Atmos D15P Instruction Manual

Atmos D15P Instruction Manual

Hide thumbs Also See for D15P:
Table of Contents

Advertisement

Quick Links

Instruction manual - GB II.
Instruction
manual
www.atmos.cz

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the D15P and is the answer not in the manual?

Questions and answers

Summary of Contents for Atmos D15P

  • Page 1 Instruction manual - GB II. Instruction manual www.atmos.cz...
  • Page 2: Table Of Contents

    11. Connecting boilers to the electric network 12. Wiring diagram of electromechanical regulation with an extraction ventilator, type UCJ 4C52 (D15P, D20P) 13. New wiring diagram of electromech. regul. with an extraction ventilator, type UCJ 4C52 (D15P, D20P), valid from 12/2007 14.
  • Page 3 In non-compliance with these principles, the drum’s and the heatproof shaped pieces’ service life may dramatically decrease due to low-temperature corrosion. The boiler drum may corrode in as little time as 2 years. www.atmos.cz 4-GB...
  • Page 4: Intended Use

    Instruction manual - GB II. 1. Intended use The hot water boilers ATMOS D15P, D20P, D30P and D45P are designed for convenient heating in residential houses, weekend house and other similar buildings by wood pellets 6 – 8 mm diameter.
  • Page 5: Control Panel Appearance

    ČERPADLO / PUMP KOTLOVÝ / OPERATING 1. Thermometer 6. Extraction ventilator switch (except for the 2. Main switch D15P type) 3. Control thermostat (for boiler) 7. Fuse 4. Pump thermostat 8. Area for electronic regulation of the heating 5. Safety thermostat...
  • Page 6: Technical Data

    Instruction manual - GB II. 3. Technical data ATMOS boiler type D15P D20P D30P D45P Boiler output 4,5-15 6,5-22 8,9-29,8 13,5-45 Heating surface Fuel shaft volume Feeding hole dimensions 270x450 270x450 270x450 270x450 Specified chimney draught Max.operating water-pressure Boiler weight...
  • Page 7: Boiler Drawings Key

    26. Fuse 9. Extraction ventilator 27. Extraction ventilator switch (except for the 10. Output regulator - Honeywell FR 124 D15P type) 11. Door filling - Sibral 28. Grill 12. Door sealing 18 x 18 mm K – the flue-gas duct neck 13.
  • Page 8: Drawings Of Boilers

    Instruction manual - GB II. Drawings of boilers Cut away views - type D15P Cut away vies – types D20P, D30P, D45P www.atmos.cz GB-9...
  • Page 9: Cut Away View - Type D15P Cut Away View - Type D45P

    Instruction manual - GB II. Cut away view - type D15P Cut away view – type D45P Boiler without an extraction ventilator Boiler with an extraction ventilator Extraction ventilator schematics – boiler types D20P, D30P, D45P CAUTION – The extraction ventilator is supplied disassembled. Place it over the rear flue- gas duct, tighten everything well, connect into a socket and test for its smooth operation.
  • Page 10: Supplied Boiler Accessories

    This device must be installed in compliance with the supplied installation instructions. When installing the device, we follow the installation manual delivered with the device. www.atmos.cz GB-11...
  • Page 11: Fuel

    Good quality pellets are such that do not disintegrate into sawdust and are made from soft barkless wood (so called white pellets). 6. Boiler bases Boiler type (mm) D15P, D20P D30P D45P 1000 We recommend providing a concrete (metal) base under the boiler.
  • Page 12: Chimney

    3 of the Czech standard ČSN 061008/97. These are appro- priate for mobile installations, wooden cottages etc. Waste gas thermometer Cleaning aperture Throttle valve (draught limiter) In case of excessive chimney draught, install a throt- tle valve (3) or draught limiter. www.atmos.cz GB-13...
  • Page 13: Fire Prevention During Installation And Use Of Heating Appliances

    PVC etc.) the boilers must be put out of operation long enough before the risk occurrence. No items from flammable materials may be placed on the boilers or near them into a distance lower than the specified safe distance. www.atmos.cz 14-GB...
  • Page 14: Connecting Boilers To The Electric Network

    12. Wiring diagram of electromechanical regulation with an extraction ventilator, type UCJ 4C52 (D15P, D20P) The A and B connectors are used for the power supply of the heating-system electronic reg- ulation. The electronic regulation may be fitted in the control panel of certain boiler types.
  • Page 15: New Wiring Diagram Of Electromech. Regul. With An Extraction Ventilator, Type Ucj 4C52 (D15P, D20P), Valid From 12/2007

    Instruction manual - GB II. 13. New wiring diagram of electromech. regul. with an extraction ventilator, type UCJ 4C52 (D15P, D20P), valid from 12/2007       HLvyp HNvyp SNvyp SLvyp     FUSE 6,3 A SICHERUNG 6.3 A...
  • Page 16: Wiring Diagram Of Electromech. Regul. With An Extraction Ventilator, Type Ucj 4C52 (D30P, D45P)

    - Floor heating – Systems and components – Designing ČSN EN 442-2 - Heaters – Testing and test analysis CAUTION – the boiler must be installed in compliance with a design prepared in advance. Installation may only be carried out by persons trained by the manufacturer. www.atmos.cz GB-17...
  • Page 17: Choice And Connection Method Of Control And Heating Elements

    When installing the boiler, position the rear section 10 mm higher (prop it up) in order to facilitate circulating and air-bleeding. For the heating system regulation we recommend regulation elements provided by the following companies: a) ATMOS ACD 01 tel.: +420 326 701 404 b) KOMEXTHERM, Praha tel.: +420 235 313 284 c) KTR, Uherský...
  • Page 18: Boiler Corrosion Protection

    ����� ������ ������ ���� ������ ������ ��������� ���� ����� ������ ��� � ��������� ��� ��� ������ ��� ��� ����� ������ ����� �� � ���� ����� ����� ���������� ���� ������� ����� ����������� ��������� ���� ������ ����� ����� �������� �� www.atmos.cz GB-19...
  • Page 19: Specified Boiler Connection With An Equalizing Tank

    �������� �� Pipeline diameters if connected with accumulation tanks Boiler type and output section A section B in copper in steel in copper in steel D15P, D20P 28x1 25 (1”) 28x1 25 (1”) D30P 35x1,5 32 (5/4”) 28x1 25 (1”)
  • Page 20: Specified Boiler Connection With Laddomat

    If need be, a thermoregulatory valve set to a higher temperature (E.g. 72°C) may be used. Recommended size of the thermoregulatory valve TV 60°C. For boilers: D15P, D20P ................... DN 25 D30P ....................DN32 D45P ....................DN40 www.atmos.cz GB-21...
  • Page 21: Connection Of Overheat Protecting Cooling Loop With A Safety Valve Honeywell Ts 130 - 3/4 A Or Watts Sts20

    25. Operating instructions Preparing boilers for operation Before putting boilers into operation, it is necessary to ensure that the system has been filled with wa- www.atmos.cz 22-GB...
  • Page 22: Boiler Adjustments Before Burning Pellets

    Check that the burner is well drawn towards the boiler through its gasket and the limit switch position-stop is in its place (with ATMOS IWABO and ERATO burners). Also check the tube between the burner and conveyor so that it is stretched and at a sufficient angle to ensure that the pellets can drop without difficulty into the burner.
  • Page 23: Placing The Shaped Pieces Into The Combustion Area (For D15P And D20P Types)

    flame burns out completely and it also protects the boiler parts situated opposite the burner against overheating and damage. Connecting the burner (for D15P and D 20P types) - ATMOS (IWABO or ERATO) pellet burner 3 – Two M8 screws –...
  • Page 24: Connecting The Burner (For D30P And D 45P Types)

    Instruction manual - GB II. Connecting the burner (for D30P and D 45P types) - ATMOS A50 pellet burner – sealing cord 18x32 - large - burner gasket - four M10x45 mm screws - burner connection plate - four M8x10 mm (12mm) screws...
  • Page 25: Boiler Room With A Built-In Pellet Storage

    (P3 potentiometer) for the complete combustion of pellets. The whole cycle keeps repeating. To set parameters of P1 to P4, it is necessary to remove the covering sheet metal, with a visor, attached www.atmos.cz 26-GB...
  • Page 26 E.g. The green diode flashes 3 times followed by 6 flashes of the yellow diode – this means that the fuel burn-off time is set in a way that the burner ventilator keeps operating for 210 seconds after the photocell detects no more light. www.atmos.cz GB-27...
  • Page 27 Recommended (manufacturer’s) setting SW1 - “ON” SW2 – “ON” CAUTION – carry out the commissioning and setting of the ATMOS ERATO or ATMOS A50 burners in compliance with their separate manuals that are supplied with the burners. www.atmos.cz...
  • Page 28: Draught Regulator - Honeywell Braukmann Fr124 - Assembly Instructions

    (only providing the setscrew gap). It is always necessary to fine-tune the specified operating temperature (80 - 90°C) utilising the mixing valves behind the boiler either manually or by electronic regulation with electric actuator. www.atmos.cz GB-29...
  • Page 29: Boiler Cleaning And Ash Removal

    The user must not tamper with the boiler construction or its electrical installation. The boiler must be well cleaned and in time ensuring that all ducts are always obstacle-free. Loading door and ash-pan door must always be well closed. www.atmos.cz 30-GB...
  • Page 30: Possible Failures And Troubleshooting

    - clean the ventilator including the ducting from tar and sedi- Ventilator does not turn ments - defective capacitor - replace - defective motor - replace - bad contact in plug of motor - check - measure cable lead www.atmos.cz GB-31...
  • Page 31: Spares

    Fine-tune the position of the wheel that engages the lock’s cam. This is the only procedure that can ensure good door seal! www.atmos.cz 32-GB...