Advertisement

INSTALLATION GUIDE
1
DESCRIPTION
Oxilife is a water treatment system and a controller for
swimming pools.This water treatment combines electrolysis of
low salinity with hydrolysis.
With the electrolysis of low salinity we produce liquid chlorine
from water which is very slightly salted (from 1,5 to 2,5 g salt
per liter). The hydrolysis produces disinfectants such as oxygen,
peroxide, hydroxyls and ozone. All these oxidants combat and
eliminate organic matter and pathogenic agents present in the
water. The used chlorine reconverts into salt, and the oxidants of
the hydrolysis reconvert into water on its way back to the pool.
Oxilife controls centrally all the components of your pool,
ensuring an efficient interaction.
Electrical connections of the electronic box
Cover
FL1
Chlorine probe
detector (rotameter)
Conductivity probe
Temperature probe
pH
AUX 1
pH Control
Base (pump)*
* An "Installer Menu" does exist for advanced functions. If you are an authorized installer, please ask your provider for the installers/service manual.
Cell
1
Low salinity electrolysis cell
2
RCA flow detector
3
Cell connector
4
Cell housing
5
Flow/gas detector (internal)
Optional automatic controls
pH control
redoX control
Metering and control
Metering and control of
of the pH of the water.
the redoX as check value
of the free chlorine.
110-230 V
DRY CONTACT
max. 3.15 A
N
L
A1 A2
14
11
12
AUX 2
FILTER PUMP
redoX / free chlorine
Filtration control
ppm´s (pump)*
4
1
5
2
3
Free chlorine control
Metering and control in
ppm of the free chlorine
of the water.
!
NEW
from
MODEL
1,5g
2015
FAN
SALT/L
LESS
Electronic box
1
2
3
Low salinity
1
electrolysis
RCA flow detector
2
3
Main connection 230 V
4
ON/OFF switch
redoX
Free
Chlorine
LIGHT
Lighting control
Conductivity
Temperature
Metering and control of
Temperature probe
the conductivity of the
0 - 100° C necessary
water in Msiemens.
to activate the filtration
modes: heating /
intelligent / smart.
PORTABLE
WORLDWIDE
WIFI and
COLOR
REMOTE
DISPLAY
MODBUS
CONTROL
(TFT)
UPGRADE
SELF
SEA
POSSIBLE
CLEAN
WATER
4
5
6
110-230 V
Fuse for device and cell 3.15 A
5
6
Fuse relays 3.15 A
Device control SLAVE
Digital inputs / outputs
Connection
WIFI / RS module
Connection display
pH
AUX 3
AUX 4
Heating control*
Flow detector
Mechanic security flow
switch. Stops the low
salinity electrolysis if
there is no water flow.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the oxilife and is the answer not in the manual?

Questions and answers

Summary of Contents for sugar-valley oxilife

  • Page 1 CLEAN WATER DESCRIPTION Electronic box Oxilife is a water treatment system and a controller for swimming pools.This water treatment combines electrolysis of low salinity with hydrolysis. With the electrolysis of low salinity we produce liquid chlorine from water which is very slightly salted (from 1,5 to 2,5 g salt per liter).
  • Page 2: System Installation

    Let the circulation pump run during the first 24 hours. In case the water is supplied from a well: Shock chlorination with trichloroisocyanuric acid Oxilife system may operate while the salt is dissolving and will operate without problems with (2 kg / 50 m of water).
  • Page 3 4.1 Hydrolysis 1.1 Hydrolysis: 1.2 Level: Desired 1.3 Cover: Connection of 1.4 Boost: Continuous During the Programming of low salinity production of automatic cover. filtration during 24 hours boost period the electrolysis functions. chlorine (%). Reduction of chlorine at maximum intensity. redoX control can production in percent, when Automatic return to...
  • Page 4 4.3 Filtration (continuation) Clima OFF: The heating only works within the set filtration periods. maximum of 24 hours). The device divides the selected “minimum filtration time” Clima ON: Keeps the filtration working when the filtration period is finished if the in 12 fragments which start up every 2 hours.
  • Page 5: Maintenance

    The parameters or setpoints are the minimum/maximum accepted redoX levels before the titanium cell is connected/disconnected. Adjusting the ideal redoX level (setpoint) is the last step in the Oxilife start up sequence. To find the optimum redoX levels for your pool follow these steps: Connect the pool filtration system (the salt in the pool must be adequately dissolved).
  • Page 6: Troubleshooting

    TROUBLESHOOTING Blank display Excess of chlorine in the water Check if ON/OFF switch is illuminated. Lower low salinity electrolysis cell intensity. Check the connection wire between display and motherboard. If your system includes automatic redoX control, check redoX setpoint. Check fuse of the device 3.15 A – it could have tripped due to overload. Check redoX probe and calibrate it if necessary.