GENERAL INSTRUCTIONS

These instructions should be read carefully and retained after installation by the end user for
future reference and maintenance.
These instructions should be used to aid installation of the following products:
EX003T / EX004T / EX005T

SAFETY

This product must be installed in accordance with the latest edition of the IEE Wirin
• This product must be installed in accordance with the latest edition of the IEE Wiring Regulations (BS7671)
(BS7671) and current Building Regulations. If in any doubt, consult a qualified elec
and current Building Regulations. If in any doubt, consult a qualified electrician
Please isolate mains prior to installation or maintenance
• Please isolate mains prior to installation or maintenance
Check the total load on the circuit (including when this product is fitted) does not ex
• Check the total load on the circuit (including when this product is fitted) does not exceed the rating of the
circuit cable, fuse or circuit breaker
the circuit cable, fuse or circuit breaker
• Please note the IP (Ingress Protection) rating of this product when deciding the location for installation
Please note the IP (Ingress Protection) rating of this product when deciding the loc
• This product is Class II double insulated
This product is Class II double insulated
• This product is IPX4 rated
This product is IPX4 rated

INSTALLATION

Note - If this product is being used in conjunction with an external PIR or sensor, please confirm with the
manufacturer of the sensors that they are compatible.
Provide power to the required point of installation
• Provide power to the required point of installation
Cut a suitable 100mm diameter hole in the mounting surface ensuring not to infring
• Cut a suitable 100mm diameter hole in the mounting surface ensuring not to infringe with any joists,
gas / water pipes or electrical cables. Install suitable ducting and a suitable externa
gas / water pipes or electrical cables. Install suitable ducting and a suitable external grille or shutter. The
The maximum length of ducting to be used is 2m
maximum length of ducting to be used is 2m
Remove the front fascia (see Fig. 1)
• Remove the front fascia (see Fig. 1)
Fig. 1
Fig. 1
Remove the faceplate by removing the screw at the bottom of the product and liftin
Mark the location of the fixing holes and drill ensuring not to infringe with any gas /
electrical cables
2
Remove the cable knock-out on the baseplate and guide the mains cable through