Page 1
INSTRUCTION FOR INSTALLATION AND USE The pictures show in this handbook need not always correspond to the particular embodiment; their purpose of to assist better understanding of the textual instruction. The manufacturer and the supplier reserve the right for product changes without the obligation to update this Instruction for Installation and Use.
Safety Information Before fi rst use of your sauna please read carefully all the instructions includ- ed in this hand book and observe them. Installation and use of this electrical equipment requires permanent compli- ance with the related basic safety measures. Use a power socket for this ap- pliance powering installed pursuant to applicable technical standards and provided with a circuit breaker with the corresponding current value and charac- teristics.
Page 3
the case of pregnant women. Overheating increases temperature inside your body, therefore high sauna temperature setting is not recommended. Use of alcohol, narcotics or certain drugs before or during use of the sauna may lead to loss of conscience. Never fall asleep inside a working sauna. Do not use steam cleaners, pressure cleaners or water sprays for cleaning your sauna.
Page 4
When not tou use sauna It is recommended not to use sauna in 24 hours from exposure to UV ra- diation from artifi cial sources or sun bath. Prescription drugs: ask your doctor or pharmacist about potential inter- action of the sauna with your medication. Some drugs, such as diuretics, antihistamines, beta blockers and barbiturates may negatively aff ect the natu- ral heat regulating property of human body.
Page 5
adrenalin insuffi ciency (for example in the case of Addison disease). People suff ering from haemophilia or bleeding episodes should also avoid sauna use for heat widens the blood vessels. Sauna is further not recommended to people suff ering from fever or sen- sitive to heat.
PŘEDSTAVENÍ VÝROBKU Product Introduction rvená sauna (infrasauna) je tvořena dřevěnou kabinou, infračervenými topnými keramic Infra red sauna (infrasauna) consists of a wooden cabin, ceramic or carbon karbonovými tělesy a ovládacím systémem. Dřevěná kabina obsahuje SPODNÍ DE infra red heaters and a control system. The wooden cabin comprises a BOT- DESKU, LEVOU DESKU, PRAVOU DESKU, PŘEDNÍ...
Page 7
Control Cabinet The control cabinet is the control cen- tre of the sauna. The control cabinet is pre-installed in the TOP PLATE and only needs cable end connections. PŘEZKA PŘEZKA Buckle Standardní přezky pro spojení tělesa sauny Standardní přezky pro spojení tělesa sauny Standard buckles for the sauna body connection MONTÁŽNÍ...
Page 8
Assembly Instructions Read the instruction for use carefully before assembly. The sauna assembly requires two adult persons. Read all instructions carefully before starting the assembly and remem- Note: ber to observe all applicable basic safety measures. Find the right place for the sauna installation first. Sauna should be placed in a tempered space with low air humidity.
Page 9
MONTÁ Note: The invisible wooden parts of the sauna may contain minor damage from the manufacture (indentations, scratches etc.) not affecting the sauna function or its outer appearance. Hair tears may develop in the sauna wood in the course of use. This is not product damage but natural property of the wood.
Page 10
Assembly Instructions D. Nainstalujte LAVICI a proveďte ka propojení D. Na DESKU S TOPNÝMI TĚLESY PRO LAVIC D. Na D. Install the BENCH and the CABLE CON- do příslušné vertikální drážky v ZADNÍ DE DESKU NECTIONS Mřížka topného tělesa směřuje ven (smě do přís DESKU Insert the Plate with the bench heating...
Page 11
F. Install the HANDLE Install the two-piece handle in the door. F. Nainstalujte MADLO G. Install the TOP PLATE The side with the CONTROL CABINET is the top side of Do DVEŘÍ namontujte dvoudílné MADLO. F. Nainstalujte MADLO the TOP PLATE. Z vnitřní...
Page 12
H. Zapojení zástrček na HORNÍ DESCE Pospojujte všechny kabelové spojky. V případě Assembly Instructions vodičů. Poznámka: Nezapojujte napájecí šňůru z HOR H. Connecting TOP PLATE plugs H. Zapojení zástrček na HORNÍ DESCE Pospojujte všechny kabelové spojky. V případě shodných kone Connect all cables.
Page 13
Sauna Control and Operation Before switching the sauna on check and test connections of the CON- Note: TROL BOX, the HEATERS, the MP3 PLAYER/RADIO, the TEMPERATURE SEN- SOR etc. and make sure the electrical power parameters and frequency cor- respond to the value required for your sauna. Make sure you have sufficient power input available and then switch on the sauna.
Page 14
Sauna Control and Operation ture and the temperature sensor location may cause a difference between the actually measured temperature inside the sauna and the heating temperature set on the control panel amounting up to 5 °C. Heating Start/Stop With the system on the POWER control below the display is illuminated and if the temperature inside the sauna is lower than the setpoint the HEAT control below the display will illuminate and the heating units will start work- ing.
Time + / -: nastavení doby topení Control Panel Functions Switching between temperature units °C/°F: Temperature adjustment up/down Temperature +/-: Reading lamp on/off Inside light: Outside lighting on/off Outside light: Power On/Off Power: Heating time setting Time +/-: On the left you will see the temperature value (with °C or °F indication next to it), and on the right there is the heating time in minutes.
Page 16
OVLÁDÁNÍ MP3/RÁDIA S DÁLK MP3/RADIO REMOTE CONTROL A. Description of MP3/Radio Con- trol on/off selector playing MODE source (radio, USB/SD card, AUX or Bluetooth). If USB/SD is not in the MODE button is used for ending of calls via Bluetooth. radio frequency BAND/AMS switch button / automatic saving.
Page 17
B. Popis dálkového ovladače B. Remote control description 1: Vypnutí / zapnutí Off/on 2: MODE MODE 3: MUTE MUTE 4: BAND 5: VOL+: zvýšení hlasitosti BAND 6: AMS VOL+: up key : vyhledávání stanice vzad předchozí skladba backward station search / pre- 8: SEL vious composition : vyhledávání...
Page 18
WHAT IS INFRA RED RADIATION (IR) Infra red radiation is electromagnetic wave between the visible light and micro- wave wavelengths. This radiation is similar to sun rays heating our skin by direct IR radiation even in cold days. 95 % of the carbon fi bre energy is transformed to long-wave IR waves with wavelength between 5 and 17 microns.
Page 19
HOW TO USE INFRASAUNA You can best use the potential of the infra red therapy when setting the temperature to the top value. Thus your body will use the full potential of the infra red radiation during your stay in the sauna cabin. If you set the temperature to a lower value the heaters will switch off and on to keep the set temperature.
Page 20
WHAT IS INFRA RED RADIATION (IR) pores will be open and the soap might obstruct them. It is important to replenish liquids sweated out of your body during your sauna stay. Fresh water is the ideal drink which will not return to the body the calories burnt by sweating.
Page 21
BENEFITS OF SAUNA The benefi ts of infra red therapy have been studied for several decades in Ja- pan, Europe and since recently also in the United States. The following benefi - cial eff ects have been observed in people using infra red sauna regularly: blood pressure reduction joint stiff ness reduction weight loss...
IMPORTANT WARNING Infra red radiation emitted by your infra red sauna is recognised as a source with a wide spectrum of potential positive therapeutic eff ects, as documented by research studies performed in diff erent parts of the world. These benefi ts are presented here for reference only and do not mean to say that infra red sauna is a source of treatment of any disease.
Page 23
OXYGEN IONISER (or negative ion generator) is an instrument using high voltage to ionise Ioniser (electrically charge) air molecules. Negative ions (anions) are particles with one or more received electrons. are colourless, odourless and the negatively charged electrons in orbit Anions permits them draw various micro particles from the air.
TECHNICAL SPECIFICATIONS 12 V DC Power input Output < 5W Anion generation 100x104 pc/cm3 Ozone generation ≥ 5mg/hr Do not touch the HV cable ends with bare hands or metal objects. Warning! Otherwise, electric shock may occur.
Page 25
ERROR LOCALISATION Problem Solution Sauna does not Check correct connection work, the con- to power trol panel does not Check the switch on the control box (top display anything plate) Check connection of the current fuse on the control box (if disconnected press it down) Heaters do not Connect the sauna, switch it on and check heat...
Page 26
TECHNICAL SPECIFICATIONS Problem Solution The display on Replace the control panel control panel only shows part of the text MP3/radio does Check connection of the power cable of the not work MP3/radio unit, and aerial connection Remote control Check the remote control battery for correct MP3/radio placement and for discharge does not work...
Doporučujeme poznamenat si do níže uvedených polí modelové číslo a výrobní číslo výrobku (viz spodní část vnější strany boční desky). SERVICE AND SPARE PARTS Modelové číslo In case you need advice, service support or a spare part, contact your dealer. Modelové...
Page 28
Instruction for Installation and Use. Mountfield Export Team Email: export@mountfield.cz Mountfield a.s., Všechromy 56/Highway D1, Exit 15, 25163 Strančice, Czech Republic www.mountfield-export.com PRICES IN €, EXW Prague - Czech Republic /PREISE IN €, EXW Prag - Tschechische Republik...
Need help?
Do you have a question about the ROWEN and is the answer not in the manual?