Diagnostics And Service Soft Switch - Sharp UX-470 Service Manual

Hide thumbs Also See for UX-470:
Table of Contents

Advertisement

UX-470ES/SE/AT
FO-880ES/AT

[2] Diagnostics and service soft switch

1. Operating procedure
(1) Entering the diagnostic mode
Press FUNC → 9 →
→ 8 → # → 7 , and the following display will appear.
ROM Ver. FLN0
(FMM0 , FMH0 , FLP0 , FMI0 ) After 2 sec: DIAG MODE
FLN0
(UX-470ES)
FMM0
(UX-470SE)
FMH0
(UX-470AT)
FLP0
(FO-880ES)
FMI0
(FO-880AT)
Then press the START key. Select the desired item with the
(Diag•specifications)
FUNC
9
8
If the diag mode cannot be set, repeat the diag mode operation, per-
forming the following operation.
After the power is turned on and "WAIT A MOMENT" is indicated, press
the STOP key.
2. Diagnostic items
ITEM
DIRECT
DIRECT
No.
key
key
(UX-470)
(FO-880)
1
1
1
2
2
2
3
3
3
4
4
4
5
5
5
6
6
7
7
8
8
9
10
11
12
13
14
FLN0
FMM0
7
FLP0
DIAG MODE
FMH0
FMI0
Soft switch mode
START
ROM & RAM check
START
Aging mode
START
Panel key test
START
Check pattern
START
Signal send mode
START
Memory clear
START
STOP
KEY
+
"Power ON"
Memory clear
(Work + Backup)
Contents
SOFT SWITCH MODE
Soft switches are displayed and changed. List can be output.
ROM & RAM CHECK
ROM is sum-checked, and RAM is matched. Result list is output.
AGING MODE
10 sheets of check patterns are output every 5 minutes per sheet.
PANEL KEY TEST
Panel keys are tested. Result list is output.
CHECK PATTERN
Check pattern is output.
SIGNAL SEND MODE
Various signals of FAX communication are output.
MEMORY CLEAR
Back-up memory is cleared, and is set at delivery.
SHADING MODE
Shading compensation is performed in this mode.
ALL BLACK PRINT
To check the print head, whole dots are printed over the interval of 2 m.
AUTO FEEDER MODE
Insertion and discharge of document are tested.
MESSAGE PRINT
The display message of each language is printed out together with the English equivalent.
RING & DIAL FREE
Allows CI detection of 13Hz or more. Eliminates dial tone detection in auto dial.
FLASH MEMORY CHECK
Checks flash memory write/read.
FLASH MEMORY CLEAR
Checks flash memory clearing.
key or the # key or select with the rapid key. Enter the mode with the START key.
START
1
2
3
4
5
6
7
START
In relation with the process response (request from Production
KEY
Engineering) "WAIT A MOMENT" clock indication may appear depending
on STOP key timing. If the STOP key is held down, "MEMORY CLEAR?"
appears.
2 – 2
Flash memory clear
START
START
Flash memory check
START
Ring & Dial free
START
Message print
Auto feeder mode
START
All black mode
START
Shading mode
8
START
Function