Page 3
FCC Caution. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Any Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
Page 4
INTRODUCTION TO REFRIGERANTS R32 Introduction to Refrigerants R32 The refrigerants used for air conditioners are environmentally friendly hydrocarbons R32. This kind of erant is combustible and odorless. Moreover, it can burn and explode under certain condition. However, there will be no risk of burning and explosion if you comply with the following table to install your air conditioner in a room with an appropriate area and use it correctly.
INSTALLATION & ASSEMBLY INSTRUCTIONS Important Considerations Before installing the appliance, you must read the manual carefully to get the safety information and notes. When filling the combustible refrigerant, any of your rude operations may cause serious injury or injuries to human body or bodies and object or objects. A leak test must be done after the installation is completed.
INSTALLATION & ASSEMBLY INSTRUCTIONS Introduction to Refrigerants R32 1. Site Safety Open Flames Prohibited Ventilation Necessary 2. Operation Safety Open Flames Prohibited Mind Static Electricity Must Wear Protective Clothing and anti-static gloves Don't use mobile phone 3. Installation Safety Refrigerant Leak Detector Appropriate Installation Location The left picture is the schematic diagram of a refrigerant leak detector.
Page 15
AUTO AUTO SPEED MODE TIMER ON: WHEN THE UNIT IS IN STANDBY, PRESS THE TIMER BUTTON TO SET THE TEMPERATURE, THEN PRESS THE TIMER BUTTON TO SET THE TIMER TO ON, AND PRESS " " AND " " BUTTON TO ADJUST THE SETTING TIME AS YOU NEED, AFTER THE DISPLAY IS STABLE, PRESS THE TIMER BUTTON TO CONFIRM.
PRESS THE SLEEP BUTTON, ALL OF THE DISPLAY LIGHTS WILL TURN OFF AFTER A WHILE, BUT THE SLEEP LIGHT IS ALWAYS ON. IN SLEEP MODE, THE AIR CONDITIONER WILL AUTOMATICALLY ADJUST THE TEMPERATURE AND FAN SPEED TO MAKE THE ROOM MORE COMFORTABLE DURING THE NIGHT. THE SET TEMPERATURE WILL AUTOMATICALLY RAISE EVERY 30-60 MINUTES, AND AT MOST CHANGE SIXTIMES UNTIL THE SET TEMPERATURE IS 81 OR 82 .
Page 17
PRESS THE SLEEP BUTTON, ALL OF THE DISPLAY LIGHTS WILL TURN OFF AFTER A WHILE, BUT THE SLEEP LIGHT IS ALWAYS ON. IN SLEEP MODE, THE AIR CONDITIONER WILL AUTOMATICALLY ADJUST THE TEMPERATURE AND FAN SPEED TO MAKE THE ROOM MORE COMFORTABLE DURING THE NIGHT.
Need help?
Do you have a question about the CL-RAC08EWIES and is the answer not in the manual?
Questions and answers