Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions and
properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS AND
CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY
CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. PLEASE KEEP INSTRUCTIONS SAFE FOR FUTURE USE.
1. SAFETY INSTRUCTIONS
Familiarise yourself with the application and limitations of the compressor.
Ensure that the compressor is in good order and condition before use. If in any doubt do not use the unit and contact a service agent.
 WARNING! Compressor must only be serviced by an authorised agent. DO NOT tamper with, or attempt to adjust the pressure
switch or the safety valve.
Before moving or maintaining the compressor ensure that the air tank pressure has been vented.
Only use recommended attachments and parts. To use unapproved items may be dangerous and will invalidate your warranty.
Read the instructions for any accessory used with the compressor. Ensure that the safe working pressure of any air appliance used,
exceeds the output pressure of the compressor. If using a spray gun, check that the area selected for spraying is provided with an air
change system or adequate ventilation.
Ensure that the air supply valve is turned off before disconnecting the air supply hose.
To move the compressor use the front roll bar. Lift the compressor so that the front legs have enough clearance for manoeuvring but
maintain the centre of gravity in front of the wheels. DO NOT attempt to lift or move the compressor by any other means.
Use the compressor in a well ventilated area and ensure it is placed on a firm surface. Remember that the compressor engine produces
potentially harmful exhaust fumes.
Keep tools and other items away from the compressor when it is in use, and keep area clean and clear of unnecessary items.
Ensure that the air hose is not tangled, twisted or pinched.
Keep children and unauthorised persons away from the work area.
DO NOT dis-assemble the compressor for any reason. The unit must be checked by qualified personnel only.
DO NOT operate the compressor within the vicinity of flammable liquids, gases or solids.
DO NOT touch compressor cylinder, cylinder head or pipe from head to tank as these may be hot and will remain so for some time after
shutdown.
DO NOT attempt to move the compressor by pulling the air tool hose.
DO NOT use the compressor for a task for which it is not designed.
DO NOT deface the certification plate attached to the end of the compressor tank.
DANGER! DO NOT direct the output jet of air towards people or animals.
DO NOT operate the compressor without an air filter.
DO NOT allow anyone to operate the compressor unless they have received full instructions.
For safety instructions relative to the maintenance and use of the petrol engine refer to the engine instruction manual.
DO NOT check the ignition system by removing the spark plug or spark plug lead. Use specific tester or contact service agent.
WARNING! DO NOT touch the spark plug or plug lead whilst the engine is running - severe, potentially fatal, electric shock may
result.
Ensure that engine fuel is stored in an approved container. For long term storage ensure that the fuel tank is drained and that the
compressor is adequately protected.
DO NOT smoke or have any naked flames nearby whilst re-fuelling.
DO NOT leave the compressor operating unattended.
DO NOT remove the fuel cap whilst the engine is running.
DO NOT refuel the engine whilst it is running. Stop the engine and allow it to cool for two minutes before attempting to refuel.
DO NOT refuel in a closed or poorly ventilated environment as there is a danger of explosion or fire. Refuel outdoors.
DO NOT operate the compressor if there is a fuel leak. Move the unit to a safe area, where
there is no risk of ignition, until the leak has been rectified and the machine is dry.
DO NOT start the engine if there are any flammable materials near the exhaust system or
in the path of the exhaust gases.
DO NOT block the engine ventilation grills.
DO NOT cover the compressor or restrict air flow around the machine whilst it is operating.
WARNING! The air tank is a pressure vessel and the following safety measures apply:
DO NOT tamper with the safety valve and DO NOT modify or alter the tank in any way
and DO NOT strap anything to the tank.
DO NOT subject the tank to impacts, vibration or to heat and DO NOT allow contact
with abrasive or corrosive materials.
DO drain condensation from tank daily and inspect inside walls for corrosion every
12 months.
The tank shell must not fall below the certified thickness at any point.
When not in use, store the compressor carefully in a safe, dry, childproof location.
InSTRUcTIOnS FOR:
PETROL ENGINE COMPRESSOR
MOdEL no:
Original Language Version
SA4050/55
SA4050/55
Issue: 3 - 06/10/10

Advertisement

loading

Summary of Contents for Sealey SA4050

  • Page 1 SA4050/55 MOdEL no: Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions and properly maintained, give you years of trouble free performance. IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS AND CAUTIONS.
  • Page 2 2. INTRODUCTION & SPECIFICATION The SA4050/55 compressor has a twin cylinder pump powered by a 5.5hp petrol engine and is capable of supplying air at up to 8 bar from a 50 litre tank. In addition to pneumatic tools, the compressor may be connected to accessories suitable for blowing, washing and spraying.
  • Page 3 Inspect pressure tank inside and out for damage or corrosion. fig. 7 fig. 8 fig. 9 ALIGNMENT Original Language Version SA4050/55 Issue: 3 - 06/10/10...
  • Page 4 3 Monthly 500 hrs. 1000 hrs. temperatures ranging from +5°c to +25°c. Operations • drain condensation SEALEY cPO or equivalent SAE 40 compressor oil. • check oil level Room temperature below +5°c: SAE 20 compressor oil. • clean intake filter •...

This manual is also suitable for:

Sa4055