) To open unit press keyless lock and swing front cover Insert 2 “D” cell open batteries (included) into battery chamber Be sure to follow battery diagram on the rear of the chamber...
Page 21
Meter Mist 3000 Select LCD DISPLAY WINDOW 3) Press on-off button to turn unit LCD window will show battery and 4) Press tone 30 day refill button to turn audible refill alert on or off LCD will display alert symbol **TO AVOID ACCIDENTALLY BEING SPRAYED, NEVER STAND DIRECTLY IN FRONT OF UNIT...
Page 22
Meter Mist 3000 Select Insert product can into dispenser If replacing product push Swing cover the RED reset button BEFORE closed inserting can If custom programming is desired refer to instructions on following slides...
Page 23
Meter Mist 3000 Select Custom Programming The unit will cycle through all the custom settings each time you enter the programming mode, be sure to press “ENTER” to exit when finished programming “ENTER” BUTTON...
Page 24
Meter Mist 3000 Select Setting spray intervals Press the “MODE” button once Press the “ADJUST” button until desired interval is displayed HI (7 minute intervals) ME (14 minute intervals) LO (28 minute intervals) Press the “ENTER” button to save your setting...
Page 25
Meter Mist 3000 Select Actual time setting Press the “MODE” button a second time Press the “ADJUST” button until desired time is displayed Advances by 10 minute intervals Press and hold the adjust button to fast forward time Watch for AM / PM indicator when setting ...
Page 26
Meter Mist 3000 Select If 12 hour setting is selected 12 or 24 hour operation Next screen will Press the “MODE” display the time button a third time Set this to the time Press the “ADJUST” you want the unit to button until desired START operating setting is displayed...
Page 27
Meter Mist 3000 Select Actual day setting (unit can be turned off up to 2 days a week) Press the “MODE” button a fourth time Press the “ADJUST” button until current day is displayed Press the “ENTER” button to save ...
3000 Plus & 3000 Select Installation Instructions Please view the INSTALLATION VIDEO located on the main page of the Zep Equipment web site www.zepequipment.com to learn how to properly mount your Meter Mist units to the surface you are working with...
Page 29
Meter Mist 3000 Plus & 3000 Select The mounting holes for both units are identical Mounting Mounting Holes Holes 3000 Select 3000 Plus...
Page 30
Meter Mist 3000 Plus & 3000 Select Installation Instructions Proper selection of placement for the unit Mount unit at least 7 feet high to avoid spraying in face Don’t mount directly above a toilet or urinal Make sure unit isn’t directly facing anyone sitting in office Always use ALL the mounting holes Always use the correct mounting hardware View Installation Video to see what hardware is needed for the surface...
Need help?
Do you have a question about the METER MIST 3000 Plus and is the answer not in the manual?