3. Entering and exiting the adjustment process mode
1) Before entering the adjustment process mode, the AV position RESET in the video adjustment menu.
2) At the state TV is turned on, touch the power key for 5seconds.
NOTE: Picture will disappear when you touch the power key, but keep touching the power key.
3) When the center icon LED blinks, release your finger from the power key.
4) Next, touch the "POWER" key with the "VOL (—)" and "INPUT" key touching.
TV will turn on and the letter "<K>" appears on the screen.
5) Next, touch the "VOL (—)" and "CH (
6) When the center icon LED turns on, release your finger from the keys.
(The "VOL (—)" and "CH (
Multiple lines of blue characters appearing on the display indicate that the unit is now in the adjustment process mode.
When you fail to enter the adjustment process mode (the display is the same as normal startup), retry the procedure.
7) To exit the adjustment process mode after the adjustment is done, unplug the AC cord from the outlet to make a forced shutdown. (When the
power was turned off with the remote controller, once unplug the AC cord and plug it again. In this case, wait 10 seconds or so before plugging.)
CAUTION: Use due care in handling the information described here lest your users should know how to enter the adjustment process mode. If the
settings are tampered in this mode, unrecoverable system damage may result.
4. Remote controller key operation and description of display in adjustment process mode
1) Key operation
Remote controller key
CH (
/
)
CH (
VOL (+/–)
VOL (+/–)
Cursor (UP/DOWN)
Cursor (LEFT/RIGHT)
INPUT
ENTER
*Input mode is switched automatically when relevant adjustment is started so far as the necessary input signal is available.
2) Description of display
(1) Current page/
Total pages
1/27
MAIN Version
BOOT Version
Monitor / Monitor BOOT Version
T-CON Version / LED CON Version
NETFLIX ESN
WIDEVINE DEVICE ID
FRC Version
TOUCH SENSOR/IR Micom Version
TEMPERATURE
LAMP ERROR
MONITOR ERR CAUSE
NORMAL STANDBY CAUSE
ERROR STANDBY CAUSE
)" keys at the same time.
)" keys should be pressed and held until the display appears.)
Main unit key
Moving an item (line) by one (UP/DOWN)
/
)
Changing a selected item setting (+1/ –1)
—————
Turing a page (PREVIOUS/NEXT)
—————
Changing a selected line setting (+10/ –10)
—————
Input switching (toggle switching)
—————
Executing a function
(2) Current selected input
INPUT4
1.04 (U 2010/07/07 1 A)
BSMKxxx
1.02 / 1.00
201006162D60250101 / FC
ERR
100531010000003D
201006162D60250101 / 010000000000000048
B0079022310 / 1.00
73
0
1) 11 B00000041:17
3) 11 B00000040:36
0
0
0
LC-40/46/52/60LE835U/830U/832U/LC-60LE831U
Function
(3) Current color system
(5) LCD Panel size/Speaker type
(4) Destination
AUTO
USA
60_UNDER
2) 11 B00000041:13
4) 11 B00000040:35
0
0
0
5 – 4
(6) Adjustment
process menu
header
(7) Parameters