Louver direction

NOTE
• To improve the cooling/heating performance, change
the louver angle for each operation.
• This function is not available for duct type units.
The characteristics of air: cool air falls, and warm
air rises.
CAUTION
Point the louver horizontally during cooling
If pointing downward for cooling, dew may form on the
surface of the air discharge or louver and may drip.
NOTE
• If pointing horizontally for cooling, dew may form on
the surface of the cabinet or louver and may drip.
• If pointing horizontally for heating, the room
temperature may be uneven.
• Do not handle the louver manually.
Doing so may cause a failure.
Use the SWING/FIX button on the remote control to
adjust the angle.
19-EN
 4-way Cassette type,
Compact 4-way Cassette
type, Ceiling type
◆ To set the louver direction
1
Push the
button while running.
SWING/FIX
The louver direction changes with each push of
the button.
▼ For heating
Point the louver downward.
If not pointing downward, hot
air may not reach the floor.
Initial setting
▼ For cooling
Point the louver horizontally.
If pointing downward, dew
may form on the surface of
the air discharge port and
may drip.
Initial setting
▼ For fan
Select a wind direction.
Initial setting
◆ To start swinging
1
Push the
SWING/FIX
button repeatedly to set the
louver direction to the lowest position, then
push
SWING/FIX
again.
The SWING
indicator appears and the louver
begins to swing.
▼ In all operations
Repeat
◆ To stop swinging
1
Push the
SWING/FIX
button at the desired
position while the louver is swinging.
• Push the
SWING/FIX
button repeatedly to change
the louver position again.
SWING/FIX
* However, even if the
button is pushed
while the louver is swinging, one of the
indications below may sometimes appear and
may not set the louver to the highest position.
▼ Indications when swinging is stopped
FAN/HEAT
COOL/DRY
In this case, push the
SWING/FIX
button again after 2
seconds.
• In the Cool/Dry operation, the louver does not
stop as it directs downward. If stopping the
louver as it directs downward during the swing
operation, it stops after moving to the third
position from the highest position.
▼ Indications when swinging is stopped
FAN/HEAT
COOL/DRY
operation
operation
◆ Unit select
• When two or more indoor units are controlled with
one remote control, the louver direction can be set
for each indoor unit by selecting them individually.
• To set the louver direction individually, push the
UNIT LOUVER
button (left side of the button) to display an
indoor unit number in the control group. Then set the
louver direction of the displayed indoor unit.
• When no indoor unit number appears, all indoor units
in the control group can be controlled
simultaneously.
• Each time the
UNIT LOUVER
(left side of the button) is
pushed, the indication changes as follows:
No
Unit No.
Unit No.
display
1-1
Unit No.
Unit No.
1-4
1-3
– 10 –
 4-way Cassette type only
◆ To set the louvers individually
1
UNIT LOUVER
button (left side of the
Push the
button) during running to select a unit.
The unit number changes each time the button is
pushed.
Unit No.
Unit No.
1-1
1-2
No
Unit No.
display
1-4
• When no unit number is displayed, all units are
selected.
2
Push the
UNIT LOUVER
button (right side of the
button) to select a louver.
Each time the button is pushed, the indicator on
the left of the remote control changes as follows:
* When no louver number appears, all 4 louvers
are selected.
Louver No.
Electrical control box
03
Refrigerant
pipe
04
Drain pipe
1-2
01
Unit No.
1-3
No
display
02
EN